12 results on '"Huaquan Fan"'
Search Results
2. Highly Porous 3D Printed Tantalum Scaffolds Have Better Biomechanical and Microstructural Properties than Titanium Scaffolds
- Author
-
Guohua Wang, Fuyou Wang, Caihua Tan, Huaquan Fan, Jianzhong Tang, Tang Wentao, Aikeremujiang Muheremu, Liu Yang, Shu Deng, Xianzhe Wu, He Peng, and Kaixuan Guo
- Subjects
3d printed ,Scaffold ,Materials science ,Article Subject ,Swine ,Tantalum ,Modulus ,chemistry.chemical_element ,General Biochemistry, Genetics and Molecular Biology ,law.invention ,law ,Highly porous ,Animals ,Selective laser melting ,Composite material ,Titanium ,Tissue Scaffolds ,General Immunology and Microbiology ,technology, industry, and agriculture ,General Medicine ,Biomechanical Phenomena ,chemistry ,Printing, Three-Dimensional ,Medicine ,Stress, Mechanical ,Electron microscope ,Porosity ,Research Article - Abstract
Objective. To test the biomechanical properties of 3D printed tantalum and titanium porous scaffolds. Methods. Four types of tantalum and titanium scaffolds with four alternative pore diameters, #1 (1000-700 μm), #2 (700-1000 μm), #3 (500-800 μm), and #4 (800-500 μm), were molded by selective laser melting technique, and the scaffolds were tested by scanning electronic microscope, uniaxial-compression tests, and Young’s modulus tests; they were compared with same size pig femoral bone scaffolds. Results. Under uniaxial-compression tests, equivalent stress of tantalum scaffold was 411 ± 1.43 MPa, which was significantly larger than the titanium scaffolds ( P < 0.05 ). Young’s modulus of tantalum scaffold was 2.61 ± 0.02 GPa, which was only half of that of titanium scaffold. The stress-strain curves of tantalum scaffolds were more similar to pig bone scaffolds than titanium scaffolds. Conclusion. 3D printed tantalum scaffolds with varying pore diameters are more similar to actual bone scaffolds compared with titanium scaffolds in biomechanical properties.
- Published
- 2021
- Full Text
- View/download PDF
3. Gait Analysis after Total Knee Arthroplasty Assisted by 3D-Printed Personalized Guide
- Author
-
Ying Zhang, Rui He, De‐jie Fu, Yang Peng, Huaquan Fan, and Maolin Sun
- Subjects
Male ,musculoskeletal diseases ,3d printed ,Article Subject ,Knee Joint ,Total knee arthroplasty ,General Biochemistry, Genetics and Molecular Biology ,03 medical and health sciences ,0302 clinical medicine ,Gait (human) ,Humans ,Medicine ,030212 general & internal medicine ,Arthroplasty, Replacement, Knee ,Rotational alignment ,Aged ,Retrospective Studies ,Orthodontics ,030222 orthopedics ,General Immunology and Microbiology ,Flexion angle ,business.industry ,Significant difference ,General Medicine ,Middle Aged ,Osteoarthritis, Knee ,musculoskeletal system ,Gait analysis ,Clinical Study ,Female ,Patella ,Gait Analysis ,Knee Prosthesis ,business ,human activities ,Follow-Up Studies - Abstract
Background. With the development of three-dimensional printing (3DP) technology, the patient-specific instrumentation (PSI) has been widely applied in total knee arthroplasty (TKA). The purpose of this study was to compare the gait parameters of patients with 3DP personalized guide-assisted and standard TKA. Methods. Retrospective analysis of the advanced knee OA cases in our hospital between June 2017 and June 2018 was conducted. 30 cases received 3DP personalized guide-assisted TKA (group A), and 60 patients who underwent standard TKA during the same period were in group B and group C according to the computed tomography (CT) measurement results, each with 30 cases. Hip–knee–ankle angle (HKA), patella transverse axis-femoral transepicondylar axis angle (PFA), and gait parameters were statistically analyzed. The function was assessed by Hospital for Specific Surgery (HSS) and Knee Society Score (KSS). Results. The mean follow-up period was 12.3 months in the three groups. The knee max flexion angle at the swing phase of group A was larger than group B and group C (P<0.05), there was no statistically significant difference in other gait parameters. The mean PFA of group A was smaller than that of group B and group C (P<0.05). While, the HKA, HSS, and KSS scores of three groups showed no significant difference. Conclusion. 3DP personalized guide technology could improve the gait parameters after surgery, specifically reflected in the knee max flexion angle at the swing phase. It could also assist in the reconstruction of more accurate patellar tracking and rotational alignment in TKA, avoiding the occurrence of insufficient or excessive extorsion.
