130 results on '"Nicole V. Ruiter"'
Search Results
2. Single- PZT- Fiber Transducers for 3D Ultrasound Computed Tomography: Characterization and Modeling
- Author
-
Martin Angerer, Michael Zapf, Sylvia Gebhardt, and Nicole V. Ruiter
- Published
- 2022
- Full Text
- View/download PDF
3. Realization of an pseudo-randomly sampled 3D USCT
- Author
-
Michael Zapf, Torsten Hopp, Hartmut Gemmeke, Martin Angerer, Zewei Lu, Olga Molchanova, Nima Rashvand, Roberto Blanco, Petra Steck, Benjamin Leyrer, Denis Tcherniakhovski, Dietmar Bormann, Klaus Schlote-Holubek, and Nicole V. Ruiter
- Published
- 2022
- Full Text
- View/download PDF
4. Quality Control of Ultrasound Transducers using distribution-free Overlapping Coefficients
- Author
-
Martin Angerer, Michael Zapf, Martin Koch, and Nicole V. Ruiter
- Published
- 2021
- Full Text
- View/download PDF
5. Novel Front-End Design with High-voltage Transceiver ASICs for Ultrasound Computed Tomography
- Author
-
Michael Zapf, Zewei Lu, R. Blanco, Klaus Schlote-Holubek, Ivan Peric, Hartmut Gemmeke, and Nicole V. Ruiter
- Subjects
medicine.diagnostic_test ,Computer science ,Acoustics ,ComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISION ,High voltage ,Front and back ends ,Transducer ,Application-specific integrated circuit ,Transmission (telecommunications) ,Reflection (physics) ,medicine ,3D ultrasound ,ddc:620 ,Transceiver ,Engineering & allied operations - Abstract
3D Ultrasound Computed Tomography (USCT) is an imaging method for early breast cancer detection. The third generation 3 USCT device is developed at Karlsruhe Institute of Technology. The USCT III device has a hemispherical transducer distribution and emits and receives nearly spherical waves. This enables reflection and transmission imaging simultaneously and fully in 3D. The main challenges for the front-end design are to integrate a large number of transducers, to allow high voltage coded excitation, and to receive low amplitude signals with high quality. These challenges were solved using a smart sensor frontend design with a custom application specific integrated circuit (ASIC).
- Published
- 2021
- Full Text
- View/download PDF
6. Front Matter: Volume 11602
- Author
-
Nicole V. Ruiter and Brett Byram
- Subjects
business.industry ,Medical imaging ,Medicine ,Tomography ,business ,Ultrasonic imaging ,Biomedical engineering - Published
- 2021
- Full Text
- View/download PDF
7. Welcome and Introduction to SPIE Conference 11602
- Author
-
Brett Byram and Nicole V. Ruiter
- Subjects
medicine.medical_specialty ,Engineering ,business.industry ,medicine ,Medical imaging ,Medical physics ,Tomography ,business ,Ultrasonic imaging - Abstract
Welcome and Introduction to SPIE Medical Imaging conference 11602: Ultrasonic Imaging and Tomography
- Published
- 2021
- Full Text
- View/download PDF
8. Image registration between MRI and spot mammograms for X-ray guided stereotactic breast biopsy: preliminary results
- Author
-
Paola Clauser, Sarah Said, Nicole V. Ruiter, Pascal A. T. Baltzer, and Torsten Hopp
- Subjects
Breast biopsy ,medicine.medical_specialty ,Digital mammography ,medicine.diagnostic_test ,business.industry ,Image registration ,Magnetic resonance imaging ,medicine.disease ,Breast cancer ,Biopsy ,medicine ,Mammography ,Radiology ,ddc:620 ,business ,Contrast-enhanced Magnetic Resonance Imaging ,Engineering & allied operations - Abstract
Breast cancer is the most common cancer type among women. Approximately 40,000 women are expected to die from breast cancer every year. While digital mammography has a central role in the early diagnosis of breast cancer, many cancers are not visible in mammography, for example in women with dense breast tissue. Contrast enhanced magnetic resonance imaging (CE-MRI) of the breast is often used to detect lesions not visible in mammography. Lesions with suspicious characteristics on CE-MRI need to be further assessed with MRI-guided biopsy. However, MRI-guided biopsy is expensive, time consuming, and not widely available. In this paper, a novel method for a matching tool between MRI and spot mammograms is proposed. Our aim is to transfer information that is only visible in MRI onto mammographic spot projections, to enable X-ray guided biopsy even if the lesion is only visible in MRI. Two methods of registration in combination are used; a biomechanical model based registration between MRI and full view X-ray mammograms and a subsequent image based registration between full mammograms and spot mammograms. Preliminary results assessed for one patient from the Medical University of Vienna are presented. The target registration error (TRE) of biomechanical model based registration is 2.4 mm and the TRE of the image based registration is 9.5 mm. The total TRE of the two steps is 7.3 mm.
- Published
- 2021
- Full Text
- View/download PDF
9. Fast Image Reconstruction in Ultrasound Transmission Tomography by U-net
- Author
-
Xueze Qian, Jürgen Hesser, Nicole V. Ruiter, Hongjian Wang, Torsten Hopp, and Hartmut Gemmeke
- Subjects
Acceleration ,Speedup ,Pixel ,Artificial neural network ,Iterative method ,Computer science ,Noise reduction ,ComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISION ,Ultrasound transmission tomography ,Iterative reconstruction ,Algorithm - Abstract
Conventional iterative methods for image reconstruction in ultrasound transmission tomography need to perform many iterations where at each iteration one has to compute the complex forward model of ultrasound wave propagation, and hence they are time-consuming. We use a U-net neural network to accelerate the reconstruction, by training the network to map from an initial reconstruction obtained via a few iterations of L-BFGS method to the target ground truth image. Since the computation of a forward pass of the neural network is very fast, we can expect a significant acceleration using the trained network for image reconstruction. Experiments show that our trained network can replace 40 L-BFGS iterations to generate equivalent reconstructions with slightly better quantitative quality in terms of normalized root mean square error and better visual quality due to the network's denoising effect. It can achieve up to 283× speedup compared with L-BFGS method for reconstructing small-size sound speed images with 80×80 pixels. This implies that we can expect even greater acceleration effects when applying such approach to reconstruct large-size 3D images.
- Published
- 2020
- Full Text
- View/download PDF
10. Semi-Automated Packaging of Transducer Arrays for 3D Ultrasound Computer Tomography
- Author
-
Benjamin Leyrer, Michael Zapf, Martin Angerer, and Nicole V. Ruiter
- Subjects
Materials science ,medicine.diagnostic_test ,Adhesive bonding ,Aperture ,Acoustics ,02 engineering and technology ,021001 nanoscience & nanotechnology ,Electromagnetic interference ,030218 nuclear medicine & medical imaging ,03 medical and health sciences ,Printed circuit board ,0302 clinical medicine ,Transducer ,EMI ,medicine ,3D ultrasound ,0210 nano-technology ,Electrical impedance - Abstract
A semi-automated packaging process for transducer array manufacturing is presented. As an major innovation, a transducer disc is integrated in a sandwich structure between a printed circuit board (PCB) and an acoustic matching layer. Each of the transducer discs contains 18 lead-zirconium-titanate (PZT) fibres embedded in epoxy. To interconnect the transducer array components, adhesive bonding and automatic pick-and-place processes were used. A pre-series was evaluated by measuring the electro-mechanical impedance (EMI) before and after the assembly. Statistical analysis showed consistent behaviour of the series resonance f s and the electro-mechanical coupling k eff before and after the packaging. This encouraged the manufacturing of 256 arrays. These arrays will now be integrated in an ultrasound computer tomography (USCT) system with 3D scanning aperture for breast cancer imaging. With this system, we intend to bridge the gap towards clinical use of full 3D USCT.
- Published
- 2020
- Full Text
- View/download PDF
11. Enhanced KLM Model for Single-Fibre Piezocomposite Transducers
- Author
-
Sylvia Gebhardt, Nicole V. Ruiter, Michael Zapf, Holger Neubert, and Martin Angerer
- Subjects
010302 applied physics ,Physics ,Acoustics ,02 engineering and technology ,021001 nanoscience & nanotechnology ,01 natural sciences ,Piezoelectricity ,Vibration ,Resonator ,Transducer ,Dimension (vector space) ,Normal mode ,Transmission line ,0103 physical sciences ,0210 nano-technology ,Standard model (cryptography) - Abstract
The requirements of our third generation 3D ultrasound computer tomography system (USCT) led to a transducer array design based on single-fibre piezocomposites. The used piezoelectric ceramic fibres exhibit a thickness to diameter ratio of 4/3. This ratio results in a proximity of the dominant axial and lateral vibration resonances. The standard Krimholtz-Leedom-Matthaei (KLM) model considers only one spatial dimension. This limits the validity of the modelled predictions for our application. By adding a coupled transmission line in series to the axial resonator, the standard model can be extended to take additional spatial dimensions into account. Using model parameters from literature resulted in a low model-to-measurement fit. To enhance the prediction accuracy, a brute-force optimisation over four model parameters was conducted. With the optimal parameter set, a fit of 90.3% could finally be achieved. The necessary model parameter changes were found reasonable for the piezocomposite design. With the presented model enhancement it is now possible to consider both dominant vibration modes of our transducers.
