27 results on '"Degree Of Conversion"'
Search Results
2. Influência do aparelho fotoativador sobre o grau de conversão de resinas bulk-fill.
- Author
-
Jochims SCHNEIDER, Luis Felipe, Carolina CARMELLO, Ana, Eiras PEREIRA, Leonardo Duarte, Pereira COUTO NETO, Mário, Antonio MODENA, Rodrigo, and Maria CAVALCANTE, Larissa
- Abstract
Copyright of Journal of Clinical Dentistry & Research is the property of Dental Press International and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2019
- Full Text
- View/download PDF
3. RESINAS COMPOSTAS NOS ÚLTIMOS 10 ANOS - REVISÃO DA LITERATURA. PARTE 3: FOTOATIVAÇÃO E GRAU DE CONVERSÃO.
- Author
-
Vinícius Soares, Paulo, Dias Silva, Amanda Monise, Ribeiro Wobido, Amanda, Rodrigues Reis, Bruno, and Oliveiros Cardoso, Igor
- Abstract
Copyright of Journal of Clinical Dentistry & Research is the property of Dental Press International and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2019
- Full Text
- View/download PDF
4. Influência da translucidez da zircónia no grau de conversão dos cimentos de resina. Uma revisão integrativa
- Author
-
Solis, Angela Lucia Prado and TORRES, ORLANDA DE ARAÚJO LAMAS CORREIA
- Subjects
Degree of conversion ,Transmittance ,Zirconia ,Resin cement ,Translucency ,Polymerization - Abstract
A zircónia é atualmente uma boa escolha para reabilitações dentárias, totais ou parciais, devido às suas importantes vantagens, tais como excelentes propriedades mecânicas, melhor estética, boas propriedades químicas, radiopacidade e baixo potencial de corrosão. O objetivo deste estudo é realizar uma revisão integrativa sobre a influência da translucidez da zircónia no grau de conversão dos cimentos de resina em artigos nos últimos 5 anos. A pesquisa bibliográfica foi realizada na base de dados PubMed. Foram recolhidos 10 artigos. Na plataforma ScienceDirect, foram encontrados 9 artigos. Após os critérios de inclusão foram seleccionados 5 artigos. Foram excluídos artigos não relacionados diretamente com o tema abordado. Na pesquisa manual foram escolhidos 5 artigos para complementar a revisão. Independentemente do tipo de cimento de resina utilizado, os grupos fotopolimerizados através da zircónia apresentavam valores de grau de conversão de monómeros mais elevados comparativamente com grupos polimerizados apenas através do processo de autopolimerização. Os cimentos de resina contendo maior Trietilenoglicol dimetacrilato exibiam o grau de conversão superior. Para espessuras ≥2mm, foram observadas reduções significativas no grau de conversão. A translucidez da zircónia é uma variável que determina o grau de conversão dos cimentos à base resina. Outros fatores que podem influenciar o grau de conversão, tais como a tonalidade, espessura do material cerâmico e composição. O grau de conversão afeta todo o processo de cimentação, portanto, um baixo grau de conversão afeta negativamente a adesão do material cerâmico e, por conseguinte, as suas propriedades físicas e mecânicas.
- Published
- 2022
5. Análise de propriedades químicas e mecânicas de diferentes resinas compostas quando mantidas em temperatura de refrigerador e ambiente
- Author
-
Aguiar, Larisse Martins, Carlo, Hugo Lemes, Santos Filho, Paulo César de Freitas, Carlo, Fabíola Galbiatti de carvalho, and Münchow, Eliseu Aldrighi
- Subjects
Grau de conversão ,Degree of conversion ,Temperatura de polimerização ,Resina composta ,Storage ,Solubilidade ,Sorção ,Armazenamento ,Dureza ,CIENCIAS DA SAUDE [CNPQ] ,Solubility ,Microhardness ,Resin composite ,Sorption ,Curing temperature - Abstract
FAPEMIG - Fundação de Amparo à Pesquisa do Estado de Minas Gerais As resinas compostas são amplamente utilizadas na prática odontológica para restaurar a forma, a função e a estética dos dentes. Elas podem ser manipuladas em diferentes temperaturas e devem resistir às condições da cavidade bucal. Este estudo “in vitro” avaliou o grau de conversão (FTIR/ATR), sorção e solubilidade (ISO 4049: 2000) e dureza superficial (Koop) de sete resinas compostas (Filtek Z100, Z250, 350, One Bulk Fill, Bulk Fill Flow, Universal e P60) polimerizadas em duas diferentes condições: 1 – temperatura: ambiente (25°C) ou refrigerada (5°C); e 2 – tempo de armazenamento: 7 dias e 30 dias. Para a obtenção das amostras foi utilizado um molde de silicone cilíndrico com dimensões internas de 6mm de diâmetro e 1mm de profundidade. As amostras foram polimerizadas por 20s utilizando-se um equipamento LED (VALO Cordless LED). O grau de conversão foi analisado por ANOVA on ranks e teste StudentNewman-Keuls. Os demais resultados foram analisados por ANOVA dois fatores para medidas repetidas e Teste de Tukey. A associação entre as características das resinas compostas e o potencial benéfico do uso dos materiais a 25°C ou a 5°C foi realizada por meio do teste Qui-quadrado. Os resultados foram correlacionados pelo teste de Correlação de Pearson. O nível de significância, para todas as análises, foi de 5%. Todos os materiais apresentaram maior grau de conversão a 25°C. Maior sorção e solubilidade foram observadas a 25°C e após 30 dias. Maiores resultados de dureza foram observados a 25°C e após 7 dias. Considerando a indicação clínica, os materiais indicados para a região posterior apresentaram maior potencial para aumentar a dureza quando armazenados em temperatura ambiente (p=0,047), enquanto os materiais de uso universal apresentaram maior potencial para redução da sorção e solubilidade à temperatura ambiente (p=0,047) Os materiais do tipo