1. Universal fluorescence nanoprobes to enhance the sensitivity of immunochromatographic assay for detection of 17β-estradiol in milk.
- Author
-
Lu, Xin, Ji, Jian, Li, Miao, Xu, Hongwen, Sun, Jiadi, Wang, Liping, Zhang, Yinzhi, and Sun, Xiulan
- Subjects
- *
IMMUNOGLOBULIN G , *RECOMBINANT proteins , *HIGH performance liquid chromatography , *MONOCLONAL antibodies , *FLUORESCENCE , *QUANTUM dots - Abstract
• A strategy was proposed to enhance sensitivity of immunochromatographic assay (ICA). • Two probes were constructed based on quantum dot nanobeads, protein A and anti-IgG antibody. • The probes are oriented to Fc region of anti-E2 antibody to fully expose Fab region. • The ICA based on universal probes achieved high-sensitivity and rapid detection of E2 in milk. • The prepared universal probes could be applied for the detection of any antigen per strip. The pollution caused by estrogens in the environment and food has received increasing attention. It is still challenging for on-site immunochromatographic assay (ICA) detection of estrogens. The performance of the prepared probes plays a decisive role in the sensitivity and stability of the ICA system. The published probes usually directly couple the detection antibody to the label, ignoring the influence of the label on the activity of the antibody. In this study, 17β-estradiol (E 2) was used as a model analyte for the ICA system. Two universal probes were constructed based on quantum dot nanobeads (QBs), recombinant protein A (SPA, from Staphylococcus aureus), and rabbit anti-mouse immunoglobulin G antibody (anti-IgG). The probes were prepared by coupling QBs with SPA, releasing anti-E 2 monoclonal antibody (mAb), and maintaining its activity. The prepared universal probes can orient recognize the Fc region of mAb and fully expose its Fab region, improving the detection sensitivity of the ICA system. The free anti-E 2 mAb and the universal probe (QBs@SPA or QBs@SPA@anti-IgG) were used as the detection antibodies and signal donors, respectively. The results show that the proposed ICA based on QBs@SPA and QBs@SPA@anti-IgG probes could detect E 2 with IC 50 of 8.83 and 0.93 ng/mL, respectively, within 15 min under optimal conditions. The recovery results of ICA based on QBs@SPA and QBs@SPA@anti-IgG probes showed good agreement with the findings of the high-performance liquid chromatography (HPLC) analysis for spiked samples. The developed ICA system based on universal probes was superior in terms of sensitivity, rapidity, and applicability, and held great promise for its implementation in detecting environmental and food small-molecule pollutants. [ABSTRACT FROM AUTHOR]
- Published
- 2022
- Full Text
- View/download PDF