- Published
- 2020
- Full Text
- View/download PDF
12. Front Matter: Volume 11319
- Author
-
Nicole V. Ruiter and Brett Byram
- Subjects
business.industry ,Medical imaging ,Medicine ,Tomography ,business ,Ultrasonic imaging ,Biomedical engineering - Published
- 2020
- Full Text
- View/download PDF
13. Fat ray ultrasound transmission tomography: preliminary experimental results with simulated data
- Author
-
Nicole V. Ruiter, Torsten Hopp, Pierre-Antoine Comby, and Franziska Zuch
- Subjects
Physics ,Ground truth ,Compressed sensing ,Fresnel zone ,Breast imaging ,Astrophysics::High Energy Astrophysical Phenomena ,Bent molecular geometry ,Ultrasound transmission tomography ,Acoustic wave equation ,Algorithm ,Synthetic data - Abstract
Ultrasound transmission tomography is a promising modality for breast cancer diagnosis. For image reconstruc- tion approximations to the acoustic wave equation such as straight or bent rays are commonly used due to their low computational complexity. For sparse apertures the coverage of the volume by rays is very limited, thereby requiring strong regularization in the inversion process. The concept of fat rays reduces the sparseness and includes the contributions to the measured signal originating from the first Fresnel zone. In this work we investi- gate the application of the fat ray concept to ultrasound transmission tomography. We implement a straight ray, bent ray and fat ray forward model. For the inversion process a least squares solver (LSQR), a simultaneous al- gebraic reconstruction technique (SART) and a compressive sensing based total variation minimization (TVAL3) is applied. The combination of forward models and inversion processes has been evaluated by synthetic data. TVAL3 outperforms SART and LSQR, especially for sparse apertures. The fat ray concept is able to decrease the error with respect to the ground truth compared to the bent ray method especially for SART and LSQR inversion, and especially for very sparse apertures.
- Published
- 2020
- Full Text
- View/download PDF
14. An Innovative Practical Automatic Segmentation of Ultrasound Computer Tomography Images Acquired from USCT System
- Author
-
Ashkan Tashk, Nicole V. Ruiter, and Torsten Hopp
- Subjects
Point spread function ,Data processing ,medicine.diagnostic_test ,Computer Networks and Communications ,Computer science ,business.industry ,Energy Engineering and Power Technology ,Binary number ,020207 software engineering ,02 engineering and technology ,Image segmentation ,Signal Processing ,0202 electrical engineering, electronic engineering, information engineering ,medicine ,Preprocessor ,020201 artificial intelligence & image processing ,Segmentation ,3D ultrasound ,Computer vision ,Computer Vision and Pattern Recognition ,Artificial intelligence ,Tomography ,Electrical and Electronic Engineering ,business - Abstract
A 3D ultrasound computer tomography (USCT) device with a nearly isotropic and spatially invariant 3D point spread function has been constructed at Institute for Data Processing and Electronic (IPE), Karlsruhe Institute of Technology (KIT). This device is currently applied in clinical studies for breast cancer screening. In this paper, a new method to develop an automated segmentation algorithm for USCT acquired images is proposed. The method employs distance regularized level set evolutionary (DRLSE) active contours along with surface fitting extrapolation and 3D binary mask generation for fully automatic segmentation outcome. In the first stage of the proposed algorithm, DRLSE is applied to those 3D USCT slice images which contain breast and are less affected by noise and ring artifacts named as Cat2. The DRLSE segmentation results are employed to extrapolate the rest of slice images known as Cat1. To overcome defectively segmented slice images, a 3D binary mask is generated out of USCT attenuation images. The 3D binary mask is multiplied by the DRLSE-based segmentation results to form finally segmented 3D USCT images. The method was tested on 12 clinical dataset images. According to F-measure criterion, the proposed method shows higher performance than the previously proposed semiautomatic segmentation one.
- Published
- 2018
- Full Text
- View/download PDF
15. 3D ultrasound computer tomography: Hardware setup, reconstruction methods and first clinical results
- Author
-
Nicole V. Ruiter, Michael Zapf, Hartmut Gemmeke, Torsten Hopp, and Clemens G. Kaiser
- Subjects
Physics ,Point spread function ,Nuclear and High Energy Physics ,medicine.medical_specialty ,Image fusion ,medicine.diagnostic_test ,business.industry ,02 engineering and technology ,Iterative reconstruction ,021001 nanoscience & nanotechnology ,01 natural sciences ,Imaging phantom ,Data acquisition ,0103 physical sciences ,medicine ,Medical physics ,3D ultrasound ,Computer vision ,Depth of field ,Tomography ,Artificial intelligence ,0210 nano-technology ,business ,010301 acoustics ,Instrumentation - Abstract
A promising candidate for improved imaging of breast cancer is ultrasound computer tomography (USCT). Current experimental USCT systems are still focused in elevation dimension resulting in a large slice thickness, limited depth of field, loss of out-of-plane reflections, and a large number of movement steps to acquire a stack of images. 3D USCT emitting and receiving spherical wave fronts overcomes these limitations. We built an optimized 3D USCT, realizing for the first time the full benefits of a 3D system. The point spread function could be shown to be nearly isotropic in 3D, to have very low spatial variability and fit the predicted values. The contrast of the phantom images is very satisfactory in spite of imaging with a sparse aperture. The resolution and imaged details of the reflectivity reconstruction are comparable to a 3 T MRI volume. Important for the obtained resolution are the simultaneously obtained results of the transmission tomography. The KIT 3D USCT was then tested in a pilot study on ten patients. The primary goals of the pilot study were to test the USCT device, the data acquisition protocols, the image reconstruction methods and the image fusion techniques in a clinical environment. The study was conducted successfully; the data acquisition could be carried out for all patients with an average imaging time of six minutes per breast. The reconstructions provide promising images. Overlaid volumes of the modalities show qualitative and quantitative information at a glance. This paper gives a summary of the involved techniques, methods, and first results.
- Published
- 2017
- Full Text
- View/download PDF
16. Front Matter: Volume 10955
- Author
-
Brett Byram and Nicole V. Ruiter
- Subjects
business.industry ,Medical imaging ,Medicine ,Tomography ,business ,Ultrasonic imaging ,Biomedical engineering - Published
- 2019
- Full Text
- View/download PDF
17. Experimental analysis of ray-based sound speed reconstruction algorithms for phase aberration corrected USCT SAFT imaging
- Author
-
Nicole V. Ruiter, Torsten Hopp, Franziska Zuch, Michael Zapf, and Hartmut Gemmeke
- Subjects
Phase aberration ,Optics ,business.industry ,Computer science ,Speed of sound ,business - Published
- 2019
- Full Text
- View/download PDF
18. High-Speed Medical Imaging in 3D Ultrasound Computer Tomography
- Author
-
Marc Weber, Ernst Kretzek, Matthias Birk, Nicole V. Ruiter, Jürgen Becker, and Peter Figuli
- Subjects
Signal processing ,medicine.diagnostic_test ,business.industry ,Computer science ,Ultrasound ,ComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISION ,02 engineering and technology ,Iterative reconstruction ,medicine.disease ,030218 nuclear medicine & medical imaging ,03 medical and health sciences ,0302 clinical medicine ,Breast cancer ,Data acquisition ,Computational Theory and Mathematics ,Hardware and Architecture ,Signal Processing ,0202 electrical engineering, electronic engineering, information engineering ,medicine ,Medical imaging ,020201 artificial intelligence & image processing ,3D ultrasound ,Tomography ,business ,Computer hardware - Abstract
A promising candidate for sensitive imaging of breast cancer is 3D Ultrasound Computer Tomography (3D USCT). So far its clinical applicability for diagnosis has been limited by the duration of the demanding image reconstruction. In this paper we investigate how signal processing and image reconstruction can be accelerated for diagnosis by using heterogeneous hardware. Additionally, the time and costs for real-time system for a future diagnosis and therapy device is estimated. Reusing the device's built-in FPGA-based data acquisition system (DAQ) through reconfiguration results in a speed-up by a factor of 7 for signal processing and by a factor of 2 for image reconstruction. Applying cutting-edge single FPGAs and GPUs, speed-ups by a factor of 10 (FPGA) and 6 (GPU) for signal processing and 15 (FPGA) and 37 (GPU) for image reconstruction were achieved compared to a recent quad-core Intel Core-i7 CPU. Using quad-core CPUs and a cluster of eight GPUs allowed us for the first time to calculate volumes in less than 30 min with an overall speed-up by a factor of 47, enabling a first clinical study. Based on these results we extrapolated that real-time reconstruction for a therapeutic 3D USCT will be possible in the year 2020 if the trend in density follows the ITRS roadmap.
