8 results on '"Radiometal"'
Search Results
2. Editorial:Prof. Frank Rösch's legacy in the radiopharmaceutical chemistry field
- Author
-
Poulie, Christian B.M., Piel, Markus, Neumaier, Bernd, Ross, Tobias, Herth, Matthias, Poulie, Christian B.M., Piel, Markus, Neumaier, Bernd, Ross, Tobias, and Herth, Matthias
- Published
- 2023
3. Radiofármacos y tomografía por emisión de positrones
- Author
-
Molina Romo, Víctor Manuel, Universidad de Sevilla. Departamento de Química Física, Guerrero Jarava, Ana Gema, Molina Romo, Víctor Manuel, Universidad de Sevilla. Departamento de Química Física, and Guerrero Jarava, Ana Gema
- Abstract
En la actualidad la Tomografía por Emisión de Positrones (PET) es una de las pruebas radio diagnóstica más utilizada. Su alta sensibilidad hace que esta técnica sea muy empleada en el diagnóstico y estadificación de distintas neoplasias, así como para enfermedades neurológicas y cardiovasculares. El PET utiliza radiofármacos de distinta naturaleza, pues pueden ser radiometales, radiofármacos marcados con halógenos o radiofármacos no marcados con halógenos. El radiofármaco más empleado en la prueba PET es el 18F-FDG. Todos los radiofármacos empleados en PET tienen como característica común la emisión de positrones que, tras sucesivas colisiones, irán perdiendo energía y finalmente se aniquilan con un electrón el cual es utilizado para la detección en PET. El PET suele ir asociado a un TAC pues cada una de estas técnicas ofrece unas características distintas. El PET proporciona información funcional de tejido y el TAC una imagen de la densidad del mismo. Además, el TAC corrige la imagen de PET.
- Published
- 2020
4. Radiofármacos y tomografía por emisión de positrones
- Author
-
Molina Romo, Víctor Manuel, Universidad de Sevilla. Departamento de Química Física, Guerrero Jarava, Ana Gema, Molina Romo, Víctor Manuel, Universidad de Sevilla. Departamento de Química Física, and Guerrero Jarava, Ana Gema
- Abstract
En la actualidad la Tomografía por Emisión de Positrones (PET) es una de las pruebas radio diagnóstica más utilizada. Su alta sensibilidad hace que esta técnica sea muy empleada en el diagnóstico y estadificación de distintas neoplasias, así como para enfermedades neurológicas y cardiovasculares. El PET utiliza radiofármacos de distinta naturaleza, pues pueden ser radiometales, radiofármacos marcados con halógenos o radiofármacos no marcados con halógenos. El radiofármaco más empleado en la prueba PET es el 18F-FDG. Todos los radiofármacos empleados en PET tienen como característica común la emisión de positrones que, tras sucesivas colisiones, irán perdiendo energía y finalmente se aniquilan con un electrón el cual es utilizado para la detección en PET. El PET suele ir asociado a un TAC pues cada una de estas técnicas ofrece unas características distintas. El PET proporciona información funcional de tejido y el TAC una imagen de la densidad del mismo. Además, el TAC corrige la imagen de PET.
