7 results on '"Cambrodi R"'
Search Results
2. ID 426 – Nightmares as form of manifestation of brainstem glioma
- Author
-
Álvarez, N., García, B., Romero, O., and Cambrodí, R.
- Published
- 2016
- Full Text
- View/download PDF
3. The prevalence of narcolepsy in Catalunya (Spain).
- Author
-
Tió E, Gaig C, Giner-Soriano M, Romero O, Jurado MJ, Sansa G, Pujol M, Sans O, Álvarez-Guerrico I, Caballol N, Jimenez M, Becerra JL, Escartin A, Monasterio C, Molins A, Bove A, Viña J, Iranzo A, Cambrodi R, Calvo G, Morros R, and Santamaria J
- Subjects
- Adolescent, Adult, Aged, Aged, 80 and over, Child, Female, Humans, Male, Middle Aged, Prevalence, Spain, Young Adult, Narcolepsy diagnosis
- Abstract
Previous studies have estimated an overall prevalence for narcolepsy between 15 and 70 cases per 100 000 inhabitants. We aimed to estimate the prevalence of narcolepsy in Catalunya (Catalonia), a north-east region of Spain (7 424 754 inhabitants), on 31 December 2014 by identifying all living subjects diagnosed with narcolepsy. First, we identified patients diagnosed by one of the 13 sleep, paediatric or neurological departments that perform tests regularly to diagnose narcolepsy. In a second phase, we searched for additional patients with narcolepsy in a clinical database of the primary health-care system. Clinical files were reviewed and narcolepsy diagnosis validated according to the Brighton Collaboration case definitions. Three hundred and twenty-five patients had a validated diagnosis of narcolepsy in the specialized centres (mean age: 44.6 years, range: 6-89; male: 60.3%; 85% with narcolepsy type 1), including 17.8% cases in Brighton, definition level 1, 62.5% in level 2, 15.4% in level 3 and 4.3% in level 4a. The overall prevalence for narcolepsy was 4.4; 3.7 for narcolepsy type 1 and 0.7 cases per 100 000 inhabitants for narcolepsy type 2. Fifty-six additional narcoleptic patients were identified in the primary health-care system, increasing the overall prevalence to 5.2 cases per 100 000 inhabitants. Prevalence rates for narcolepsy type 1 increased from childhood to adulthood, but in subjects aged more than 50 years there was a substantial drop in prevalence rates, suggesting the presence of a significant pool of undiagnosed cases in this population. Narcolepsy can be considered a rare neurological disorder in Catalunya., (© 2017 European Sleep Research Society.)
- Published
- 2018
- Full Text
- View/download PDF
4. Adaptive Servoventilation Device Software in the Assessment of Residual Respiratory Events in Patients With Central or Complex Apnoeas.
- Author
-
Silveira MG, Sampol G, Cambrodi R, Ferre À, and Lloberes P
- Subjects
- Aged, Calibration, Cheyne-Stokes Respiration therapy, Female, Humans, Male, Middle Aged, Sleep Apnea, Central therapy, Cheyne-Stokes Respiration diagnosis, Continuous Positive Airway Pressure instrumentation, Sleep Apnea, Central diagnosis, Software
- Published
- 2017
- Full Text
- View/download PDF
5. Sleep quality and daytime sleepiness in patients treated with adjunctive perampanel for focal seizures.
- Author
-
Toledo M, Gonzalez-Cuevas M, Miró-Lladó J, Molins-Albanell A, Falip M, Martinez AB, Fernandez S, Quintana M, Cambrodi R, Santamarina E, and Salas-Puig J
- Subjects
- Adolescent, Adult, Aged, Anticonvulsants therapeutic use, Female, Humans, Male, Middle Aged, Nitriles, Prospective Studies, Pyridones therapeutic use, Young Adult, Anticonvulsants adverse effects, Pyridones adverse effects, Seizures drug therapy, Sleep Wake Disorders chemically induced
- Abstract
Purpose: The purpose of this study was to evaluate subjective sleep quality and daytime sleepiness in patients receiving adjunctive perampanel for focal seizures., Methods: We conducted a multicenter, prospective, interventional, open-label study in patients aged >16 with focal seizures who received adjunctive perampanel (flexible dosing: 2-12mg). Sleep quality was assessed with the Pittsburgh Sleep Quality Index (PSQI) and daytime sleepiness with the Epworth Sleepiness Scale (ESS) at baseline and 3 and 6months after initiating perampanel. Patients with modifications in their baseline AEDs or sleep medications were excluded., Results: In 72 patients with drug-resistant focal seizures, mean baseline PSQI score (±standard deviation) was 7.26 (±4.6), and ESS was 6.19 (±4.2). At 3months (median perampanel dose: 4mg), there was no significant mean change from baseline in ESS score (n=61) and a significant improvement in PSQI (-1.51 points; n=44; p=0.007), driven mainly by improved sleep efficiency (p=0.012). In the 31 patients with 6-month data, ESS (but not PSQI) improved significantly at 6months vs baseline (p=0.029). The only factor significantly correlated with sleep parameters was number of baseline AEDs (higher number correlated with worse daytime sleepiness). Seizure frequency was reduced significantly from baseline at 3 and 6months. In bivariate analysis, neither PSQI nor ESS was associated with seizure frequency, suggesting that the changes in daytime sleepiness and sleep quality may be independent of the direct effect on seizures., Conclusion: Adjunctive perampanel did not worsen sleep quality or daytime sleepiness at 3months and reduced daytime sleepiness in patients continuing perampanel for 6months. Perampanel may be a suitable AED in patients with sleep disorders, in addition to refractory focal seizures., (Copyright © 2016 Elsevier Inc. All rights reserved.)