- Published
- 2020
- Full Text
- View/download PDF
4. Outcomes after Total Hip Arthroplasty Using a Cementless S‐ROM Modular Stem for Patients with High Hip Dislocation Secondary to Hip Pyogenic Arthritis
- Author
-
Li Ning, Huaquan Fan, Yu Zhou, Min Zhou, Shao-lin Wang, Yi Zhou, Ming-quan Zhou, Yang Yang, Qiu‐Ping Yu, Zhang Shengli, Juan Li, Liu Junli, and Zhang Xin
- Subjects
Adult ,Male ,musculoskeletal diseases ,medicine.medical_specialty ,WOMAC ,Limp ,Arthroplasty, Replacement, Hip ,Radiography ,Arthritis ,Pyogenic arthritis ,03 medical and health sciences ,0302 clinical medicine ,lcsh:Orthopedic surgery ,Paralysis ,medicine ,Hip Dislocation ,Humans ,Orthopedics and Sports Medicine ,Retrospective Studies ,Arthritis, Infectious ,030222 orthopedics ,Clinical Article ,S‐ROM stem ,business.industry ,Incidence (epidemiology) ,High dislocation ,Middle Aged ,medicine.disease ,Low back pain ,Osteotomy ,Surgery ,lcsh:RD701-811 ,Treatment Outcome ,Harris Hip Score ,Clinical Articles ,Subtrochanteric shortening osteotomy ,Female ,Total hip arthroplasty ,Hip Prosthesis ,medicine.symptom ,business ,030217 neurology & neurosurgery ,Follow-Up Studies - Abstract
Objective To evaluate the midterm results of the cementless S-ROM modular femoral stem used with subtrochanteric transverse shortening osteotomy for the treatment of high hip dislocation secondary to hip pyogenic arthritis. Methods We retrospectively reviewed the data of 49 patients (49 hips) with an average infection quiescent period of 37.4 years who underwent cementless total hip arthroplasty (THA) with simultaneous subtrochanteric transverse shortening osteotomy from July 2008 to June 2012. There were 23 men and 26 women with a mean age of 44.3 years at the time of surgery. The following clinical outcomes were evaluated: the Western Ontario and McMaster Universities Arthritis Index (WOMAC) score, Harris hip score (HSS), modified Merle d'Aubigne-Postel hip (MAP) score, low back pain visual analog scale score, 12-item short-form health survey questionnaire score, limp, and Trendelenburg sign. Radiographic outcomes and complications were also evaluated. Results The mean follow-up period was 8.7 years (range, 5.5-10 years). No infection recurrence was observed after THA. The average HSS significantly improved from 45.0 to 84.8. The WOMAC score improved from 70.1 ± 3.5 (range, 65-76) to 43.1 ± 13.4 (range, 21-67). The modified MAP score improved from 5.9 ± 1.9 (range, 3-9) to 14.3 ± 2.4 (range, 11-18). The low back pain visual analog scale score, 12-item short-form health survey questionnaire score, limp, and Trendelenburg sign also improved significantly. The average limb length discrepancy decreased from 39.6 mm (range, 30-55 mm) to 7.2 mm (range, 0-22 mm). Two patients had temporary sciatic nerve paralysis but recovered within 6 months without any functional defects; one had an intraoperative fracture fixed by cerclage wires. One hip required revision surgery because of femoral stem aseptic loosening. Conclusions The cementless S-ROM modular femoral stem used with subtrochanteric transverse shortening osteotomy is safe and effective for high hip dislocation secondary to pyogenic arthritis and provides satisfactory midterm results. Significant improvements in clinical function were observed, as were high rates of stable fixation of the cementless implant, restoration of more normal limb lengths, and a low incidence of complications.