microhíbridos apresentaram maior potencial de redução da solubilidade quando comparados aos materiais nanoparticulados (p=0,047). As resinas com maior quantidade de partículas demonstraram maior capacidade de reduzir a solubilidade (p=0,008). Por fim, observou-se que quanto maior o grau de conversão, maior a possibilidade de se observar maiores valores de dureza superficial. Resin composites are widely used in dental practice to restore contour, function, and esthetics. They can be handled at different temperatures and must support the conditions of the oral cavity. This in vitro study evaluated the degree of conversion (FTIR/ATR), sorption and solubility (ISO 4049: 2000) and surface hardness (Koop) of seven composite resins (Filtek Z100, Z250, 350, One Bulk Fill, Bulk Fill Flow, Universal and P60) polymerized under two different conditions: 1 – temperature: ambient (25°C) or refrigerated (5°C); and 2 – storage: 7 days and 30 days. The samples were obtained using a cylindrical silicone mold with internal dimensions of 6mm in diameter and 1mm in depth and were polymerized for 20s using a LED device (VALO Cordless LED). The degree of conversion was analyzed by ANOVA on ranks and Student-Newman-Keuls test. The other results were analyzed by two-way ANOVA for repeated measures and Tukey's test. The association between the characteristics of resin composites and the beneficial potential of using the materials at 25°C or 5°C was performed using the Chisquare test. The results were correlated using the Pearson correlation test. The level of significance for all analyses was 5%. All materials showed higher degree of conversion at 25°C. Greater sorption and solubility were observed at 25°C and after 30 days. Greater hardness results were observed at 25°C and after 7 days. Considering the clinical indication, the materials indicated for the posterior region had greater potential to increase hardness when stored at room temperature (p=0.047), while materials for universal use preented greater potential to reduce sorption and solubility at room temperature (p=0.047) Microhybrid materials showed greater potential for reducing solubility when compared to nanoparticulate materials (p=0.047). Resins with greater amount of particles showed higher ability to reduce solubility (p=0.008). Finally, it was observed that the greater the degree of conversion achieved by the material, a higher hardness should be expected.
- Published
- 2021
6. Monomer conversion of composite dental resins photoactivated by a halogen lamp and a LED: a FT-Raman spectroscopy study
- Author
-
Luís Eduardo Silva Soares, Rick Rocha, Airton Abrahão Martin, Antonio L. B. Pinheiro, and Marcelo Zampieri
- Subjects
composites ,degree of conversion ,FT-Raman spectroscopy ,Chemistry ,QD1-999 - Abstract
Eighteen circular blocks of resins cured either by a LED or a halogen lamp (20, 40 and 60 s), had their top (T) and bottom (B) surfaces studied using a FT-Raman spectrometer. Systematic changes in the intensity of the methacrylate C=C stretching mode at 1638 cm-1 as a function of exposure duration were observed. The calculated degree of conversion (DC) ranged from 45.0% (B) to 52.0% (T) and from 49.0% (B) to 55.0% (T) for the LED and halogen lamp, respectively. LED and halogen light produced similar DC values with 40 and 60 s of irradiation.
- Published
- 2005
- Full Text
- View/download PDF
7. Light-curing units in dentistry - characterization and performance in the activation of resin composites and resin cements
- Author
-
Stella Sueli Lourenço Braga, Price, Richard Bengt, Soares, Carlos José, Silva, Gisele Rodrigues da, Soares, Priscilla Barbosa Ferreira, Shimokawa, Carlos Alberto Kenji, and Oliveira, Dayane Carvalho Ramos Salles de
- Subjects
Potência ,Transmissão de Luz ,Comprimento de Onda ,Resina Composta Bulk-Fill ,Wavelength ,Bulk-Fill Resin Composite ,Odontologia ,Photoinitiators ,Microhardness ,CIENCIAS DA SAUDE::ODONTOLOGIA::CLINICA ODONTOLOGICA [CNPQ] ,Dentistry ,Light transmission ,Fotoiniciadores ,Radiant Power ,Microdureza ,Degree of Conversion ,Grau de Conversão - Abstract
CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior A fotoativação é um passo importante nos procedimentos restauradores diretos e indiretos. Os equipamentos utilizados para este fim, as fontes fotoativadoras, apresentam características como potência, espectro de emissão, irradiância e formato do equipamento diferentes entre si. Essas características podem influenciar nos procedimentos odontológicos, o que torna importante o estudo e entendimento destes equipamentos para o melhor uso na associação aos materiais restauradores. O objetivo geral desta tese foi avaliar e caracterizar o desempenho de diferentes fontes fotoativadoras na ativação de restaurações diretas e indiretas. Três objetivos integram este estudo: Objetivo específico 1: avaliar o efeito do tipo de fonte fotoativadora e do preparo de amostras na microdureza e grau de conversão em diferentes profundidades e regiões de restaurações em dentes posteriores com resina composta bulk-fill. Objetivo específico 2: Avaliar a influência de diferentes cerâmicas, espessuras e tratamentos de superfície na transmissão de luz em diferentes comprimentos de onda violeta e azul. Objetivo específico 3: Avaliar o efeito da emissão de apenas luz violeta, apenas luz azul ou da combinação de ambas por uma fonte fotoativadora de múltiplos espectros, no grau de conversão de cimentos resinosos que apresentam diferentes