- Published
- 2016
- Full Text
- View/download PDF
19. A Comparison of Biomechanical Models for MRI to Digital Breast Tomosynthesis 3D Registration
- Author
-
Nicole V. Ruiter, P. Cotic Smole, Clemens G. Kaiser, J. Krammer, and Torsten Hopp
- Subjects
Similarity (geometry) ,medicine.diagnostic_test ,business.industry ,Computer science ,Image registration ,Magnetic resonance imaging ,Digital Breast Tomosynthesis ,medicine.disease ,030218 nuclear medicine & medical imaging ,03 medical and health sciences ,0302 clinical medicine ,Breast cancer ,Metric (mathematics) ,medicine ,Mammography ,Computer vision ,Artificial intelligence ,business ,030217 neurology & neurosurgery ,Volume (compression) - Abstract
Increasing interest in multimodal breast cancer diagnosis has led to the development of methods for MRI to X-ray mammography registration. The severe breast deformation in X-ray mammography is often tackled by biomechanical models, yet there is no common consensus in literature about the required complexity of the deformation model and the simulation strategy. We present for the first time an automated patient-specific biomechanical model based image registration of MRI to digital breast tomosynthesis (DBT). DBT provides three-dimensional information of the compressed breast and as such drives the registration by a volume similarity metric. We compare different simulation strategies and propose a patient-specific optimization of simulation and model parameters. The average three-dimensional breast overlap measured by Dice coefficient of DBT and registered MRI improves for four analyzed subjects by including the estimation of unloaded state, simulation of gravity, and a concentrated pull force that mimics manual positioning of the breast on the plates from 88.1% for a mere compression simulation to 93.1% when including all our proposed simulation steps, whereas additional parameter optimization further increased the value to 94.4%.
- Published
- 2018
- Full Text
- View/download PDF
20. Bundling 3D- and 2D-based registration of MRI to x-ray breast tomosynthesis
- Author
-
Nicole V. Ruiter, Clemens G. Kaiser, J. Krammer, P. Cotic Smole, and Torsten Hopp
- Subjects
Similarity (geometry) ,medicine.diagnostic_test ,business.industry ,Computer science ,medicine ,Mammography ,Computer vision ,Breast deformation ,Artificial intelligence ,Digital Breast Tomosynthesis ,business ,Projection (set theory) ,Tomosynthesis - Abstract
Increasing interest in multimodal breast cancer diagnosis has led to the development of methods for MRI to X-ray mammography registration to provide direct correlation of modalities. The severe breast deformation in X-ray mammography is often tackled by biomechanical models, which however have not yet brought the registration accuracy to a clinically applicable level. We present a novel registration approach of MRI to X-ray tomosynthesis. Tomosynthesis provides three-dimensional information of the compressed breast and as such has the ability to open new possibilities in the registration of MRI and X-ray data. By bundling the 3D information from the tomosynthesis volume with the 2D projection images acquired at different measuring angles, we provide a correlation between the registration error in 3D and 2D and evaluate different 3D- and 2D-based similarity metrics to drive the optimization of the automated patient-specific registration approach. From the preliminary study of four analysed patients we found that the projected registration error is in general larger than the 3D error in case of small registration errors in the cranio-caudal direction. Although both image shape and intensitybased 2D similarity metrics showed a clear correlation with the 2D registration error at different projection angles, metrics that relied on the combined 2D and 3D information yielded in most of the cases the minimal registration error and as such had better performance than similarity metrics that rely only on the shape similarity of volumes.
- Published
- 2018
- Full Text
- View/download PDF
21. Experimental evaluation of straight ray and bent ray phase aberration correction for USCT SAFT imaging
- Author
-
Michael Zapf, Nicole V. Ruiter, Torsten Hopp, and Hartmut Gemmeke
- Subjects
Physics ,Bresenham's line algorithm ,business.industry ,Image quality ,030206 dentistry ,Iterative reconstruction ,01 natural sciences ,03 medical and health sciences ,0302 clinical medicine ,Optics ,Speed of sound ,0103 physical sciences ,Point (geometry) ,business ,010301 acoustics ,Image resolution ,Electrical impedance ,Fast marching method - Abstract
In Ultrasound computer tomography (USCT) Synthetic aperture focusing technique (SAFT) is often applied for reflectivity image reconstruction. Phase aberration correction is essential to cope with the large sound speed differences in water and the different human tissues. In this paper we compare two approaches for phase aberration correction: a straight ray approximation using the Bresenham algorithm (B-SAFT) and a bent ray approximating using a multi-stencil Fast Marching Method (FMM-SAFT). The analysis is carried out with simulated point scatterers and simulated phantoms to measure the effect on the image resolution and contrast. The method is additionally applied to experimental data. B-SAFT degrades the image resolution and contrast in cases of large sound speed differences of objects and if the reconstructed point is close to a boundary where a change in impedance is present. FMM-SAFT is able to recover the image quality in these cases if the sound speed distribution is known accurately and with high resolution. If these requirements cannot be met, B-SAFT proved to be more robust.
- Published
- 2018
- Full Text
- View/download PDF
22. Image fusion of Ultrasound Computer Tomography volumes with X-ray mammograms using a biomechanical model based 2D/3D registration
- Author
-
Nicole V. Ruiter, Neb Duric, and Torsten Hopp
- Subjects
Breast imaging ,Image registration ,Breast Neoplasms ,Health Informatics ,Models, Biological ,Multimodal Imaging ,Sensitivity and Specificity ,Pattern Recognition, Automated ,Imaging, Three-Dimensional ,Image Interpretation, Computer-Assisted ,Humans ,Medicine ,Mammography ,Computer Simulation ,Radiology, Nuclear Medicine and imaging ,Computer vision ,Image fusion ,Ground truth ,3d registration ,Modality (human–computer interaction) ,Radiological and Ultrasound Technology ,medicine.diagnostic_test ,business.industry ,X-Ray Film ,Reproducibility of Results ,Image Enhancement ,Computer Graphics and Computer-Aided Design ,Subtraction Technique ,Female ,Ultrasonic Tomography ,Ultrasonography, Mammary ,Computer Vision and Pattern Recognition ,Artificial intelligence ,business ,Algorithms - Abstract
Ultrasound Computer Tomography (USCT) is a promising breast imaging modality under development. Comparison to a standard method like mammography is essential for further development. Due to significant differences in image dimensionality and compression state of the breast, correlating USCT images and X-ray mammograms is challenging. In this paper we present a 2D/3D registration method to improve the spatial correspondence and allow direct comparison of the images. It is based on biomechanical modeling of the breast and simulation of the mammographic compression. We investigate the effect of including patient-specific material parameters estimated automatically from USCT images. The method was systematically evaluated using numerical phantoms and in-vivo data. The average registration accuracy using the automated registration was 11.9mm. Based on the registered images a method for analysis of the diagnostic value of the USCT images was developed and initially applied to analyze sound speed and attenuation images based on X-ray mammograms as ground truth. Combining sound speed and attenuation allows differentiating lesions from surrounding tissue. Overlaying this information on mammograms, combines quantitative and morphological information for multimodal diagnosis.
- Published
- 2015
- Full Text
- View/download PDF
23. Automatic segmentation and object classification with neural network for an airborne ultrasound imaging system
- Author
-
Grischan Erbacher, Till Steiner, Nicole V. Ruiter, and Wei Yap Tan
- Subjects
Computer science ,Segmentation-based object categorization ,business.industry ,Image quality ,ComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISION ,Scale-space segmentation ,Iterative reconstruction ,Image segmentation ,01 natural sciences ,Hough transform ,law.invention ,ComputingMethodologies_PATTERNRECOGNITION ,law ,Region of interest ,0103 physical sciences ,Segmentation ,Computer vision ,Artificial intelligence ,business ,010301 acoustics - Abstract
An airborne ultrasound imaging system was developed for reflection tomography. The ultrasound transducers surround the region of interest (ROI) in an arrangement optimized for maximum coverage and homogeneous distributed image quality. In this work, we developed a workflow for automatic segmentation and classification of objects in the reconstructed images. Our workflow can be applied for varying intensities of object edges with a local maxima based segmentation and a multi-parameter image reconstruction. The segmented regions are classified with a neural network, and the object localization was implemented with Generalized Hough Transform using a custom template for each classified object in the data set. A classification accuracy of 95% for six trained test objects and a localization accuracy of 5 mm were achieved.