- Published
- 2020
5. Développement d’outils moléculaires pour la tomographie d’émission par positrons
- Author
-
Tremblay, Geneviève, Guérin, Brigitte, Tremblay, Geneviève, and Guérin, Brigitte
- Abstract
Résumé : L’imagerie TEP est une modalité puissante qui permet de suivre d’infimes concentrations de traceurs marqués pour la détection de cancers et d’autres pathologies. Il y a actuellement un intérêt croissant pour le développement de peptides comme outils diagnostiques et de traitement en oncologie. Cet intérêt se justifie entre autres par le fait que les peptides sont tolérants à la présence de chélateurs bifonctionnels ou de groupements prosthétiques pour le marquage avec divers radiométaux (64Cu, T1/2 = 12,7 h, 68Ga, T1/2 = 68 min, etc.) ou le 18F (T1/2 = 109,8 min) sans perte de leur activité biologique. L’objectif des travaux rapportés dans ce document était de développer des outils moléculaires innovateurs et efficaces qui facilitent le marquage de peptides pour l’imagerie TEP. Il s’agit spécifiquement d’un chélateur bifonctionnel et d’une méthode de conjugaison rapide et sélective de groupe prosthétique. Sur un volet, un chélateur bifonctionnel analogue de la lysine avec des ligands méthylhydroxamates a été synthétisé en solution par double bisalkylation. Les résultats préliminaires indiquent une faible chélation avec le Cu(II), mais sont à poursuivre avec les 68Ga et 89Zr. Pour le second volet de radiomarquage au 18F, les procédures synthétiques ont été optimisées en deux étapes, soient le marquage du groupe prothétique et sa conjugaison au peptide. Tout d’abord, des conditions de marquage par une réaction de SNAr en présence de 18F- ont été développées pour donner le groupe prosthétique 18F-thioester nécessaire à la conjugaison. Par la suite, sa conjugaison au peptide par la réaction de ligation chémosélective, ce qui implique trois étapes 1) une transthioestérification favorisée entre les groupements thioester et thiol des segments de peptides; 2) un réarrangement irréversible de l’intermédiaire thioester en N-(oxyalkyl)amide, suivi; 3) du clivage de l’auxiliaire. Par les présents travaux, il a été prouvé que la nouvelle méthodologie en un seul pot réac, PET is a powerful imaging modality that follows tiny labeled tracer concentrations for the detection of cancer and other pathologies. There currently is a growing interest for the development of peptides as diagnostic and treatment tools in oncology. This interest is justified by the fact that peptides are tolerant to the presence of bifunctionnal chelators or prosthetic groups for labeling with many radiometals (64Cu, T1/2 = 12,7 h, 68Ga, T1/2 = 68 min, etc.) or 18F (T1/2 = 109,8 min), without losing their biological activity. The objective of the work reported in this document was to develop innovative and efficient molecular tools that facilitate peptide labeling for PET imaging. Specifically, they are a bifunctionnal chelator and a fast and selective prosthetic group conjugation method. On the first aspect, a lysine analogue bifunctionnal chelator bearing methylhydroxamate ligands was synthesized in solution through a double bisalkylation. The preliminary results show a weak Cu(II) chelation, but they are to be pushed forward with 68Ga and 89Zr. On the second aspect of 18F radiolabeling, synthetic procedures were optimised for two steps, which are the prosthetic group’s labeling and its conjugation to the peptide. First, the labeling conditions for a SNAr reaction with 18F- were developed, to yield the necessary 18F-thioester prosthetic group. Then, its conjugation to the peptide by the chemical ligation reaction through its three steps 1) a favored transthioesterification between the thioester and thiol peptide segments; 2) an irreversible rearrangement of the thioester intermediate to a N-(oxyalkyl)amide, followed; 3) the auxiliary cleavage. By this work, it has been proven that the new one pot methodology accelerates the reaction and allows the 18F labeling of unprotected peptides, which limits secondary reactions and the number of post peptide labeling steps. The prosthetic group conjugation to both model compound and peptide takes place in 26-55
- Published
- 2017
6. Développement d’outils moléculaires pour la tomographie d’émission par positrons
- Author
-
Tremblay, Geneviève, Guérin, Brigitte, Tremblay, Geneviève, and Guérin, Brigitte
- Abstract
