1. Randomized Comparison of J-Shaped Atrial Leads with and without Active Fixation Mechanism
- Author
-
Micha S. Feinberg, Osnat T. Gurevitz, Michael Eldar, David S. Bar-Lev, Michael Glikson, Nechemia Tanami, Chava Granit, and David Luria
- Subjects
Male ,Pacemaker, Artificial ,medicine.medical_specialty ,Risk Assessment ,Prosthesis Implantation ,Crossover rate ,Risk Factors ,Internal medicine ,Atrial Fibrillation ,Prevalence ,medicine ,Humans ,Lead Dislodgement ,In patient ,Implantation procedure ,Israel ,Lead (electronics) ,Aged ,Fixation (histology) ,business.industry ,Cardiac Pacing, Artificial ,General Medicine ,Prognosis ,Electrodes, Implanted ,Surgery ,Treatment Outcome ,Effusion ,Cardiology ,Female ,Cardiology and Cardiovascular Medicine ,business ,Active fixation - Abstract
Background: In this prospective, randomized, controlled study, we compared the performance of J-shaped active fixation (AF) atrial leads with J-shaped passive fixation (PF) leads, over a 1-year follow-up period. Methods: A total of 200 consecutive patients were prospectively randomized for implantation with a Medtronic 5568 AF lead model (n = 103; Minneapolis, MN, USA) versus a Medtronic 5592 PF model (n = 97), and all lead-related measurements and complications were recorded over one year. Results: All leads were successfully implanted with a nonsignificant difference in crossover rate to the alternative lead due to failed implantation (1 in the AF and 4 in the PF group, P = NS). Fluoroscopy time during implantation procedure was significantly shorter in the PF group (2.1 ± 3.6 vs 3.3 ± 4.5 minute, P < 0.05). Pacing thresholds during implantation were significantly lower in patients with PF leads (0.7 ± 0.3 V vs 0.9 ± 0.3 V, P < 0.001) and this difference persisted at 1-year follow-up (0.8 ± 0.6 V vs 1.3 ± 0.9 V in PF and AF leads respectively, P < 0.05). Lead-related complications occurred in PF and AF with similar frequency (4% and 9% respectively, P = 0.2). However, pericardial complications occurred only in the AF group (6 cases, P = 0.01). Lead dislodgement was observed in only two cases—both in the PF group (P = 0.3). Conclusion: Both types of J-shaped atrial leads had reasonable performance. PF leads required shorter fluoroscopy time for implantation, demonstrated a better pacing threshold over a 1-year follow-up period and had no pericardial complications, while AF lead implantation was complicated by pericardial irritation and/or effusion in 6% cases (P = 0.01).
- Published
- 2007