- Published
- 2017
- Full Text
- View/download PDF
24. Automated breast segmentation in ultrasound computer tomography SAFT images
- Author
-
Nicole V. Ruiter, Michael Zapf, Hartmut Gemmeke, Torsten Hopp, W. Y. Tan, and W. You
- Subjects
Active contour model ,Vector flow ,business.industry ,Breast imaging ,Computer science ,Scale-space segmentation ,Image segmentation ,medicine.disease ,Breast cancer ,medicine ,Segmentation ,Computer vision ,Tomography ,Artificial intelligence ,business - Abstract
Ultrasound Computer Tomography (USCT) is a promising new imaging system for breast cancer diagnosis. An essential step before further processing is to remove the water background from the reconstructed images. In this paper we present a fully-automated image segmentation method based on three-dimensional active contours. The active contour method is extended by applying gradient vector flow and encoding the USCT aperture characteristics as additional weighting terms. A surface detection algorithm based on a ray model is developed to initialize the active contour, which is iteratively deformed to capture the breast outline in USCT reflection images. The evaluation with synthetic data showed that the method is able to cope with noisy images, and is not influenced by the position of the breast and the presence of scattering objects within the breast. The proposed method was applied to 14 in-vivo images resulting in an average surface deviation from a manual segmentation of 2.7 mm. We conclude that automated segmentation of USCT reflection images is feasible and produces results comparable to a manual segmentation. By applying the proposed method, reproducible segmentation results can be obtained without manual interaction by an expert.
- Published
- 2017
- Full Text
- View/download PDF
25. Time of flight interpolated synthetic aperture focusing technique
- Author
-
Michael Zapf, Ernst Kretzek, Torsten Hopp, Hartmut Gemmeke, and Nicole V. Ruiter
- Subjects
business.industry ,Computer science ,Image quality ,3D reconstruction ,ComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISION ,computer.software_genre ,01 natural sciences ,030218 nuclear medicine & medical imaging ,Reduction (complexity) ,03 medical and health sciences ,Time of flight ,0302 clinical medicine ,Data acquisition ,Voxel ,Speed of sound ,0103 physical sciences ,Computer vision ,Ultrasonic Tomography ,Artificial intelligence ,business ,010301 acoustics ,Algorithm ,computer ,Interpolation - Abstract
Synthetic Aperture Focusing Technique (SAFT) allows fast data acquisition and optimally focused images. The computational burden for 3D imaging is large as for each voxel the delay for each acquired A-scan has to be calculated, e.g. O(N5) for N3 voxels and N2 A-scans. For 3D reconstruction of objects which are large in terms of the wavelength, e.g. ≥ (100 λ)3, the computation of one volume takes several days on a current multicore PC. If the 3D distribution of the speed of sound is applied to correct the delays, the computation time increases further. In this work a time of flight interpolation based GPU implementation (TOFI-SAFT) is presented which accelerates our previous GPU implementation of speed of sound corrected SAFT by a factor of 7 to 16 min. with only minor reduction of image quality.
- Published
- 2017
- Full Text
- View/download PDF
26. Evaluation of performance and architectural efficiency of FPGAs and GPUs in the 40 and 28nm generations for algorithms in 3D ultrasound computer tomography
- Author
-
Nicole V. Ruiter, Matthias Birk, Matthias Balzer, and Juergen Becker
- Subjects
Signal processing ,General Computer Science ,Computer science ,Process (computing) ,Symmetric multiprocessor system ,Parallel computing ,Domain (software engineering) ,Control and Systems Engineering ,Medical imaging ,Benchmark (computing) ,Electrical and Electronic Engineering ,Graphics ,Field-programmable gate array ,Algorithm - Abstract
In heterogeneous computing, application developers have to identify the best-suited target platform from a variety of alternatives. In this work, we compare performance and architectural efficiency of Graphics Processing Units (GPUs) and Field Programmable Gate Arrays (FPGAs) for two algorithms taken from a novel medical imaging method named 3D ultrasound computer tomography. From the 40nm and 28nm generations, we use top-notch devices and those with similar power consumption values. For our two benchmark algorithms from the signal processing and imaging domain, the results show that if power consumption is not considered, the GPU and FPGA from the 40nm generation give both, a similar performance and efficiency per transistor. In the 28nm process, in contrast, the FPGA is superior to its GPU counterpart by 86% and 39%, depending on the algorithm. If power is limited, FPGAs outperform GPUs in each investigated case by at least a factor of four.
- Published
- 2014
- Full Text
- View/download PDF
27. GPU-based iterative transmission reconstruction in 3D ultrasound computer tomography
- Author
-
Nicole V. Ruiter, Robin Dapp, Matthias Birk, and Jürgen Becker
- Subjects
Speedup ,medicine.diagnostic_test ,Computer Networks and Communications ,Computer science ,ComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISION ,Volume (computing) ,Parallel computing ,medicine.disease ,Theoretical Computer Science ,Computational science ,Breast cancer ,Transmission (telecommunications) ,Artificial Intelligence ,Hardware and Architecture ,medicine ,Ultrasound imaging ,3D ultrasound ,Ultrasonic Tomography ,Tomography ,Software ,ComputingMethodologies_COMPUTERGRAPHICS - Abstract
As today's standard screening methods frequently fail to detect breast cancer before metastases have developed, early diagnosis is still a major challenge. With the promise of high-quality volume images, three-dimensional ultrasound computer tomography is likely to improve this situation, but has high computational needs. In this work, we investigate the acceleration of the ray-based transmission reconstruction by a GPU-based implementation of the iterative numerical optimization algorithm TVAL3. We identified the regular and transposed sparse-matrix-vector multiply as the performance limiting operations. For accelerated reconstruction we propose two different concepts and devise a hybrid scheme as optimal configuration. In addition we investigate multi-GPU scalability and derive the optimal number of devices for our two primary use-cases: a fast preview mode and a high-resolution mode. In order to achieve a fair estimation of the speedup, we compare our implementation to an optimized CPU version of the algorithm. Using our accelerated implementation we reconstructed a preview 3D volume with 24,576 unknowns, a voxel size of (8?mm)3 and approximately 200,000 equations in 0.5?s. A high-resolution volume with 1,572,864 unknowns, a voxel size of (2mm)3 and approximately 1.6 million equations was reconstructed in 23?s. This constitutes an acceleration of over one order of magnitude in comparison to the optimized CPU version. We accelerate a ray-based 3D ultrasound CT reconstruction by GPU processing.By use-case optimized SpMV variants a speedup of one order of magnitude is obtained.We derive the optimal number of GPUs for reconstructions that do not fit on one GPU.A 3D-preview is reconstructed in 0.5 s, a high-resolution volume in 23 s.
- Published
- 2014
- Full Text
- View/download PDF
28. Automatic multimodal 2D/3D breast image registration using biomechanical FEM models and intensity-based optimization
- Author
-
Nicole V. Ruiter, P. Kreisel, Werner A. Kaiser, Hartmut Gemmeke, Matthias Dietzel, Pascal A. T. Baltzer, and Torsten Hopp
- Subjects
Similarity (geometry) ,Computer science ,Breast imaging ,Finite Element Analysis ,Image registration ,Breast Neoplasms ,Health Informatics ,Models, Biological ,Sensitivity and Specificity ,Pattern Recognition, Automated ,Imaging, Three-Dimensional ,Image Interpretation, Computer-Assisted ,medicine ,Humans ,Mammography ,Computer Simulation ,Radiology, Nuclear Medicine and imaging ,Computer vision ,Radiological and Ultrasound Technology ,medicine.diagnostic_test ,business.industry ,Reproducibility of Results ,Magnetic resonance imaging ,Image Enhancement ,Computer Graphics and Computer-Aided Design ,Finite element method ,Subtraction Technique ,Female ,Computer Vision and Pattern Recognition ,Artificial intelligence ,business ,Algorithms ,Volume (compression) ,Curse of dimensionality - Abstract
Due to their different physical origin, X-ray mammography and Magnetic Resonance Imaging (MRI) provide complementary diagnostic information. However, the correlation of their images is challenging due to differences in dimensionality, patient positioning and compression state of the breast. Our automated registration takes over part of the correlation task. The registration method is based on a biomechanical finite element model, which is used to simulate mammographic compression. The deformed MRI volume can be compared directly with the corresponding mammogram. The registration accuracy is determined by a number of patient-specific parameters. We optimize these parameters--e.g. breast rotation--using image similarity measures. The method was evaluated on 79 datasets from clinical routine. The mean target registration error was 13.2mm in a fully automated setting. On basis of our results, we conclude that a completely automated registration of volume images with 2D mammograms is feasible. The registration accuracy is within the clinically relevant range and thus beneficial for multimodal diagnosis.