fotoiniciadores. A partir destes estudos pode-se concluir que o preparo de amostras incluídas em resina de poliestireno para testes de dureza e grau de conversão reduzem a percepção de diferenças entre as diferentes técnicas, já na utilização de método sem inclusão e sem polimento da amostra é possível detectar diferenças produzidas pela fotoativação em áreas profundas da restauração, como caixas proximais de restaurações Classe II. De acordo com o segundo estudo, há uma rápida redução logarítmica em transmissão de luz à medida que a espessura de cerâmica aumenta, transmitindo pouca luz através de 1,5 mm de ambas as cerâmicas testadas. Nos comprimentos de onda curtos a transmissão de luz é ainda menor. A cerâmica Celtra Duo, após glaze, apresenta maior brilho de superfície comparado a IPS e.max CAD, porém não há correlação entre o brilho de superfície e a transmissão de luz. E por fim, demonstrou-se que não é necessária fonte fotoativadora de múltiplos picos para polimerizar o cimento resinoso Variolink Esthetic LC e, o cimento resinoso RelyX Veneer não tem seu grau de conversão beneficiado pela emissão de luz violeta. Photoactivation is an important step for direct and indirect restorative procedures. The light-curing units used for this purpose present characteristics such as radiant power, emission spectrum, irradiance, and equipment design which are different among themselves, and have influenced the procedures. The general objective of this thesis was to evaluate and characterize the performance of different light-curing units in the activation of direct and indirect restorations. Three objectives integrate this study: Specific objective 1: To evaluate the effect of the sample preparation and light-curing units on the Knoop hardness and degree of conversion at different depths and regions of bulk-fill resin-based composite restorations. Specific objective 2: To evaluate the influence of thickness and surface condition on the transmission of violet and blue light through two ceramics. Specific objective 3: To evaluate the effect of delivering isolated violet, blue, or a combination of violet and blue light from a polywave® light-curing unit (LCU) through ceramic on the degree of conversion (DC) of two resin cements with different photoinitiators. Based on the results of these studies, the following conclusions can be drawn: preparation methods that embedded the samples in polystyrene resin and polished the specimens reduced the differences between the KH and DC values obtained by different preparation techniques. The use of the NotPol method was able to detect differences produced by light activation in deeper areas. According to the second study, there is a rapid logarithmic decline in light transmission as the ceramic thickness increases means that little useful light is transmitted through 1.5 mm of either ceramic. Even less of the shorter wavelengths of light are transmitted. Celtra Duo glazed ceramic had a higher surface gloss compared to IPS e.max CAD, however there is no correlation between surface gloss and light transmission. Finally, the third study demonstrated that a polywave® light is not required to cure Variolink Esthetic LC, and RelyX Veneer does not benefit from receiving violet light from the polywave® light. Tese (Doutorado) 2023-07-30
- Published
- 2021
8. Evaluation of Physical-Mechanical properties of different Bulk-Fill composites / Avaliação das propriedades Físico-Mecânicas de diferentes compósitos Bulk-Fill
- Author
-
Lidiane Costa de Souza, Ezequias Costa Rodrigues Júnior, Suyane Maria Luna Cruz, Barbara Lima Tomaz, N S Rodrigues, Juliano Sartori Mendonça, Nayara de Oliveira Souza, Vicente de Paulo Aragão Saboia, and D A Cunha
- Subjects
Materials science ,Resin composite ,Significant difference ,Composite number ,Bulk fill ,General Medicine ,Indentation hardness ,Polymerization shrinkage ,Resin composite, Bulk-fill technique, Degree of Conversion, Polymerization shrinkage, micro-computed tomography ,Knoop hardness test ,Bulk-fill technique ,Composite material ,micro-computed tomography ,Degree of Conversion ,Shrinkage ,Volumetric shrinkage - Abstract
The aim of the study was to assess the degree of conversion (DC), microhardness, polymerization shrinkage stress (PSS) and volumetric contraction of two bulk-fill composites (SonicFill, Kerr Corporation, Orange, CA, USA - (SF) and Filtek BulkFill, 3M ESPE, St Paul, MN, USA - (FB)) and one conventional nanofiller resin composite (Z350XT – 3M ESPE, St Paul, MN, USA) inserted incrementally (Z350I) or in bulk (Z350B). Micro-Raman spectroscopy, Knoop microhardness, PSS test and micro-computed tomography technique (μCT) were used to evaluate the resin composites. Data were analyzed with one-way ANOVA followed by Tukey’s post hoc test (α = 0.05). DC was not affected by the type of the composite, excepted when conventional resin composite was inserted in a single increment (p = 0.002). FB and Z350I showed higher microhardness values than Z350B (p = 0,003), while SF showed no statistically significant difference to the other resin composites. No statistical differences were found among the composites regarding to PSS (p = 0.104) and volumetric shrinkage (p = 0.258). Therefore, it can be concluded that bulk-fill and conventional resin composites tested present similar properties. Thus, shorter time required for the use associated with simplified operative technique are considered clinical advantages of bulk-fill composites.