- Published
- 2019
- Full Text
- View/download PDF
5. Application of 3D‐printed Customized Guides in Subtalar Joint Arthrodesis
- Author
-
He Peng, Fuyou Wang, Xiaojun Duan, Huaquan Fan, and Liu Yang
- Subjects
Adult ,Male ,Models, Anatomic ,musculoskeletal diseases ,3d printed ,Arthrodesis ,medicine.medical_treatment ,Intraoperative radiation ,03 medical and health sciences ,0302 clinical medicine ,lcsh:Orthopedic surgery ,Subtalar fusion ,Subtalar joint ,Preoperative Care ,medicine ,Humans ,Orthopedics and Sports Medicine ,Kirschner wire ,Aged ,Retrospective Studies ,Postoperative Care ,Orthodontics ,030222 orthopedics ,Clinical Article ,Drill ,business.industry ,Arthritis ,Subtalar Joint ,3D printing ,Middle Aged ,lcsh:RD701-811 ,Treatment Outcome ,medicine.anatomical_structure ,Printing, Three-Dimensional ,Clinical Articles ,Customized guide ,Feasibility Studies ,Female ,Surgery ,Ankle ,Tomography, X-Ray Computed ,business ,030217 neurology & neurosurgery ,Bone Wires ,Follow-Up Studies - Abstract
Objective To explore the feasibility of 3D printed customized guides assisting the precise drilling of Kirschner wires in subtalar joint arthrodesis. Methods We retrospectively reviewed the data of 29 patients (30 subtalar joints) who underwent subtalar joint arthrodesis between 1 July 2013 and 31 December 2017. The customized guides were designed on a full‐scale 3D polylactic acid model made from computed tomography (CT) data of patients by Model Intestinal Microflora in Computer Simulation (MIMICS) software, which were manufactured by 3D printing technology. A total of 14 joints used customized guides (experimental group); the remained 16 joints used the traditional method (control group). The time of drilling the Kirschner wires to the correct position, the time of subtalar fusion, American Orthopaedic Foot & Ankle Society (AOFAS) scores, and complications were evaluated in both groups. Results All customized guides were successfully manufactured. In the experimental group, it took 2.1 ± 0.7 min to drill the Kirschner wire to the satisfactory position, and 2 cases needed to be re‐drilled; in the control group, it took 4.6 ± 1.9 min to drill the Kirschner wire to the satisfactory position (P 0.05). Conclusion It is safe to apply 3D‐printed customized guides for subtalar joint arthrodesis, which can assist the accurate drilling of Kirschner wires into the appropriate position according to the preoperative plan, and reduce the operation time as well as intraoperative radiation.