- Published
- 2013
- Full Text
- View/download PDF
29. Automated Multimodal Breast CAD Based on Registration of MRI and Two View Mammography
- Author
-
P. Cotic Smole, Nicole V. Ruiter, and Torsten Hopp
- Subjects
medicine.medical_specialty ,medicine.diagnostic_test ,Pixel ,business.industry ,Computer science ,Image registration ,CAD ,Pattern recognition ,medicine.disease ,computer.software_genre ,Cad system ,030218 nuclear medicine & medical imaging ,03 medical and health sciences ,0302 clinical medicine ,Breast cancer ,Voxel ,Computer-aided diagnosis ,030220 oncology & carcinogenesis ,medicine ,Mammography ,Artificial intelligence ,Radiology ,business ,computer - Abstract
Computer aided diagnosis (CAD) of breast cancer is mainly focused on monomodal applications. Here we present a fully automated multimodal CAD, which uses patient-specific image registration of MRI and two-view X-ray mammography. The image registration estimates the spatial correspondence between each voxel in the MRI and each pixel in cranio-caudal and mediolateral-oblique mammograms. Thereby we can combine features from both modalities. As a proof of concept we classify fixed regions of interest (ROI) into normal and suspect tissue. We investigate the classification performance of the multimodal classification in several setups against a classification with MRI features only. The average sensitivity of detecting suspect ROIs improves by approximately 2% when combining MRI with both mammographic views compared to MRI-only detection, while the specificity stays at a constant level. We conclude that automatically combining MRI and X-ray can enhance the result of a breast CAD system.
- Published
- 2017
- Full Text
- View/download PDF
30. Automatic optimization of sensor positioning for an airborne ultrasound imaging system
- Author
-
Wei Yap Tan, Nicole V. Ruiter, and Till Steiner
- Subjects
Computer science ,business.industry ,010401 analytical chemistry ,ComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISION ,020206 networking & telecommunications ,Image processing ,02 engineering and technology ,Iterative reconstruction ,Object (computer science) ,01 natural sciences ,0104 chemical sciences ,Homogeneous ,0202 electrical engineering, electronic engineering, information engineering ,Ultrasound imaging ,ComputerSystemsOrganization_SPECIAL-PURPOSEANDAPPLICATION-BASEDSYSTEMS ,Ultrasonic sensor ,Computer vision ,Artificial intelligence ,business - Abstract
Airborne ultrasonic sensors are widely used in industry for detecting movement of targets and measuring their distances to the sensor. More complex object localization is usually done with optical systems, yet their application is limited. In this work an airborne ultrasound imaging system is developed, which reconstructs an image of the region-of-interest (ROI) with multiple objects. With further image processing, this system allows more sophisticated object localization. The proposed optimization method results in a sensor system with minimum number of sensors and improved sensor distribution for maximum coverage of the ROI and homogeneous performance.
- Published
- 2016
- Full Text
- View/download PDF
31. Wave equation based transmission tomography
- Author
-
Jürgen Hesser, Lea Althaus, Jana Mayer, Herbert Egger, Nicole V. Ruiter, Hartmut Gemmeke, Torsten Hopp, Michael Zapf, and Koen W. A. van Dongen
- Subjects
Physics ,Helmholtz equation ,business.industry ,Attenuation ,Mathematical analysis ,Paraxial approximation ,Iterative reconstruction ,Wave equation ,01 natural sciences ,Imaging phantom ,03 medical and health sciences ,0302 clinical medicine ,Optics ,030220 oncology & carcinogenesis ,Speed of sound ,0103 physical sciences ,Tomography ,business ,010301 acoustics - Abstract
For iterative image reconstruction of transmission tomography we apply the paraxial approximation of the Helmholtz equation for a spherical transducer arrangement. We choose this approach due to its three order of magnitude lower complexity than full wave solutions with the same precision for transmission tomography. In homogeneous media we prove that our forward solution is exact. With the help of this forward solution 2D and 3D ultrasound measurements could be simulated for transmission tomography. 2D reconstructions of a breast-like numerical phantom had a deviation in sound speed of 0.14 m/s and a deviation in attenuation of 6.5% from the ground truth. Applications up to now are breast cancer diagnostics and non-destructive testing.
- Published
- 2016
- Full Text
- View/download PDF
32. Temperature model for 3D ultrasound computer tomography
- Author
-
Michael Zapf, A. Menshikov, and Nicole V. Ruiter
- Subjects
medicine.diagnostic_test ,Computer science ,business.industry ,Aperture ,Electrical engineering ,medicine.disease ,Ultrasonic imaging ,Transducer ,Breast cancer ,medicine ,3D ultrasound ,Ultrasonic Tomography ,Tomography ,ddc:620 ,business ,Engineering & allied operations ,Computer hardware ,Reliability (statistics) - Abstract
A promising candidate for breast cancer imaging is ultrasound computer tomography (USCT). At Karlsruhe Institute of Technology (KIT) a 3D USCT with a semiellipsoidal aperture consisting of several hundreds of US transducers was built. The utilized imaging methods require accurate and reliable temperature information over the measured space and acquisition time. Several methods were applied which improved the temperature accuracy and reliability beyond the hardware defaults by one order of magnitude from ±1°C to approx. 0.005°C beyond the requirement of 0.1°C.
- Published
- 2016
- Full Text
- View/download PDF
33. Analysis of patient movement during 3D USCT data acquisition
- Author
-
Ernst Kretzek, Michael Zapf, Hartmut Gemmeke, Nicole V. Ruiter, and Torsten Hopp
- Subjects
medicine.diagnostic_test ,Computer science ,business.industry ,Movement (music) ,Aperture ,media_common.quotation_subject ,Image registration ,02 engineering and technology ,021001 nanoscience & nanotechnology ,01 natural sciences ,010309 optics ,Data acquisition ,0103 physical sciences ,medicine ,Contrast (vision) ,3D ultrasound ,Ultrasonic Tomography ,Computer vision ,Tomography ,Artificial intelligence ,Ultrasonography ,0210 nano-technology ,Nuclear medicine ,business ,media_common - Abstract
In our first clinical study with a full 3D Ultrasound Computer Tomography (USCT) system patient data was acquired in eight minutes for one breast. In this paper the patient movement during the acquisition was analyzed quantitatively and as far as possible corrected in the resulting images. The movement was tracked in ten successive reflectivity reconstructions of full breast volumes acquired during 10 s intervals at different aperture positions, which were separated by 41 s intervals. The mean distance between initial and final position was 2.2 mm (standard deviation (STD) ± 0.9 mm, max. 4.1 mm, min. 0.8 mm) and the average sum of all moved distances was 4.9 mm (STD ± 1.9 mm, max. 8.8 mm, min. 2.7 mm). The tracked movement was corrected by summing successive images, which were transformed according to the detected movement. The contrast of these images increased and additional image content became visible.
- Published
- 2016
- Full Text
- View/download PDF
34. 3D ultrasound computer tomography: update from a clinical study
- Author
-
J. Henrich, Michael Zapf, A. Tukalo, Hartmut Gemmeke, Nicole V. Ruiter, Torsten Hopp, Clemens G. Kaiser, J. Knaudt, and Ernst Kretzek
- Subjects
medicine.medical_specialty ,Computer science ,Breast imaging ,Aperture ,Image registration ,02 engineering and technology ,030218 nuclear medicine & medical imaging ,03 medical and health sciences ,0302 clinical medicine ,Breast cancer ,Data acquisition ,0202 electrical engineering, electronic engineering, information engineering ,medicine ,Medical physics ,3D ultrasound ,Computer vision ,Ground truth ,medicine.diagnostic_test ,business.industry ,Magnetic resonance imaging ,medicine.disease ,020201 artificial intelligence & image processing ,Ultrasonic Tomography ,Tomography ,Artificial intelligence ,Ultrasonography ,business - Abstract
Ultrasound Computer Tomography (USCT) is a promising new imaging method for breast cancer diagnosis. We developed a 3D USCT system and tested it in a pilot study with encouraging results: 3D USCT was able to depict two carcinomas, which were present in contrast enhanced MRI volumes serving as ground truth. To overcome severe differences in the breast shape, an image registration was applied. We analyzed the correlation between average sound speed in the breast and the breast density estimated from segmented MRIs and found a positive correlation with R=0.70. Based on the results of the pilot study we now carry out a successive clinical study with 200 patients. For this we integrated our reconstruction methods and image post-processing into a comprehensive workflow. It includes a dedicated DICOM viewer for interactive assessment of fused USCT images. A new preview mode now allows intuitive and faster patient positioning. We updated the USCT system to decrease the data acquisition time by approximately factor two and to increase the penetration depth of the breast into the USCT aperture by 1 cm . Furthermore the compute-intensive reflectivity reconstruction was considerably accelerated, now allowing a sub-millimeter volume reconstruction in approximately 16 minutes. The updates made it possible to successfully image first patients in our ongoing clinical study.