- Published
- 2021
9. Estabilidade de cor de resinas compostas com diferentes valores de croma : correla??o do grau de convers?o com ?E e elui??o de mon?meros
- Author
-
Cardoso, Laura Irgang and Burnett Jr., Luiz Henrique
- Subjects
ODONTOLOGIA [CIENCIAS DA SAUDE] ,Resina Composta ,Grau de Convers?o ,Elui??o de Mon?meros ,Monomer Elution ,Color ,Cor ,Degree of Conversion ,Composite Resins - Abstract
Objetivos: avaliar a estabilidade de cor, o grau de convers?o de mon?meros e a elui??o de BisGMA e UDMA de tr?s marcas comerciais de resina composta, quando imersas em ?gua destilada, nos tempos imediato, 24h, 30 dias e 180 dias. Materiais e m?todos: foram confeccionados cinco corpos-de-prova de cada croma de resina estudada para avalia??o da estabilidade de cor atrav?s de espectrofotometria (Easyshade 4.0, Vita) e tr?s corpos de prova das mesmas resinas para avalia??o do grau de convers?o de mon?meros (FTIR). Cada incremento de resina dos esp?cimes foi fotopolimerizado por 20s com um LED poliwave e esses foram, ent?o, armazenados em eppendorfs com ?gua destilada ap?s a fotoativa??o. Um padr?o de escala de cores no material estudado foi confeccionado nos moldes da Escala Vita. A elui??o dos componentes UDMA e BisGMA foi analisada atrav?s de cromatografia l?quida com espectr?metro de massa (LC-MS/MS). Os seguintes per?odos foram estudados, imediato, 24h, 30 dias e 180 dias. Resultados: Todas as resinas estudadas apresentaram altera??o de cor em rela??o ao padr?o. O teste de ANOVA de tr?s vias permitiu observar que a intera??o Tempo/Marca comercial/cor foi significativa (p=0,0001). A marca comercial Empress Direct foi a ?nica a apresentar ?E?2,7 no per?odo de 180 dias nos cromas B1 e A1. Houve correla??o significativa direta entre grau de convers?o e ?E no tempo de 30 dias e inversa no tempo de 180 dias. Existe correla??o significativa entre grau de convers?o e elui??o UDMA. Conclus?o: O grau de convers?o de mon?meros dos comp?sitos estudados tem correla??o significativa direta com a estabilidade de cor no per?odo de 30 dias e inversa no per?odo de 180 dias. Existe correla??o significativa inversa entre elui??o de UDMA e grau de convers?o de mon?meros. Signific?ncia cl?nica: O grau de convers?o de mon?meros das resinas compostas tem correla??o significativa com a estabilidade de cor ao longo do tempo e com a elui??o de UDMA. Objectives: To evaluate the color stability of three commercial brands of composite resins when immersed in distilled water, within 24 hours, 30 days and 180 days, as well as the degree of monomer conversion and BisGMA and UDMA component elimination. Methods: Five specimens of each resin chroma were made for color stability evaluation, and three specimens for degree of monomer conversion evaluation. Each increment of resin in the specimens was light cured for 20s using a polywave LED and these were then stored in eppendorfs with distilled water after photoactivation. A color scale pattern was made from the material studied, following the Vita (Vita) scale. For color analysis an Easyshade 4.0 (Vita) spectrophotometer was used, while the degree of monomer conversion was assessed by FTIR and the elution of the UDMA and BisGMA components was analyzed by liquid chromatography with mass spectrometer. The following time periods were studied, immediately, 24h, 30 days and 180 days. Results: All resins studied showed a color change from the standard. The 3-way analysis of variance revealed that the interaction between time/color/brand was sisgnificant (p=0,0001). Empress Direct was the only one to display ?E?2,7over the 180 days period on chromas B1 and A1. There was a significant direct correlation between degree of conversion and ?E in 30 days and inverse in 180 days. There is a highly significant correlation between degree of conversion and UDMA elution. Conclusion: The degree of conversion of the studied composites has a significant direct correlation with color stability in the period of 30 days and inverse in the period of 180 days, suggesting a stabilization of the material over time. There is a significant inverse correlation between UDMA elution and degree of conversion of monomers. Clinical Significance: The degree of monomer conversion of composite resins has a significant correlation with color stability over time and with the elution of UDMA. Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES
- Published
- 2020
10. Efeito de diferentes intensidades de fotopolimerização nas propriedades de resinas compostas bulk fill e convencionais
- Author
-
Brandão, Felipe Suaki, Universidade Estadual de Ponta Grossa, Universidade Federal de Minas Gerais, Gomes, João Carlos, Pupo, Yasmine Mendes, Calixto, Abraham Lincolm, and Albuquerque, Rodrigo de Castro
- Subjects
Grau de conversão ,Resina Composta ,Composite resin ,Polymerization Shrinkage ,Citotoxicidade ,CIENCIAS DA SAUDE::ODONTOLOGIA [CNPQ] ,Citotoxicity ,Contração de polimerização ,Degree of Conversion ,Fotoativação ,Light-curing - Abstract