- Published
- 2019
- Full Text
- View/download PDF
6. Scaffold With Natural Calcified Cartilage Zone for Osteochondral Defect Repair in Minipigs
- Author
-
Fuyou Wang, Liu Yang, Yang Huang, Huaquan Fan, and Xiaoyuan Gong
- Subjects
Cartilage, Articular ,Defect repair ,Scaffold ,2019-20 coronavirus outbreak ,Coronavirus disease 2019 (COVID-19) ,Swine ,Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) ,Physical Therapy, Sports Therapy and Rehabilitation ,Osteochondral scaffold ,Calcified cartilage ,03 medical and health sciences ,0302 clinical medicine ,Medicine ,Animals ,Orthopedics and Sports Medicine ,030222 orthopedics ,Tissue Engineering ,Tissue Scaffolds ,business.industry ,Cartilage ,030229 sport sciences ,medicine.anatomical_structure ,Hyaline Cartilage ,Swine, Miniature ,business ,Biomedical engineering - Abstract
Background:Long-term outcomes of current clinical interventions for osteochondral defect are less than satisfactory. One possible reason is an ignorance of the interface structure between cartilage and subchondral bone, the calcified cartilage zone (CCZ). However, the importance of natural CCZ in osteochondral defects has not been directly described.Purpose:To explore the feasibility of fabricating trilayer scaffold containing natural CCZ for osteochondral defects and the role of CCZ in the repair process.Study Design:Controlled laboratory study.Methods:The scaffold was prepared by cross-linking lyophilized type II collagen sponge and acellular normal pig subchondral bone with or without natural CCZ. Autologous bone marrow stem cells (BMSCs) of minipig were mixed with type II collagen gel and injected into the cartilage layer of the scaffold before operation. Thirty minipigs were randomly divided into CCZ (n = 10), non-CCZ (n = 10), and blank control (n = 10) groups. An 8 mm–diameter full-thickness osteochondral defect was created on the trochlear surface, and scaffold containing BMSCs was transplanted into the defect according to grouping requirements. At 12 and 24 weeks postoperatively, specimens were assessed by macroscopic observation, magnetic resonance imaging examination, and histological observations (hematoxylin and eosin, Safranin O–fast green, type II collagen immunohistochemical, and Sirius red staining). Semiquantitative cartilage repair scoring was conducted using the MOCART (Magnetic Resonance Observation of Cartilage Repair Tissue) system and the O’Driscoll repaired cartilage value system.Results:The defects in the blank control and non-CCZ groups were filled with fibrous tissue, while the cartilage layer of the CCZ group was mainly repaired by hyaline cartilage at 24 weeks postoperatively. The superior repair outcome of the CCZ group was confirmed by MOCART and O’Driscoll score.Conclusion:The trilayer scaffold containing natural CCZ obtained the best repair effect compared with the non-CCZ scaffold and the blank control, indicating the importance of the CCZ in osteochondral tissue engineering.Clinical Relevance:This study demonstrates the necessity to reconstruct CCZ in clinical osteochondral defect repair and provides a possible strategy for osteochondral tissue engineering.
- Published
- 2021
7. Is Valgus Cut Angle Based on Radiographic Measurements in Total Knee Arthroplasty Really Inaccurate? A Comparison of Two- and Three-Dimensional Measurements
- Author
-
Kai Lei, Lin Guo, Xin Chen, Liu Yang, Huaquan Fan, and LiMing Liu
- Subjects
musculoskeletal diseases ,Orthodontics ,Anatomical axis ,030222 orthopedics ,biology ,business.industry ,Radiography ,Total knee arthroplasty ,Statistical difference ,3d model ,030229 sport sciences ,musculoskeletal system ,biology.organism_classification ,stomatognathic diseases ,03 medical and health sciences ,Valgus ,0302 clinical medicine ,Coronal plane ,otorhinolaryngologic diseases ,Medicine ,Orthopedics and Sports Medicine ,Surgery ,Lateral femoral bowing ,business - Abstract