- Published
- 2016
- Full Text
- View/download PDF
6. A Bayesian cost-effectiveness analysis of a telemedicine-based strategy for the management of sleep apnoea: a multicentre randomised controlled trial.
- Author
-
Isetta V, Negrín MA, Monasterio C, Masa JF, Feu N, Álvarez A, Campos-Rodriguez F, Ruiz C, Abad J, Vázquez-Polo FJ, Farré R, Galdeano M, Lloberes P, Embid C, de la Peña M, Puertas J, Dalmases M, Salord N, Corral J, Jurado B, León C, Egea C, Muñoz A, Parra O, Cambrodi R, Martel-Escobar M, Arqué M, and Montserrat JM
- Subjects
- Continuous Positive Airway Pressure methods, Cost-Benefit Analysis, Female, Follow-Up Studies, Humans, Male, Middle Aged, Patient Compliance statistics & numerical data, Prospective Studies, Quality of Life, Sleep, Sleep Apnea, Obstructive physiopathology, Sleep Apnea, Obstructive psychology, Telemedicine economics, Bayes Theorem, Continuous Positive Airway Pressure economics, Disease Management, Sleep Apnea, Obstructive therapy, Telemedicine methods
- Abstract
Background: Compliance with continuous positive airway pressure (CPAP) therapy is essential in patients with obstructive sleep apnoea (OSA), but adequate control is not always possible. This is clinically important because CPAP can reverse the morbidity and mortality associated with OSA. Telemedicine, with support provided via a web platform and video conferences, could represent a cost-effective alternative to standard care management., Aim: To assess the telemedicine impact on treatment compliance, cost-effectiveness and improvement in quality of life (QoL) when compared with traditional face-to-face follow-up., Methods: A randomised controlled trial was performed to compare a telemedicine-based CPAP follow-up strategy with standard face-to-face management. Consecutive OSA patients requiring CPAP treatment, with sufficient internet skills and who agreed to participate, were enrolled. They were followed-up at 1, 3 and 6 months and answered surveys about sleep, CPAP side effects and lifestyle. We compared CPAP compliance, cost-effectiveness and QoL between the beginning and the end of the study. A Bayesian cost-effectiveness analysis with non-informative priors was performed., Results: We randomised 139 patients. At 6 months, we found similar levels of CPAP compliance, and improved daytime sleepiness, QoL, side effects and degree of satisfaction in both groups. Despite requiring more visits, the telemedicine group was more cost-effective: costs were lower and differences in effectiveness were not relevant., Conclusions: A telemedicine-based strategy for the follow-up of CPAP treatment in patients with OSA was as effective as standard hospital-based care in terms of CPAP compliance and symptom improvement, with comparable side effects and satisfaction rates. The telemedicine-based strategy had lower total costs due to savings on transport and less lost productivity (indirect costs)., Trial Register Number: NCT01716676., (Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.)
- Published
- 2015
- Full Text
- View/download PDF
7. Clinical Validation of Adjusted Corneal Power in Patients with Previous Myopic Lasik Surgery.
- Author
-
Camps VJ, Piñero DP, Mateo V, García C, Artola A, Pérez-Cambrodi R, and Ruiz-Fortes P
- Abstract
Purpose. To validate clinically a new method for estimating the corneal power (P c ) using a variable keratometric index (n kadj) in eyes with previous laser refractive surgery. Setting. University of Alicante and Medimar International Hospital (Oftalmar), Alicante, (Spain). Design. Retrospective case series. Methods. This retrospective study comprised 62 eyes of 62 patients that had undergone myopic LASIK surgery. An algorithm for the calculation of n kadj was used for the estimation of the adjusted keratometric corneal power (P kadj). This value was compared with the classical keratometric corneal power (P k ), the True Net Power (TNP), and the Gaussian corneal power (P cGauss). Likewise, P kadj was compared with other previously described methods. Results. Differences between P cGauss and P c values obtained with all methods evaluated were statistically significant (p < 0.01). Differences between P kadj and P cGauss were in the limit of clinical significance (p < 0.01, loA [-0.33,0.60] D). Differences between P kadj and TNP were not statistically and clinically significant (p = 0.319, loA [-0.50,0.44] D). Differences between P kadj and previously described methods were statistically significant (p < 0.01), except with P cHaigisL (p = 0.09, loA [-0.37,0.29] D). Conclusion. The use of the adjusted keratometric index (n kadj) is a valid method to estimate the central corneal power in corneas with previous myopic laser refractive surgery, providing results comparable to P cHaigisL.
- Published
- 2015
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.