Submitted by Angela Maria de Oliveira (amolivei@uepg.br) on 2020-02-07T18:32:41Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Felipe Suaki Brandão.pdf: 2178021 bytes, checksum: 0357c2081603f18f08e622d4a9267a04 (MD5) Made available in DSpace on 2020-02-07T18:32:41Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Felipe Suaki Brandão.pdf: 2178021 bytes, checksum: 0357c2081603f18f08e622d4a9267a04 (MD5) Previous issue date: 2018-02-19 O objetivo do presente estudo foi avaliar os efeitos da intensidade de fotoativação com LED de alta potência nas propriedades de resinas compostas bulk fill e convencionais. Foram selecionadas quatro resinas compostas: 2 bulk fill (Filltek Bulkfill e Tetric N-Ceram), e 2 convencionais (Z350xt e a Palfique LX5). Dois protocolos de fotoativação foram determinados, utilizando o aparelho VALO LED Cordless, a intensidade Standard (1000m/cm²) por dez segundos e a intensidade Xtra (3200 mW/cm²) por três segundos. Foi padronizado para o grupo de resinas bulk fill a espessura de 4mm e 2mm para o grupo de resinas nanoparticuladas. As propriedades avaliadas foram sorção e solubilidade em água, microdureza Vickers, citotoxicidade, grau de conversão, contração de polimerização e alteração térmica. Os resultados do grau de conversão, microdureza Vickers e citotoxicidade apontaram de forma geral que a fotoativação mais intensa não obteve diferença sobre o modo Standard, enquanto que a sorção e solubilidade em água, a contração de polimerização e a alteração térmica apresentaram diferenças estatisticas. The objective of the present study was to evaluate the effects of high power LED light activation on the properties of bulk fill and nanoparticulate composites. Four composite resins were selected: 2 bulk fill (Filltek Bulkfill and Tetric N-Ceram), and 2 conventional fillers (Z350xt and Palfique LX5). Two photoactivation protocols were determined using the VALO LED Cordless device, the standard intensity (1000m / cm²) for ten seconds and the Xtra intensity (3200 mW / cm²) for three seconds. It was standardized for the group of resins bulk fill the thickness of 4mm and 2mm for the group of nanoparticulate resins. The evaluated properties were sorption and solubility in water, Vickers microhardness, cytotoxicity, degree of conversion, shrinkage of polymerization and thermal alteration. The results of the conversion degree, Vickers microhardness and cytotoxicity showed that the most intense photoactivation did not differ in the standard mode, whereas water sorption and solubility, polymerization contraction and thermal alteration presented statistical differences.
- Published
- 2018
11. EFEITO DA DENSIDADE DE ENERGIA DE FOTOATIVADORES DE ALTA POTÊNCIA NAS PROPRIEDADES FÍSICO-MECÂNICAS DE UMA RESINA ORTODÔNTICA
- Author
-
Arana, Andrés Fernando Montenegro, Farago, Paulo Vitor, Arrais, Cesar Augusto Galvão, Pupo, Yasmine Mendes, Stanislawczuk, Rodrigo, Gomes, Giovana Mongruel, and Coelho, Ulisses
- Subjects
Grau de conversão ,Orthodontic appliances ,Degree of conversion ,CIENCIAS DA SAUDE::ODONTOLOGIA [CNPQ] ,Brackets ortodônticos ,Cimentos ortodônticos ,Orthodontic resin ,Resistência ao cisalhamento ,Colagem de braquetes ,Orthodontics ,Orthodontic Brackets Photopolimerization ,Aparelhos ortodôntico ,Microhardness ,Microdureza ,Shear Strength ,Ortodontia ,Orthodontic bracket - Abstract
Submitted by Angela Maria de Oliveira (amolivei@uepg.br) on 2018-03-01T13:44:47Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Andrés Fernando Montenegro.pdf: 11976346 bytes, checksum: fa909dec838336e8c5a4ed73180bb65b (MD5) Made available in DSpace on 2018-03-01T13:44:47Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Andrés Fernando Montenegro.pdf: 11976346 bytes, checksum: fa909dec838336e8c5a4ed73180bb65b (MD5) Previous issue date: 2017-10-16 O objetivo deste estudo foi verificar o efeito da densidade de energia e o tempo de exposição de fotopolimerizadores LED de terceira geração em uma resina ortodôntica disponível comercialmente nos valores de microdureza, cisalhamento, índice de remanescente de resina e grau de conversão. Para tanto, foram realizados 3 experimentos: Experimento 1, o objetivo foi avaliar o grau de conversão (DC) e microdureza vickers (MHV) da resina ortodôntica utilizando dois LEDs de terceira geração, assim como, protocolos de fotoativação diferentes. Foram necessários 80 brackets cerâmicos e 80 brackets metálicos, sendo divididos em 16 grupos experimentais (n=10) tendo os seguintes grupos para cada LED: um grupo controle, diminuição da metade do tempo de exposição do grupo controle, um quarto do tempo do grupo controle, função turbo ou plasma para os LEDs Bluephase e Valo, respetivamente. Imediatamente após a polimerização, foram realizados os ensaios de DC e MHV. O experimento 2, objetivou verificar a influência de diferentes densidades de energia emitidas por dois fotoativadores LED de alta potência nas propriedades físicas e mecânicas de uma resina ortodôntica em brackets metálicos. Foram necessários 80 pré-molares superiores, sendo usadas as superfícies vestibulares dos dentes para a colagem dos 80 brackets metálicos. Os dentes foram divididos aleatoriamente em 8 grupos experimentais (n=10), sendo: um grupo controle, redução da metade do tempo de exposição do grupo controle, um quarto do tempo do grupo controle, função plasma ou turbo para cada LED estudado, sendo Valo e Bluephase. Após 24 horas da polimerização, foram realizados os testes de cisalhamento (SBS), índice remanescente de resina (ARI) e MHV. O objetivo do experimento 3 foi verificar a influência de diferentes densidades de energia depositadas por dois fotoativadores LED diferentes de alta potência nas propriedades físicas e mecânicas de uma resina ortodôntica em brackets cerâmicos. Foram necessários 80 dentes pré-molares superiores hígidos, sendo utilizadas as superfícies linguais ou palatinas dos dentes para colagem dos 80 brackets cerâmicos. Os dentes foram divididos aleatoriamente em 8 grupos experimentais (n=10), foram formados grupos iguais para cada LED Valo e Bluephase: um grupo