Radiographs are widely used to measure distal femoral valgus cut angle (VCA) in total knee arthroplasty (TKA), but its accuracy is controversial. This study used three-dimensional (3D) reconstruction models to verify the accuracy of VCA measurements on radiographs, and explore the correlation of VCA with hip–knee–ankle (HKA) angle and lateral femoral bowing angle (FBA). A total of 444 osteoarthritis knees of 444 patients from August 2016 to June 2018 was included retrospectively. On radiographs, two-dimensional VCA (VCA-2D) was measured between the femoral mechanical axis and the distal femoral anatomical axis, and HKA was measured between the femoral mechanical axis and the tibial mechanical axis. On the coronal projection of computed tomography 3D models, the anatomical landmarks used for VCA-3D measurements were the same as those on the radiographs, FBA was measured between the proximal and distal femoral anatomical axis. The distributions of VCA-2D and VCA-3D were evaluated by means and variances. The correlation between HKA and VCA and between FBA and VCA was explored. There was a statistical difference between VCA-2D and VCA-3D (p
- Published
- 2021
8. Three-dimensional printed implant for reconstruction of pelvic bone after removal of giant chondrosarcoma: a case report
- Author
-
Huaquan Fan, Chang Chen, Aikeremujiang Muheremu, Ge Chen, Xianzhe Wu, Liu Yang, Juncai Liu, Fuyou Wang, Zhong Li, and He Peng
- Subjects
musculoskeletal diseases ,Adult ,medicine.medical_specialty ,Medicine (General) ,animal structures ,implant ,Bone Neoplasms ,Case Reports ,030204 cardiovascular system & hematology ,Prosthesis Design ,Biochemistry ,Pelvis ,03 medical and health sciences ,0302 clinical medicine ,R5-920 ,Imaging, Three-Dimensional ,Medicine ,Humans ,case report ,titanium ,three-dimensional printing ,Pelvic Bones ,chondrosarcoma ,Bone-Anchored Prosthesis ,business.industry ,Biochemistry (medical) ,Cell Biology ,General Medicine ,Plastic Surgery Procedures ,musculoskeletal system ,medicine.disease ,Tumor Burden ,medicine.anatomical_structure ,Treatment Outcome ,030220 oncology & carcinogenesis ,Three dimensional printing ,embryonic structures ,Printing, Three-Dimensional ,Female ,Implant ,Radiology ,Chondrosarcoma ,business ,Tomography, X-Ray Computed - Abstract
Background Three-dimensional (3D) reconstruction has been used for various diseases, but few reports have described its application in pelvic reconstruction after removal of giant chondrosarcoma. Case reports describing the clinical application of personalized 3D-printed titanium implants are needed for future clinical reference. Case presentation: We herein describe a 29-year-old woman with a giant chondrosarcoma treated with a personalized 3D titanium implant. The surgery was successful, and the patient recovered with significant pain relief and good functional recovery after the surgery. No implant-related complications occurred during the 12-month follow-up. The current case represents successful application of 3D printing technology to the treatment of a massive bone defect due to the removal of a giant osteoporotic tumor. Conclusions Personalized 3D titanium implants can be used in the reconstruction of massive bone defects after the removal of giant pelvic sarcomas. The methodology and results described in the current case report can be a used as reference in the treatment of similar cases in future.
- Published
- 2020
9. Accuracy of a Novel 3D-Printed Patient-Specific Intramedullary Guide to Control Femoral Component Rotation in Total Knee Arthroplasty
- Author
-
Huaquan Fan, Rui He, De‐jie Fu, Maolin Sun, Ying Zhang, and Yang Peng
- Subjects
musculoskeletal diseases ,Male ,Patient-Specific Modeling ,medicine.medical_specialty ,Rotation ,Intramedullary guide ,medicine.medical_treatment ,Osteoarthritis ,Prosthesis Design ,Condyle ,law.invention ,Surgical transepicondylar axis ,Intramedullary rod ,03 medical and health sciences ,0302 clinical medicine ,lcsh:Orthopedic surgery ,law ,Prosthesis Fitting ,medicine ,Humans ,Orthopedics and Sports Medicine ,Femur ,Prospective Studies ,Arthroplasty, Replacement, Knee ,Aged ,Aged, 80 and over ,030222 orthopedics ,Clinical Article ,business.industry ,Rotational alignment ,Patient‐specific instrumentation ,Middle Aged ,medicine.disease ,musculoskeletal system ,Arthroplasty ,Surgery ,3D Printing ,lcsh:RD701-811 ,Total knee arthroplasty ,Printing, Three-Dimensional ,Clinical Articles ,Patella ,Female ,Range of motion ,business ,Rotation (mathematics) ,030217 neurology & neurosurgery - Abstract
