1. CIPM key comparison CCPR-K1.a.2017 for spectral irradiance 250 nm to 2500 nm. Final report
- Author
-
Khlevnoy, B. B. [0000-0001-9502-650X], Campos Acosta, Joaquín [0000-0001-6527-1440], Park, S. [0000-0001-9270-0183], Obein, G. [0000-0002-2577-6361], Valin, M. H. [0000-0003-1824-6175], Vissière, A. [0000-0001-9334-5400], Dai, C. [0000-0003-3417-0254], Yoon, H. [0000-0002-8999-9441], Zama, T. [0000-0002-3117-1000], Shitomi, H. [0000-0002-7164-0326], Gamouras, A. [0000-0003-0378-806X], Woods, D. J. [0000-0002-7394-1296], Khlevnoy, B. B., Solodilov, M. V., Kolesnikova, S. S., Otryaskin, D. A., Pons Aglio, Alicia, Campos Acosta, Joaquín, Shin, D. J., Park, S., Obein, G., Valin, M. H., Vissière, A., Dai, C., Wu, Z., Wang, Y., Li, L., Lin, Y., Yoon, H., Gibson, C., Liu, Y., Manson, P., Atkinson, E., Zama, T., Shitomi, H., Goodman, T., Servantes, W., Gamouras, A., Woods, D. J., Sperfeld, P., Pape, S., Khlevnoy, B. B. [0000-0001-9502-650X], Campos Acosta, Joaquín [0000-0001-6527-1440], Park, S. [0000-0001-9270-0183], Obein, G. [0000-0002-2577-6361], Valin, M. H. [0000-0003-1824-6175], Vissière, A. [0000-0001-9334-5400], Dai, C. [0000-0003-3417-0254], Yoon, H. [0000-0002-8999-9441], Zama, T. [0000-0002-3117-1000], Shitomi, H. [0000-0002-7164-0326], Gamouras, A. [0000-0003-0378-806X], Woods, D. J. [0000-0002-7394-1296], Khlevnoy, B. B., Solodilov, M. V., Kolesnikova, S. S., Otryaskin, D. A., Pons Aglio, Alicia, Campos Acosta, Joaquín, Shin, D. J., Park, S., Obein, G., Valin, M. H., Vissière, A., Dai, C., Wu, Z., Wang, Y., Li, L., Lin, Y., Yoon, H., Gibson, C., Liu, Y., Manson, P., Atkinson, E., Zama, T., Shitomi, H., Goodman, T., Servantes, W., Gamouras, A., Woods, D. J., Sperfeld, P., and Pape, S.
- Abstract
This report describes the Key Comparison of the Consultative Committee for Photometry and Radiometry CCPR-K1.a.2017 for Spectral Irradiance in the wavelength range of 250 nm to 2500 nm. Tungsten quartz halogen lamps of the FEL type (1000 W) were used as artefacts. Each participant used its own set of lamps. The star scheme of measurements was applied with the sequence participant - pilot - participant. Twelve National Metrology Institutes participated in the comparison. Each participant's measurement data were based on a totally independent spectral irradiance scale realisation. VNIIOFI (the Russian Federation) served as a pilot. The measurements were carried out from 2017 - 2020. The analysis of the comparison was performed following the step-by-step approach described in Appendix B of the Guidelines for CCPR Key Comparison Report Preparation (CCPR-G2 Rev.4). The key comparison reference values (KCRV) were calculated independently at each wavelength as the weighted means with cut-off. The measurement data of all participants were used for the KCRV excluding just a few outliers in the wavelength range of 1700 nm to 2500 nm. The relative uncertainties of the KCRV were minimal, 0.08 %, at the wavelengths of 900 nm to 1500 nm and increasing towards the limits of the spectral range up to 0.28 % at 250 nm and 0.20 % at 2500 nm. Consistency checks were satisfied at 17 of the 28 measured wavelengths, but failed at 11 wavelengths, mostly in the infrared range. For the latter wavelengths the Mandel-Paule method was applied resulting in an additional uncertainty that varied depending on wavelength from 0.11 % to 0.89 %. In general, the measurement uncertainties submitted by the participants in this comparison were less than those submitted in the previous CCPR-K1.a comparison. This is evidenced by the values of the cut-off, which had decreased at all wavelengths by a factor of 1.2 to 3.0 depending on wavelength. However, only for seven participants the degrees of equivalence
- Published
- 2023