controle, diminuição da metade do tempo de exposição do grupo controle, um quarto do tempo do grupo controle, função turbo do LED Bluephase ou plasma do LED Valo. Após 24 horas da polimerização, foram realizados os testes de SBS, ARI e MHV. Os resultados de cada experimento foram analisados através de testes estatísticos específicos, para determinar se houve ou não diferença estatisticamente significativa. Para o experimento 1 foram realizados ANOVA de duas vias e teste de Tukey (α=0,05), para o experimento 2 e 3 foram realizados Anova de duas vias com testes de Tukey (α=0,05). O experimento 1 mostrou que os grupos dos brackets cerâmicos tem baixa variação, porém pequenas mudanças no aumento dos valores da energia aplicada em Joules totais aumentam os valores de DC e MHV, nos brackets metálicos pelo fato de impedir a passagem da luz o DC e HVK diminuem significativamente, permanecendo dentro dos parâmetros considerados normais. O experimento 2 mostrou que ambos LED utilizados foram efetivos tanto na função standard como na turbo ou plasma, sendo que as funções turbo ou plasma ofereceram resultados similares aos do controle, efetivando mesmo com a redução do tempo para a polimerização dos brackets metálicos. No experimento 3 não houve diferença estatisticamente significativa nos grupos analisados. Os LEDs estudados proporcionaram valores suficientes de Joules em alguns grupos experimentais sendo este suficiente para atingir bons valores no DC, SBS e MHV. O uso de LEDs com uma potência adequada, sendo o mínimo de 1200 mW/cm2, ou o uso de uma potência elevada de entre 2400 a 3200 mW/cm2 e um curto período de tempo de exposição entre 3 a 6 segundos, são efetivos para a colagem de acessórios ortodônticos. The objective of this study was to verify the effect of energy density and the time of exposure of third generation LED light curing agents on a commercially available orthodontic resin in the values of microhardness, shear, resin remaining index and degree of conversion. Three experiments were carried out: Experiment 1, the objective was to evaluate the degree of conversion (DC) and microhardness vickers (MHV) of the orthodontic resin using two third generation LEDs, as well as different photoactivation protocols. 80 ceramic brackets and 80 metallic brackets were required and divided into 16 experimental groups (n=10), with the following groups for each LED: control group, one half, one quarter of the control group time, turbo or plasma function for the Bluephase and Valo LEDs, respectively. Immediately after the polymerization, the DC and MHV assays of the specimens were performed. The experiment 2, aimed to verify the influence of different energy densities emitted by two high power LED photoactivators on the physical and mechanical properties of an orthodontic resin in metallic brackets. For this experiment, 80 carious cavity-free, superior human premolar teeth were used, and the buccal surfaces of the teeth were used for the bonding of the 80 metal brackets. The teeth were randomly divided into 8 experimental groups (n=10), with the following groups being a control group, half the time of exposure of the control group, one quarter of the time in the control group, plasma or turbo function for each LED studied, being Valo and Bluephase. After polymerization, the teeth and specimens were stored 24h at 37°C to perform the shear tests (SBS), resin remaining index (ARI) and MHV. The objective of experiment 3 was to verify the influence of different energy densities deposited by two different LED light-curing on the physical and mechanical properties of an orthodontic resin in ceramic brackets. For this experiment, it was necessary to have 80 carious free upper premolar human teeth, using the lingual or palatine surfaces of the teeth for bonding the 80 ceramic brackets. The teeth were randomly divided into 8 experimental groups (n=10), equal groups were formed for each Valo and Bluephase LEDs: one control group, one half-time control group exposure time, one-fourth time control group, function LED Bluephase turbo or LED Valo Plasma. After polymerization, the teeth and specimens were stored 24 hours at 37°C to perform the SBS, ARI and MHV tests. The results of each experiment were analyzed by specific statistical tests to determine whether or not there was a statistically significant difference. For experiment 1, 2 and two-way ANOVA and Tukey's test (α=0.05) were performed. Experiment 1 showed that the groups of ceramic brackets have low variation, but small changes in the increase of the values of the applied energy in total Joules increase the values of DC and MHV in the metallic brackets because it prevents the passage of light the DC and HVK decrease significantly, remaining within the parameters considered normal. Experiment 2 showed that both LEDs were effective both in the standard function and in the turbo or plasma, and the turbo or plasma functions gave similar results to the control, even effecting with the reduction of the time for the polymerization of the metal brackets. In the experiment 3 there was no statistically significant difference in the analyzed groups. The studied LEDs provided sufficient values of Joules in some experimental groups being sufficient to reach good values in DC, SBS and HVK. The use of LEDs with adequate power, being at least 1000 mW/cm2, or the use of a high power of between 2400 and 3200 mW/cm2 and a short period of exposure of between 3 to 6 seconds, are sufficient for the bonding of orthodontic accessories.