- Published
- 2016
- Full Text
- View/download PDF
35. Glasses for 3D ultrasound computer tomography: phase compensation
- Author
-
Nicole V. Ruiter, Torsten Hopp, and Michael Zapf
- Subjects
medicine.diagnostic_test ,010308 nuclear & particles physics ,business.industry ,Computer science ,Aperture ,Image quality ,Ultrasound ,medicine.disease ,01 natural sciences ,Transducer ,Breast cancer ,0103 physical sciences ,medicine ,3D ultrasound ,Computer vision ,Phase compensation ,Ultrasonic Tomography ,Tomography ,Artificial intelligence ,Ultrasonography ,business ,010301 acoustics ,Medical ultrasound - Abstract
Ultrasound Computer Tomography (USCT), developed at KIT, is a promising new imaging system for breast cancer diagnosis, and was successfully tested in a pilot study. The 3D USCT II prototype consists of several hundreds of ultrasound (US) transducers on a semi-ellipsoidal aperture. Spherical waves are sequentially emitted by individual transducers and received in parallel by many transducers. Reflectivity volumes are reconstructed by synthetic aperture focusing (SAFT). However, straight forward SAFT imaging leads to blurred images due to system imperfections. We present an extension of a previously proposed approach to enhance the images. This approach includes additional a priori information and system characteristics. Now spatial phase compensation was included. The approach was evaluated with a simulation and clinical data sets. An increase in the image quality was observed and quantitatively measured by SNR and other metrics.
- Published
- 2016
- Full Text
- View/download PDF
36. A comprehensive comparison of GPU- and FPGA-based acceleration of reflection image reconstruction for 3D ultrasound computer tomography
- Author
-
Matthias Balzer, Michael Zapf, Nicole V. Ruiter, Jürgen Becker, and Matthias Birk
- Subjects
medicine.diagnostic_test ,Computer science ,business.industry ,ComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISION ,Symmetric multiprocessor system ,Iterative reconstruction ,Computer graphics ,Pattern recognition (psychology) ,Medical imaging ,medicine ,Computer vision ,3D ultrasound ,Artificial intelligence ,Tomography ,business ,Field-programmable gate array ,Information Systems - Abstract
As today's standard screening methods frequently fail to diagnose breast cancer before metastases have developed, earlier breast cancer diagnosis is still a major challenge. Three-dimensional ultrasound computer tomography promises high-quality images of the breast, but is currently limited by a time-consuming image reconstruction. In this work, we investigate the acceleration of the image reconstruction by GPUs and FPGAs. We compare the obtained performance results with a recent multi-core CPU. We show that both architectures are able to accelerate processing, whereas the GPU reaches the highest performance. Furthermore, we draw conclusions in terms of applicability of the accelerated reconstructions in future clinical application and highlight general principles for speed-up on GPUs and FPGAs.
- Published
- 2012
- Full Text
- View/download PDF
37. Fusion of dynamic contrast-enhanced magnetic resonance mammography at 3.0T with X-ray mammograms: Pilot study evaluation using dedicated semi-automatic registration software
- Author
-
Pascal A. T. Baltzer, Nicole V. Ruiter, R Zoubi, W. A. Kaiser, Matthias Dietzel, Torsten Hopp, and Ingo B. Runnebaum
- Subjects
Gadolinium DTPA ,Scanner ,medicine.medical_specialty ,Contrast Media ,Image registration ,Breast Neoplasms ,Pilot Projects ,Standard deviation ,Imaging, Three-Dimensional ,Software ,Humans ,Medicine ,Mammography ,Radiology, Nuclear Medicine and imaging ,Aged ,Aged, 80 and over ,medicine.diagnostic_test ,business.industry ,Gadodiamide ,Magnetic resonance imaging ,General Medicine ,Middle Aged ,Image Enhancement ,Magnetic Resonance Imaging ,Confidence interval ,Female ,Radiology ,business ,Nuclear medicine ,Algorithms ,medicine.drug - Abstract
Rationale and objectives To evaluate the semi-automatic image registration accuracy of X-ray-mammography (XR-M) with high-resolution high-field (3.0 T) MR-mammography (MR-M) in an initial pilot study. Material and methods MR-M was acquired on a high-field clinical scanner at 3.0 T (T1-weighted 3D VIBE ± Gd). XR-M was obtained with state-of-the-art full-field digital systems. Seven patients with clearly delineable mass lesions >10 mm both in XR-M and MR-M were enrolled (exclusion criteria: previous breast surgery; surgical intervention between XR-M and MR-M). XR-M and MR-M were matched using a dedicated image-registration algorithm allowing semi-automatic non-linear deformation of MR-M based on finite-element modeling. To identify registration errors (RE) a virtual craniocaudal 2D mammogram was calculated by the software from MR-M (with and w/o Gadodiamide/Gd) and matched with corresponding XR-M. To quantify REs the geometric center of the lesions in the virtual vs. conventional mammogram were subtracted. The robustness of registration was quantified by registration of X-MRs to both MR-Ms with and w/o Gadodiamide. Results Image registration was performed successfully for all patients. Overall RE was 8.2 mm (1 min after Gd; confidence interval/CI: 2.0–14.4 mm, standard deviation/SD: 6.7 mm) vs. 8.9 mm (no Gd; CI: 4.0–13.9 mm, SD: 5.4 mm). The mean difference between pre- vs. post-contrast was 0.7 mm (SD: 1.9 mm). Conclusion Image registration of high-field 3.0 T MR-mammography with X-ray-mammography is feasible. For this study applying a high-resolution protocol at 3.0 T, the registration was robust and the overall registration error was sufficient for clinical application.
- Published
- 2011
- Full Text
- View/download PDF
38. FPGA-Based Embedded Signal Processing for 3-D Ultrasound Computer Tomography
- Author
-
Matthias Birk, Matthias Balzer, Nicole V. Ruiter, Jürgen Becker, Michael Huebner, and S. Koehler
- Subjects
Nuclear and High Energy Physics ,Signal processing ,Data processing ,Engineering ,business.industry ,Iterative reconstruction ,Set (abstract data type) ,Data set ,Data acquisition ,Nuclear Energy and Engineering ,Gate array ,Electronic engineering ,Electrical and Electronic Engineering ,Field-programmable gate array ,business ,Computer hardware - Abstract
A three-dimensional ultrasound computer tomography (3-D USCT) system for early breast cancer diagnosis is currently being developed at Institute for Data Processing and Electronics (IPE) at Karlsruhe Institute of Technology, Karlsruhe, Germany. A field-programmable gate array (FPGA)-based data acquisition (DAQ) system is used to acquire the measurement data. Over 3.5 million data sets are recorded for each breast, resulting in 20 GB of raw data. The data is subsequently transferred to a PC for time-consuming image reconstruction, which is in the order of days. A promising approach in reducing reconstruction time is mapping further computation to the FPGAs in the DAQ system. This paper covers the investigation of FPGA-based processing for a set of signal processing algorithms. In the best suited approach, processing time per data set is approximately 50 μs, occupying less than 30% of device resources.
- Published
- 2011
- Full Text
- View/download PDF
39. 2D/3D image fusion of X-ray mammograms with breast MRI: visualizing dynamic contrast enhancement in mammograms
- Author
-
Pascal A. T. Baltzer, Matthias Dietzel, Nicole V. Ruiter, Torsten Hopp, and Werner A. Kaiser
- Subjects
Adult ,medicine.medical_specialty ,Biomedical Engineering ,Contrast Media ,Breast Neoplasms ,Health Informatics ,Diagnosis, Differential ,Imaging, Three-Dimensional ,Breast cancer ,medicine ,Humans ,Mammography ,Breast MRI ,Radiology, Nuclear Medicine and imaging ,Medical physics ,skin and connective tissue diseases ,Aged ,Image fusion ,medicine.diagnostic_test ,business.industry ,Reproducibility of Results ,Cancer ,General Medicine ,Middle Aged ,medicine.disease ,Magnetic Resonance Imaging ,Computer Graphics and Computer-Aided Design ,Computer Science Applications ,Dynamic contrast ,3d image ,Dynamic contrast-enhanced MRI ,Female ,Surgery ,Computer Vision and Pattern Recognition ,Radiology ,business - Abstract
Breast cancer is the most common cancer among women. The established screening method to detect breast cancer is X-ray mammography. Additionally, MRI is used for diagnosis in clinical routine. Due to complementary diagnostic information, both modalities are often read in combination. Yet, the correlation is challenging due to different dimensionality of images and different patient positioning. In this paper, we describe a method to fuse X-ray mammograms with DCE-MRI. The present study was conducted to evaluate the feasibility of the approach.For the combination of information from both modalities, the images have to be registered using a compression simulation based on a patient-specific biomechanical model. The registered images can be compared directly. The contrast enhancement in the DCE-MRI volume is evaluated using parametric enhancement maps. A projection image of the contrast enhancement is created. The image fusion combines it with X-ray mammograms for intuitive multimodal diagnosis.The image fusion was evaluated using 11 clinical datasets. For 10 of 11 datasets, a good accuracy of the image registration was achieved. The overlap of contrast-enhanced regions with marked lesions in the mammogram is 61%. Lesions are clearly differentiable from surrounding tissue by the DCE-MRI projection in 10 of 11 cases.The described preliminary results are promising, thus we expect the visualization of quantitative information from dynamic MRI together with mammograms to be beneficial for multimodal diagnosis. Because of the use of clinical standard modalities, no additional image acquisition is needed.