OBJECTIVE Total knee arthroplasty (TKA) is one of the most universal and effective means for treating terminal stage osteoarthritis (OA) of knee. Accurate intramedullary guide of femur is the basis for the distal femoral cuts. Determining the surgical transepicondylar axis (sTEA) is the key to reconstruction of the femoral rotational alignment, because the correct rotational alignment can place the femoral component in the right position, balance the flexion gap so that the inner and outer tension is equal, get stability during the flexion process of the knee, and enhance the quality of life of patients. With the development of three-dimensional printing (3DP) technology in the medical domain, the application of patient-specific instrumentation (PSI) in arthroplasty has become more common. The aim of this study was to evaluate the accuracy of a novel 3D-printed patient-specific intramedullary guide to control femoral component rotation in TKA. METHODS Eighty patients (65 females and 15 males) with knee OA were included in this prospective randomized study. The patients were divided into two groups by random number table method, 40 in each group. TKA assisted by PSI (PSI group) and conventional TKA (conventional group) was performed respectively. Clinical outcomes [operation time, postoperative drainage volume, duration of drainage, Hospital for Special Surgery knee score (HSS), American Knee Society knee score (AKS)] and radiological outcomes [hip-knee-ankle angle (HKA), posterior condylar angle (PCA), patella transverse axis-femoral transepicondylar axis angle (PFA), depth of intramedullary guide] were compared between and within the two groups. RESULTS PSI group had less postoperative drainage volume but longer operation time than the conventional group (P < 0.05). The AKS and HSS scores after surgery were improved compared with those before surgery in each group (P < 0.05). However, there was no significant difference in the duration of drainage and range of motion (ROM) after surgery between the two groups. For the radiological results, the HKA and PFA were improved after surgery in both groups (P < 0.05).The postoperative PFA and PCA of the PSI group were closer to 0°, which was better than that of the conventional group (P < 0.05). The depth of intramedullary guide in the PSI group was less than the conventional group (P < 0.05). But there was no significant difference in HKA before and after surgery between the two groups as well as the preoperative PFA. CONCLUSION The short-term clinical efficacy of TKA assisted by PSI was similar to the conventional TKA. Although TKA assisted by PSI spent more time during operation, it could assist in intramedullary guide and align femoral rotation more accurately.
- Published
- 2019
10. The association between anterior femoroacetabular impingement and femoral neck fractures
- Author
-
Senlin Xu, Pengfei Yang, Huaquan Fan, Guangxing Chen, Liu Yang, and Xin Wang
- Subjects
Male ,Greater trochanter ,cam ,acetabular anteversion ,Observational Study ,Femoral Neck Fractures ,03 medical and health sciences ,Femoral head ,0302 clinical medicine ,Risk Factors ,falls ,Femoracetabular Impingement ,hip impingement ,medicine ,Humans ,030212 general & internal medicine ,Femoroacetabular impingement ,Aged ,Femoral neck ,Aged, 80 and over ,Labrum ,medicine.diagnostic_test ,business.industry ,Magnetic resonance imaging ,General Medicine ,Anatomy ,Middle Aged ,medicine.disease ,Magnetic Resonance Imaging ,Acetabulum ,medicine.anatomical_structure ,hip fracture ,030220 oncology & carcinogenesis ,Hip Joint ,business ,Research Article ,acetabulum labrum - Abstract
The impact between acetabulum and femoral neck is another possible mechanism of femoral neck fracture. Direct trauma of the greater trochanter may not be able to fully explain the mechanism underlying femoral neck fracture. In this study, we sought to investigate whether anterior femoroacetabular impingement are associated with femoral neck fractures. A total of 36 patients with femoral neck fracture who had undergone total hip arthroplasty or hemiarthroplasty were included in this study. These patients were divided into 2 groups: labrum tear group and normal labrum group. Patients’ age, gender, body mass index, muscle injury, injury pattern, trauma severity, femoral head-neck offset, femoral head-neck ratio, Cam deformity alpha angle, acetabular anteversion, femoral head diameter, acetabular index, cortical index, hip axis length, and neck stem angle were recorded and analyzed. SPSS 18.0 software was used for statistical analyses. According to intraoperative findings, 22 patients exhibited a labrum tear. Magnetic resonance imaging examination revealed bone contusion on the anterolateral margin of the acetabulum with muscle damage surrounding the hip. Among 14 cases without a labrum tear, no bone contusion and obvious muscle injury were found on the anterolateral margin of the acetabulum. Notably, muscle injury, injury pattern, trauma severity and femoral head-neck offset differed significantly (P