- Published
- 2017
12. Effect of endodontic sealers on the bond strength of fibreglass posts and the degree of conversion of two resin cements
- Author
-
Bohrer, Thaís Camponogara, Kaizer, Osvaldo Bazzan, Skupien, Jovito Adiel, and Morgental, Renata Dornelles
- Subjects
Grau de conversão ,Push-out ,Pinos de fibra ,Degree of conversion ,CIENCIAS DA SAUDE::ODONTOLOGIA [CNPQ] ,Eugenol ,Push-out bond strength test ,Fibreglass post ,Endodontic sealer ,Cimentação ,Cimentos endodônticos ,Luting - Abstract
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES Restoring dental function after partial loss of the coronary structure depends mainly of post retainer adhesive strength. However, several factors may affect the adhesion between the root dentin and the radicular post used including the endodontic sealers used for root canal obturation during endodontic treatment. Therefore, the objective of this study is to evaluate the effect of two endodontic sealers on push-out bond strength between fibreglass posts and root canal wall after different storage times and verify the influence of the endodontic sealers on the degree of conversion of resin cements. For this study, 180 bovine teeth were endodontically treated using two endodontic sealers, eugenol-based (Endofill) or epoxy resin-based (AH Plus). Subsequently, the specimens were stored in 100% relative humidity at 37 °C for 24 h, 6 or 12 months. After the respective storages times, the root canals were prepared for fibreglass post cementation using two resins cements, RelyX U200 or Multilink Automix. The push-out test and the analysis of failures were performed. For the degree of conversion analysis with a Raman microscope. The samples were prepared using only resin cement or resin cement and endodontic sealer. Finally, the push-out data were subjected to statistical analysis and the percentages of degree of conversion were calculated. The AH Plus sealer obtained the highest values of push out bond strength at 24 h and 6 months. There was no difference between the values of AH Plus and Endofill sealer at time 1 year (p < 0.05). Moreover, the degree of conversion was affected by the endodontic sealers used. Therefore, the use of eugenol-based sealer is not recommended because it affects the push-out strength of fibreglass posts. O restabelecimento da função dentária após a perda da porção coronária depende, em grande parte, da resistência adesiva dos pinos intrarradiculares. Entretanto, vários fatores podem afetar a adesão entre a dentina radicular e o retentor intrarradicular utilizado, um deles é o cimento utilizado para obturação do canal radicular na endodontia. Em vista disso, o objetivo desse estudo é avaliar o efeito de dois cimentos endodônticos em diferentes tempos de armazenamento na resistência adesiva entre pinos de fibra e as paredes do canal radicular, e verificar a influencia de cimentos endodônticos no grau de conversão dos cimentos resinosos. Para a realização do estudo, 180 dentes bovinos foram tratados endodonticamente utilizando dois cimentos endodônticos, à base de eugenol (Endofill) ou à base de resina epóxica (AH Plus). A seguir, os espécimes foram armazenados em estufa a 37 °C nos tempos 24 h, 6 meses e 12 meses. Decorrido o tempo de armazenamento, os canais radiculares foram preparados para a cimentação do pino de fibra utilizando dois cimentos resinosos, RelyX U200 ou Multilink Automix. O teste de push-out e a análise das falhas foram realizados. Para a análise do grau de conversão foi utilizado o microscópio Raman. As amostras foram preparadas utilizando somente cimento resinoso ou cimento resinoso e cimento endodôntico. Finalmente, os dados do teste de push-out foram submetidos à análise estatística e as porcentagens do teste de grau de conversão foram calculadas. O cimento AH Plus obteve os maiores valores de push-out nos tempos 24 h e 6 meses. Não teve diferença significativa entre os cimentos AH Plus e Endofill após 12 meses (p < 0,05). Além disso, o grau de conversão foi afetado pelo cimento endodôntico à base de eugenol. Portanto, o uso de cimentos endodônticos à base de eugenol não é recomendado, pois afeta a resistência adesiva dos cimentos resinosos.
- Published
- 2017
13. Effect of pre-heating and post-curing on mechanical properties and degree of conversion of an experimental composite reinforced with glass fiber
- Author
-
Almeida, Letícia Nunes de, Fonseca, Rodrigo Borges, Souza, João Batista de, and Menezes, Murilo de Souza
- Subjects
Grau de conversão ,ODONTOLOGIA [CIENCIAS DA SAUDE] ,Degree of conversion ,Intrarradicular post ,Pós-polimerização ,Pinos intrarradiculares ,Mechanical properties ,Fiber-reinforced composites ,Post-curing ,Propriedades mecânicas ,Compósitos reforçados por fibra - Abstract
O aquecimento prévio à polimerização e a pós-polimerização podem melhorar propriedades mecânicas em compósitos, embora inexistam estudos em compósitos reforçados com fibra. O objetivo deste estudo foi avaliar o efeito do pré- aquecimento e da pós-polimerização em autoclave e microondas na resistência flexural (RF), resistência à tração diametral (RTD), microdureza knoop (KHN) e grau de conversão (GC) de um compósito experimental reforçado por fibra de vidro. O material experimental foi confeccionado com 30% de fibras de vidro (3 mm), 22,5% de matriz resinosa (40/60 Bis-GMA/TEGDMA) e 47,5% de partículas de silicato de bário. Seis grupos experimentais foram criados pela interação entre os fatores em estudo: aquecimento, em dois níveis (controle sem aquecimento e aquecimento a 60oC) e pós-polimerização, em 3 níveis (fotopolimerização convencional sem pós- polimerização, autoclave (120oC