- Published
- 2011
- Full Text
- View/download PDF
40. Development of Single-Fiber Piezocomposite Transducers for 3-D Ultrasound Computer Tomography
- Author
-
Sylvia E. Gebhardt, Nicole V. Ruiter, Kai Hohlfeld, Patrick Pfistner, Michael Zapf, Alexander Michaelis, Koen W. A. van Dongen, Hartmut Gemmeke, and Publica
- Subjects
ultrasound computer tomography ,ultrasonic transducer ,Materials science ,Single fiber ,piezoelectric fiber ,020206 networking & telecommunications ,02 engineering and technology ,021001 nanoscience & nanotechnology ,Condensed Matter Physics ,3 d ultrasound ,Transducer ,0202 electrical engineering, electronic engineering, information engineering ,Medical imaging ,Ultrasound imaging ,General Materials Science ,Ultrasonic Tomography ,Tomography ,piezocomposite ,0210 nano-technology ,Biomedical engineering - Abstract
Ultrasound Computer Tomography (USCT) medical imaging is a promising approach for early detection of breast cancer. At Karlsruhe Institute of Technology (KIT) a 3D USCT system is developed. The system operates 2041 ultrasound transducers in a semi-ellipsoidal aperture surrounding a region of interest (ROI) of 10 cm x 10 cm x 10 cm. Results from a first patient study reveal the requirement of a significantly increased ROI to cover bodily variations. Design considerations and simulations show a demand for circular transducers of approximately 500 mm diameter, increasing the opening angle of the transducers to approximately 60°. Piezofiber composite technology is predestinated to simply provide circular transducers of the required dimensions. Moreover, piezocomposites based on single PZT (lead zirconate titanate Pb[ZrxTi1-x]O3) fibers enable a cost-effective and series-production alternative to currently used dice-and-fill composites. A transducer design is presented which utilizes individually arranged single piezoceramic fibers with 460 µm in diameter within piezocomposite discs. As result fibers are independently addressable as single transducer elements allowing for the desired transducer arrangement. The electrical performance of each piezoceramic fiber is determined proofing a strong dependence of coupling coefficient and resonance frequency from transducer thickness. In further processing, the piezocomposite discs are connected to printed circuits, integrated into a cylindrical housing and backfilled with polyurethane. Ultrasound characteristics such as sound pressure and opening angle are evaluated quantitatively. The transducer opening angles are in the expected range, desired center frequency is achieved and bandwidth preserved compared to former dice-and-fill transducers.
- Published
- 2018
- Full Text
- View/download PDF
41. Automated Multimodal Computer Aided Detection Based on a 3D-2D Image Registration
- Author
-
Nicole V. Ruiter, Torsten Hopp, and B. Neupane
- Subjects
medicine.diagnostic_test ,Computer science ,business.industry ,Image registration ,Combined approach ,Computer aided detection ,030218 nuclear medicine & medical imaging ,03 medical and health sciences ,0302 clinical medicine ,030220 oncology & carcinogenesis ,medicine ,Mammography ,Computer vision ,Artificial intelligence ,Sensitivity (control systems) ,business ,X ray mammography - Abstract
Computer aided detection CADe of breast cancer is mainly focused on monomodal applications. We propose an automated multimodal CADe approach, which uses patient-specific image registration of MRI and X-ray mammography to estimate the spatial correspondence of tissue structures. Then, based on the spatial correspondence, features are extracted from both MRI and X-ray mammography. As proof of principle, distinct regions of interest ROI were classified into normal and suspect tissue. We investigated the performance of different classifiers, compare our combined approach against a classification with MRI features only and evaluate the influence of the registration error. Using the multimodal information, the sensitivity for detecting suspect ROIs improved by 7i¾?% compared to MRI-only detection. The registration error influences the results: using only datasets with a registration error below $$10\,mm$$, the sensitivity for the multimodal detection increases by 10i¾?% to a maximum of 88i¾?%, while the specificity remains constant. We conclude that automatically combining MRI and X-ray can enhance the result of a CADe system.
- Published
- 2016
- Full Text
- View/download PDF
42. Newton's method based self calibration for a 3D ultrasound tomography system
- Author
-
Nicole V. Ruiter, Wei Yap Tan, and Till Steiner
- Subjects
medicine.diagnostic_test ,Computer science ,Calibration (statistics) ,business.industry ,Ultrasound ,ComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISION ,Process (computing) ,symbols.namesake ,Transducer ,Feature (computer vision) ,Component (UML) ,symbols ,medicine ,Computer vision ,3D ultrasound ,Tomography ,Artificial intelligence ,business ,Newton's method - Abstract
A device for 3D ultrasound computer tomography system is currently under development at KIT with the goal of high-resolution images for early breast cancer detection. With its semi-ellipsoidal positioning of 2041 ultrasound transducers around the breast in space, full 3D images can be reconstructed. Calibration process of such a complex system is very time-consuming and difficult. This paper proposes a Newton's method based self calibration using time-of-flight measurements between each emitter and receiver. One unique feature of this method is the separation of each potential error sources in the system and sequential calibration according to their magnitudes. This enables the analysis of each error component in the system. Simulation and application on real data have both shown sub-wavelength accuracy in the calibration results.
- Published
- 2015
- Full Text
- View/download PDF
43. Evaluation of Huffman Sequences based mismatched filter for bandwidth limited 3D USCT system
- Author
-
Shreyank Gupta, Nicole V. Ruiter, Herbert Krauss, and Michael Zapf
- Subjects
Signal processing ,medicine.diagnostic_test ,business.industry ,Main lobe ,Computer science ,Acoustics ,Matched filter ,Bandwidth (signal processing) ,Huffman coding ,symbols.namesake ,Transducer ,Side lobe ,medicine ,symbols ,3D ultrasound ,Telecommunications ,business - Abstract
3D Ultrasound Computer Tomography (USCT) aims at early detection of breast cancer. The system was optimized for Synthetic Aperture Focusing Technique (SAFT) using unfocused ultrasound transducers. Due to low SNR of the signals, Coded Excitation (CE) and Matched Filter (MF) are applied. For complex objects the received signals (A-scans) consist of multiple overlaid reflections. The overlaid reflections are difficult to separate due to the system's limited bandwidth which results in side lobes. Non-separable reflections limit the resolution and contrast of the resulting images. Using Huffman Sequences (HS) as CE, a trade-off can be set between the side lobe suppression and loss of main lobe energy. Higher suppression of side lobes results in reduced energy in the CE, i.e. smaller SNR. So an approach has been implemented which suppresses the side lobes, but preserves the energy of CE by designing a Huffman sequences based mismatched filter. Combination of a CE and different filters were evaluated for single reflection and multiple overlaid reflections. The results show high side lobe suppression within limited bandwidth and preserve the SNR.
- Published
- 2015
- Full Text
- View/download PDF
44. Comparison of active-set method deconvolution and matched-filtering for derivation of an ultrasound transit time spectrum
- Author
-
Michael Zapf, Marie-Luise Wille, Christian M. Langton, Hartmut Gemmeke, and Nicole V. Ruiter
- Subjects
Time Factors ,Radiological and Ultrasound Technology ,business.industry ,Computer science ,Ultrasound ,Water ,Image processing ,Signal Processing, Computer-Assisted ,Filter (signal processing) ,Signal ,Standard deviation ,Chirp ,Radiology, Nuclear Medicine and imaging ,Detection theory ,Computer Simulation ,Ultrasonics ,Tomography ,Deconvolution ,business ,Telecommunications ,Algorithm ,Active set method - Abstract
The quality of ultrasound computed tomography imaging is primarily determined by the accuracy of ultrasound transit time measurement. A major problem in analysis is the overlap of signals making it difficult to detect the correct transit time. The current standard is to apply a matched-filtering approach to the input and output signals. This study compares the matched-filtering technique with active set deconvolution to derive a transit time spectrum from a coded excitation chirp signal and the measured output signal. The ultrasound wave travels in a direct and a reflected path to the receiver, resulting in an overlap in the recorded output signal. The matched-filtering and deconvolution techniques were applied to determine the transit times associated with the two signal paths. Both techniques were able to detect the two different transit times; while matched-filtering has a better accuracy (0.13 μs versus 0.18 μs standard deviations), deconvolution has a 3.5 times improved side-lobe to main-lobe ratio. A higher side-lobe suppression is important to further improve image fidelity. These results suggest that a future combination of both techniques would provide improved signal detection and hence improved image fidelity.