Résumé : L’imagerie TEP est une modalité puissante qui permet de suivre d’infimes concentrations de traceurs marqués pour la détection de cancers et d’autres pathologies. Il y a actuellement un intérêt croissant pour le développement de peptides comme outils diagnostiques et de traitement en oncologie. Cet intérêt se justifie entre autres par le fait que les peptides sont tolérants à la présence de chélateurs bifonctionnels ou de groupements prosthétiques pour le marquage avec divers radiométaux (64Cu, T1/2 = 12,7 h, 68Ga, T1/2 = 68 min, etc.) ou le 18F (T1/2 = 109,8 min) sans perte de leur activité biologique. L’objectif des travaux rapportés dans ce document était de développer des outils moléculaires innovateurs et efficaces qui facilitent le marquage de peptides pour l’imagerie TEP. Il s’agit spécifiquement d’un chélateur bifonctionnel et d’une méthode de conjugaison rapide et sélective de groupe prosthétique. Sur un volet, un chélateur bifonctionnel analogue de la lysine avec des ligands méthylhydroxamates a été synthétisé en solution par double bisalkylation. Les résultats préliminaires indiquent une faible chélation avec le Cu(II), mais sont à poursuivre avec les 68Ga et 89Zr. Pour le second volet de radiomarquage au 18F, les procédures synthétiques ont été optimisées en deux étapes, soient le marquage du groupe prothétique et sa conjugaison au peptide. Tout d’abord, des conditions de marquage par une réaction de SNAr en présence de 18F- ont été développées pour donner le groupe prosthétique 18F-thioester nécessaire à la conjugaison. Par la suite, sa conjugaison au peptide par la réaction de ligation chémosélective, ce qui implique trois étapes 1) une transthioestérification favorisée entre les groupements thioester et thiol des segments de peptides; 2) un réarrangement irréversible de l’intermédiaire thioester en N-(oxyalkyl)amide, suivi; 3) du clivage de l’auxiliaire. Par les présents travaux, il a été prouvé que la nouvelle méthodologie en un seul pot réac, PET is a powerful imaging modality that follows tiny labeled tracer concentrations for the detection of cancer and other pathologies. There currently is a growing interest for the development of peptides as diagnostic and treatment tools in oncology. This interest is justified by the fact that peptides are tolerant to the presence of bifunctionnal chelators or prosthetic groups for labeling with many radiometals (64Cu, T1/2 = 12,7 h, 68Ga, T1/2 = 68 min, etc.) or 18F (T1/2 = 109,8 min), without losing their biological activity. The objective of the work reported in this document was to develop innovative and efficient molecular tools that facilitate peptide labeling for PET imaging. Specifically, they are a bifunctionnal chelator and a fast and selective prosthetic group conjugation method. On the first aspect, a lysine analogue bifunctionnal chelator bearing methylhydroxamate ligands was synthesized in solution through a double bisalkylation. The preliminary results show a weak Cu(II) chelation, but they are to be pushed forward with 68Ga and 89Zr. On the second aspect of 18F radiolabeling, synthetic procedures were optimised for two steps, which are the prosthetic group’s labeling and its conjugation to the peptide. First, the labeling conditions for a SNAr reaction with 18F- were developed, to yield the necessary 18F-thioester prosthetic group. Then, its conjugation to the peptide by the chemical ligation reaction through its three steps 1) a favored transthioesterification between the thioester and thiol peptide segments; 2) an irreversible rearrangement of the thioester intermediate to a N-(oxyalkyl)amide, followed; 3) the auxiliary cleavage. By this work, it has been proven that the new one pot methodology accelerates the reaction and allows the 18F labeling of unprotected peptides, which limits secondary reactions and the number of post peptide labeling steps. The prosthetic group conjugation to both model compound and peptide takes place in 26-55
- Published
- 2017
7. 44gSc from metal calcium targets for PET
- Author
-
Severin, Gregory, Gagnon, K., Engle, J. W., Valdovinos, H. F., Barnhart, T. E., Lewis, Jason S., Severin, Gregory, Gagnon, K., Engle, J. W., Valdovinos, H. F., Barnhart, T. E., and Lewis, Jason S.
- Abstract
A low-cost and efficient method for producing pre-clinical scale quantities of 44gSc is presented. Production involves proton irradiation of natural unenriched calcium metal followed by rapid separation of radioscandium from the target using hydroxmate functionalized resin.© 2012 American Institute of Physics
- Published
- 2012
8. 44gSc from metal calcium targets for PET
- Author
-
Severin, Gregory, Gagnon, K., Engle, J. W., Valdovinos, H. F., Barnhart, T. E., Lewis, Jason S., Severin, Gregory, Gagnon, K., Engle, J. W., Valdovinos, H. F., Barnhart, T. E., and Lewis, Jason S.
- Abstract
A low-cost and efficient method for producing pre-clinical scale quantities of 44gSc is presented. Production involves proton irradiation of natural unenriched calcium metal followed by rapid separation of radioscandium from the target using hydroxmate functionalized resin.© 2012 American Institute of Physics
- Published
- 2012
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.