1. Signal analysis of voltage noise in welding arcs
- Author
-
Elis, E and Eagar, T. W
- Subjects
Mechanical Engineering - Abstract
Gas tungsten arc welds were made on low alloy steel plates to which intentional defects (discontinuities) were imposed. Disruption of shielding gas, welding over surface films, and tack welds produce changes in what is otherwise a relatively uniform voltage signal. The arc voltage was 15 volts + or - 2 volts with 300 mV ripple noise from the power supply. Changes in this steady noise voltage varied from 50 mV to less than one millivolt depending on the severity and the type of change experienced. In some instances the changes were easily detected by analysis of the signal in real time, while in other cases the signal had to transformed to the frequency domain in order to detect the changes. Discontinuities as small as 1.5 mm in length were detected. The ultimate sensitivity and reproducibility of the technique is still being investigated.
- Published
- 1982