- Published
- 2015
45. Comparing different ultrasound imaging methods for breast cancer detection
- Author
-
Koen W. A. van Dongen, Michael Zapf, Hartmut Gemmeke, Nicole V. Ruiter, Robin Dapp, and Neslihan Ozmen
- Subjects
Diffraction ,integral equations ,Acoustics and Ultrasonics ,Computer science ,Physics::Medical Physics ,Breast Neoplasms ,Iterative reconstruction ,Sensitivity and Specificity ,Synthetic data ,Circular buffer ,Optics ,Image Interpretation, Computer-Assisted ,Humans ,Electrical and Electronic Engineering ,Instrumentation ,breast ,receivers ,business.industry ,Ultrasound ,scattering ,imaging ,Reproducibility of Results ,Inversion (meteorology) ,image reconstruction ,Image Enhancement ,frequency-domain analysis ,Frequency domain ,Female ,Tomography ,Ultrasonography, Mammary ,business ,Algorithms - Abstract
Ultrasound is frequently used to evaluate suspicious masses in breasts. These evaluations could be improved by taking advantage of advanced imaging algorithms, which become feasible for low frequencies if accurate knowledge about the phase and amplitude of the wave field illuminating the volume of interest is available. In this study, we compare five imaging and inversion methods: time-of-flight tomography, synthetic aperture focusing technique, backpropagation, Born inversion, and contrast source inversion. All methods are tested on the same full-wave synthetic data representing a 2-D scan using a circular array enclosing a cancerous breast submerged in water. Of the tested methods, only contrast source inversion yielded an accurate reconstruction of the speed-ofsound profile of the tumor and its surroundings, because only this method takes effects such as multiple scattering, refraction, and diffraction into account.
- Published
- 2015
46. Registration of 3D ultrasound computer tomography and MRI for evaluation of tissue correspondences
- Author
-
Michael Zapf, Nicole V. Ruiter, Torsten Hopp, Hartmut Gemmeke, Robin Dapp, and Ernst Kretzek
- Subjects
medicine.medical_specialty ,Image fusion ,Modality (human–computer interaction) ,medicine.diagnostic_test ,business.industry ,Breast imaging ,Computer science ,Image registration ,Magnetic resonance imaging ,medicine.disease ,Breast cancer ,medicine ,3D ultrasound ,Medical physics ,Ultrasonic Tomography ,Tomography ,Ultrasonography ,business ,Biomedical engineering - Abstract
3D Ultrasound Computer Tomography (USCT) is a new imaging method for breast cancer diagnosis. In the current state of development it is essential to correlate USCT with a known imaging modality like MRI to evaluate how different tissue types are depicted. Due to different imaging conditions, e.g. with the breast subject to buoyancy in USCT, a direct correlation is demanding. We present a 3D image registration method to reduce positioning differences and allow direct side-by-side comparison of USCT and MRI volumes. It is based on a two-step approach including a buoyancy simulation with a biomechanical model and free form deformations using cubic B-Splines for a surface refinement. Simulation parameters are optimized patient-specifically in a simulated annealing scheme. The method was evaluated with in-vivo datasets resulting in an average registration error below 5mm. Correlating tissue structures can thereby be located in the same or nearby slices in both modalities and three-dimensional non-linear deformations due to the buoyancy are reduced. Image fusion of MRI volumes and USCT sound speed volumes was performed for intuitive display. By applying the registration to data of our first in-vivo study with the KIT 3D USCT, we could correlate several tissue structures in MRI and USCT images and learn how connective tissue, carcinomas and breast implants observed in the MRI are depicted in the USCT imaging modes.
- Published
- 2015
- Full Text
- View/download PDF
47. GPU-based 3D SAFT reconstruction including attenuation correction
- Author
-
Nicole V. Ruiter, Torsten Hopp, and Ernst Kretzek
- Subjects
medicine.diagnostic_test ,Image quality ,business.industry ,Computer science ,Attenuation ,media_common.quotation_subject ,For Attenuation Correction ,Reflectivity ,Optics ,Approximation error ,medicine ,Contrast (vision) ,3D ultrasound ,Tomography ,business ,Correction for attenuation ,media_common - Abstract
3D Ultrasound Computer Tomography (3D USCT) promises reproducible high-resolution images for early detection of breast tumors. The KIT prototype provides three different modalities: reflectivity, speed of sound, and attenuation. The reflectivity images are reconstructed using a Synthetic Aperture Focusing Technique (SAFT) algorithm. For high-resolution re ectivity images, with spatially homogeneous reflectivity, attenuation correction is necessary. In this paper we present a GPU accelerated attenuation correction for 3D USCT and evaluate the method by means of image quality metrics; i.e. absolute error, contrast and spatially homogeneous reflectivity. A threshold for attenuation correction was introduced to preserve a high contrast. Simulated and in-vivo data were used for analysis of the image quality. Attenuation correction increases the image quality by improving spatially homogeneous reflectivity by 25 %. This leads to a factor 2.8 higher contrast for in-vivo data.
- Published
- 2015
- Full Text
- View/download PDF
48. Model-based registration of X-ray mammograms and MR images of the female breast
- Author
-
T.O. Muller, Hartmut Gemmeke, Nicole V. Ruiter, Jürgen R. Reichenbach, Werner A. Kaiser, and Rainer Stotzka
- Subjects
Nuclear and High Energy Physics ,medicine.medical_specialty ,medicine.diagnostic_test ,business.industry ,Image registration ,medicine.disease ,Finite element simulation ,Automatic localization ,Breast cancer ,Nuclear Energy and Engineering ,medicine ,Mammography ,Medical physics ,Electrical and Electronic Engineering ,Mr images ,skin and connective tissue diseases ,business ,Nuclear medicine - Abstract
We present a new approach for automatic registration of X-ray mammograms and MR images. Multimodal breast cancer diagnosis is supported by automatic localization of small lesions, which are only visible in the mammograms or in the MR image. To cope with the huge deformation of the breast during mammography, a finite element model of the deformable behavior of the breast is applied during the registration. An evaluation of the registration with six clinical data sets resulted in an accurate localization with a mean displacement of 4.3 mm (/spl plusmn/1 mm) and 3.9 mm (/spl plusmn/1.7 mm) for predicting the lesion position in mammograms and in the MR images, respectively.
- Published
- 2006
- Full Text
- View/download PDF
49. Registration of CT and MRI volume data of the liver
- Author
-
Thomas Böttger, Rainer Stotzka, Rolf Bendl, Nicole V. Ruiter, and Klaus Herfarth
- Subjects
Automatic control ,Computer science ,business.industry ,Computation ,Image registration ,General Medicine ,Mutual information ,Transformation (function) ,Computer vision ,Artificial intelligence ,Spline interpolation ,Radiation treatment planning ,business ,Rigid transformation - Abstract
The paper introduces a way to improve treatment planning of single-dose radiation therapy of liver tumors. Therefore, a new algorithm for the registration of diagnostic magnetic resonance images (MRI) and the computed tomography (CT) data used for treatment planning was developed. The described algorithm is divided into two stages. First, the two data sets are aligned by optimization of mutual information using rigid transformations. After this initial registration step, a nonrigid transformation based on thin-plate splines is performed, modeling the deformations of the soft tissue. An algorithm for automatic control point computation was developed, which is supposed to simplify the time-consuming task of defining the control points necessary for a thin-plate spline interpolation. The obtained results show that the implemented algorithm can successfully solve the registration problem.
- Published
- 2003
- Full Text
- View/download PDF
50. Co-registration of MR-mammography and X-ray mammography
- Author
-
Pascal A. T. Baltzer, Torsten Hopp, Werner A. Kaiser, Nicole V. Ruiter, and Matthias Dietzel
- Subjects
medicine.medical_specialty ,Co registration ,Breast Neoplasms ,Multimodal Imaging ,Sensitivity and Specificity ,Pattern Recognition, Automated ,Image Interpretation, Computer-Assisted ,medicine ,Humans ,Radiology, Nuclear Medicine and imaging ,Medical physics ,Neuroradiology ,medicine.diagnostic_test ,business.industry ,Reproducibility of Results ,Interventional radiology ,General Medicine ,Image Enhancement ,Magnetic Resonance Imaging ,Subtraction Technique ,Female ,business ,X ray mammography ,Algorithms ,Mammography ,Mr mammography - Abstract
aDepartment of Neuroradiology, University of Erlangen-Nurnberg, Schwabachanlage 6, D-91054, Germany bDepartment of Radiology, Division of Molecular and Gender Imaging, Medical University Vienna, Wahringer Gurtel 18–20, A-1090, Vienna, Austria c Karlsruhe Institute of Technology (KIT), Institute for Data Processing and Electronics, Postfach 3640, D-76021 Karlsruhe, Germany d Institute of Diagnostic and Interventional Radiology I, Friedrich-Schiller-University Jena, Erlanger Allee 101, D-07740 Jena, Germany
- Published
- 2012
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.