- Published
- 2020
- Full Text
- View/download PDF
11. Total hip arthroplasty for patients with Crowe type IV developmental dysplasia of the hip: Ten years results
- Author
-
Qiang Zhou, Xiaojun Duan, Liu Yang, Huaquan Fan, Guang-xing Chen, Fuyou Wang, Lin Guo, W.N. Zeng, Liu Junli, and Zhang Xin
- Subjects
musculoskeletal diseases ,Adult ,Male ,medicine.medical_specialty ,Osteolysis ,Adolescent ,Radiography ,medicine.medical_treatment ,Arthroplasty, Replacement, Hip ,Dentistry ,Osteotomy ,03 medical and health sciences ,Young Adult ,0302 clinical medicine ,Postoperative Complications ,Paralysis ,medicine ,Hip Dislocation ,Humans ,Femur ,030212 general & internal medicine ,Hip Dislocation, Congenital ,030222 orthopedics ,business.industry ,General Medicine ,Middle Aged ,medicine.disease ,Surgery ,Harris Hip Score ,Female ,Sciatic nerve ,medicine.symptom ,business ,Total hip arthroplasty ,Follow-Up Studies - Abstract
Background and objectives The aim of this study was to determine the rate of union, functional results and complications in patients with Crowe IV developmental dysplasia of the hip (DDH) who underwent cementless total hip arthroplasty (THA) with S-ROM prostheses and subtrochanteric transverse shortening osteotomy. Methods Forty-five patients (52 hips) operated between January 2005 and May 2008, with a mean age of 40.6 years at surgery were followed. The mean follow-up period was 9.8 years. Clinical outcomes, radiographic outcomes and complications were evaluated. Results Osteotomy union occurred in 52 of 52 femurs (100%). Mean Harris hip score improved from 33.7 ± 4.7 preoperatively to 81.2 ± 6.3, 90.8 ± 5.3 and 89.8 ± 7.1 at 1, 5 and 10 years postoperatively. Two patients had temporary sciatic nerve paralysis postoperatively, and 2 patients experienced early postoperative dislocation. Two patients complained about mild longer limb length than the non-operated limb at the last follow-up. Three hips showed osteolysis in Gruen zone 1, and 1 hip showed osteolysis in zone 1 and 7. No implants were revised, and no signs of component loosening and migration were observed at the last follow-up visit. Conclusions S-ROM stem combined with transverse subtrochanteric shortening osteotomy in THA for patients with Crowe type IV DDH has good clinical results with small risk of complications.
- Published
- 2016
12. Effects of niacin on nitric oxide synthase expression in rat lungs exposed to silica
- Author
-
Huaquan Fan, Chang'en Wang, Shao-xi Cai, Hai-ke Du, Xizhen Zhang, and Shi-xin Wang
- Subjects
Lung ,biology ,medicine.diagnostic_test ,Chemistry ,respiratory system ,medicine.disease ,High-performance liquid chromatography ,Molecular biology ,Nitric oxide synthase ,medicine.anatomical_structure ,Bronchoalveolar lavage ,Biochemistry ,Silicosis ,biology.protein ,medicine ,General Materials Science ,Quantitative analysis (chemistry) ,Niacin ,Peroxidase - Abstract
The aim of this study was to evaluate the effects of niacin in diet on the expression of nitric oxide synthase (NOS) in rat lungs of the animal model of silicosis established by direct tracheal instillation of silica particles into rat lungs surgically. The niacin concentration in serum was analyzed by high performance liquid chromatography (HPLC). The expression of inducible nitric oxide synthase (iNOS) protein in paraffin-embedded lung sections was determined by streptavidin/peroxidase (SP) staining. Quantitative analysis by Image-Pro Plus was also performed on the expression of iNOS. The results showed that niacin concentration in serum of the niacin-treated rats was significantly higher than that in the control and silica-treated rats. After 7 days of silica instillation, iNOS integrated optical density (IOD) in rat lungs and total NOS and iNOS activities in bronchoalveolar lavage fluid (BALF) in silica-treated rats rose by 273420. 75, 2.61 units/mL and 1.89 units/mL respectively, when compar...
- Published
- 2004
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.