1. A multi institutional comparison of imaging dose and technique protocols for neonatal chest radiography
- Author
-
Luís Lança, Catherine Gunn, Cláudia Teles Martins, Kristian Fosså, Mohamed Abdolell, H. Friedrich-Nel, H. Muller, Safora Johansen, K. O'Brien, and E. Tonkopi
- Subjects
Chest x-ray ,Canada ,Radiography ,Population ,Radiation Dosage ,030218 nuclear medicine & medical imaging ,Hospitals, University ,South Africa ,03 medical and health sciences ,0302 clinical medicine ,Exposure parameters ,Humans ,Medicine ,Radiology, Nuclear Medicine and imaging ,In patient ,education ,Lateral projection ,Protocol (science) ,education.field_of_study ,Portugal ,Norway ,business.industry ,Radiation dose ,Infant, Newborn ,Imaging dose ,Dose area product ,030220 oncology & carcinogenesis ,Paediatric imaging ,Radiography, Thoracic ,Radiology ,business ,Nuclear medicine ,Infant, Premature - Abstract
Introduction The focus on paediatric radiation dose reduction supports reevaluation of paediatric imaging protocols. This is particularly important in the neonates where chest radiographs are frequently requested to assess respiratory illness and line placement. This study aims to assess the impact of neonatal chest radiographic protocols on patient dose in four hospitals in different countries. Methods Exposure parameters, collimation, focus to skin distance (FSD) and radiation dose from 200 neonatal chest radiographs were registered prospectively. Inclusion criteria consisted of both premature and full-term neonates weighing between 1000 and 5000 g. Only data from the examinations meeting diagnostic criteria and approved for the clinical use were included. Radiation dose was assessed using dose area product (DAP). Results The lowest DAP value (4.58 mGy cm2) was recorded in the Norwegian hospital, employing a high kVp, low mAs protocol using a DR system. The Canadian hospital recorded the highest DAP (9.48), using lower kVp and higher mAs with a CR system, including the addition of a lateral projection. The difference in the mean DAP, weight, field of view (FOV) and kVp between the hospitals is statistically significant (p Conclusion Use of non-standardised imaging protocols in neonatal chest radiography results in differences in patient dose across hospitals included in the study. Using higher kVp, lower mAs and reducing the number of lateral projections to clinically relevant indications result in a lower DAP measured in the infant sample studied. Further studies to examine image quality based on exposure factors and added filtration are recommended. Implications for practice Reevaluation of paediatric imaging protocols presents an opportunity to reduce patient dose in a population with increased sensitivity to ionising radiation.
- Published
- 2020
- Full Text
- View/download PDF