por 15 minutos) e microondas (540 W por 5 minutos). Os grupos foram: F - fotopolimerização à 1500 mW/cm2 por 40 segundos; F+M - fotopolimerização e pós- polimerização em microondas; F+A - fotopolimerizacão e pós-polimerização em autoclave; AQ+F - aquecimento do compósito previamente à fotopolimerização; AQ+F+M - aquecimento previamente à fotopolimerização e pós-polimerização em microondas; AQ+F+A - aquecimento previamente à fotopolimerização e pós-polimerização e autoclave. O aquecimento foi realizado em estufa digital por 5 minutos a 60oC. Dez amostras de RF nas dimensões de 25 x 2 x 2 mm e de RTD nas dimensões de 3 x 6 mm foram testadas em máquina de ensaio universal Instron 5965, a 0,5mm/min. O teste de KHN foi realizado em amostras de 3 x 6 mm com carga de 50 g por 30 s, totalizando 50 indentações por grupo. O GC foi obtido através de Espectroscopia de Infravermelho por Transformada de Fourrier (FTIR) em cinco amostras. Os dados foram analisados por um modelo linear geral fatorial 2x3 e testes de ANOVA e Tukey (α=0,05). A análise fatorial mostrou interação significativa entre os fatores apenas para RTD (p=0,0001); o fator pré-aquecimento foi significante para RF (p=0,0001), RTD (p=0,020) e KHN (p=0,0001); o fator pós-polimerização foi significante para KHN (p=0,0001). Os testes de ANOVA e Tukey mostraram diferença estatística entre os grupos para RTD (p = 0,001: AQ+F ≥ AQ+F+M = F+A = AQ+F+A = F+M ≥ F), RF (p = 0,016: AQ+F+M ≥ AQ+F+A = AQ+F = AQ+A ≥ F+M ≥ F) e KHN (p = 0,0001: AQ+F+M ≥ AQ+F+A = F+A= F+M ≥ AQ+F ≥ F). Os resultados de GC não apresentaram diferença estatisticamente significante. Através do coeficiente de correlação de Pearson foi possível observar correlação positiva significante entre o GC e RTD (r = 0,473, p = 0,008) e entre RTD e RF (r = 0,263, p = 0,042) . O pré- aquecimento e a pós-polimerização mostraram-se favoráveis para promover melhores propriedades mecânicas do compósito reforçado por fibra estudado, sendo específicos para cada propriedade analisada. The pre-heating and post-curing can improve the mechanical properties of composites, even though there be no studies of fiber reinforced composites. The aim of this study was to evaluate the effect of pre-heating and post-curing autoclave and microwave in flexural strength (FS), diametral tensile strength (DTS), knoop microhardness (KHN) and degree of conversion (DC) of a experimental fiber- reinfoced composite. The experimental material was prepared with 30% glass fibers (3 mm), 22.5% of the resin matrix (40/60 Bis-GMA / TEGDMA) and 47.5% barium silicate particles. Six experimental groups were created by the interaction between the factors under study: heating, on two levels (without heating and heating at 60°C) and post-curing in 3 levels (conventional curing without post-curing, autoclave (120°C for 15 minutes) and microwaves (540 W for 5 minutes) The groups were: F - curing at 1500 mW/cm2 for 40 seconds; F + M - curing and post- polymerization in microwave; F + A - curing and post-curing in an autoclave , AQ + F - the composite heating prior to curing, AQ + F + M - heating prior to curing and post-curing in microwave;. AQ + F + A - heating prior to curing and post-curing and autoclave heating was conducted digital oven for 5 minutes at 60°C. Ten samples of the RF dimensions 25 x 2 x 2 mm and DTS in dimensions of 3 x 6 mm were tested in a universal testing machine Instron 5965, 0.5 mm/min. the KHN test was performed on samples of 3 x 6 mm with a load of 50 g for 30 sec, totaling 50 indentations per group. GC was obtained by Spectroscopy Fourier Transform Infrared (FTIR) on 5 samples. Data were analyzed by a factorial 2x3 and general linear model ANOVA and Tukey tests (α = 0.05). Factor analysis showed significant interaction between the factors just for RTD (p = 0.0001); preheating was significant factor for RF (p = 0.0001), RTD (p = 0.020) and KHN (p = 0.0001); post-curing factor for KHN was significant (p = 0.0001). ANOVA and Tukey tests showed statistically significant differences between groups for DTS (p = 0.001: AQ + F ≥ AQ + F + M = F + A = AQ + F + A = F + M ≥ F), FS (p = 0.016: AQ + F + M ≥ AQ + F + A + F = AQ = AQ + A + M ≥ F ≥ F) and KHN (p = 0.0001: AQ + F + M ≥ AQ + A + F = F = F + A + M ≥ F ≥ M + AQ). GC results showed no statistically significant difference. Through the Pearson correlation coefficient was observed significant positive correlation between the GC and RTD (r = 0.473, p = 0.008) and between DTS and FS (r = 0.263, p = 0.042). The pre-heating and post- polymerization were shown to be favorable to promote better mechanical properties of fiber reinforced composite by studied, specific for each property being analyzed. Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES
- Published
- 2016
14. Effect of inclusion of copper nanoparticles in etch and rinse adhesive systems on microbiological and mechanical properties, and the durability of resin–dentine interfaces
- Author
-
Reyes, Mario Felipe Gutiérrez, Farago, Paulo Vitor, Loguércio, Alessandro Dourado, Hass, Viviane, and Reis, Alessandra
- Subjects
atividade antimicrobiana ,liberação de cobre ,antimicrobial activity ,resin–dentine bond strength ,nanoleakage ,ultimate tensile strength ,grau de conversão ,degree of conversion ,CIENCIAS DA SAUDE::ODONTOLOGIA [CNPQ] ,sorção e solubilidade ,dentin ,nanoinfiltração ,copper release ,dentina ,adesivos convencionais ,resistência a tração ,etch-and-rinse ,resistência de união ,adhesives ,water sorption and solubility - Abstract
Made available in DSpace on 2017-07-24T19:22:05Z (GMT). No. of bitstreams: 1 FELIPE GUTIERREZ REYES.pdf: 2973646 bytes, checksum: 0e8c702449c97c861e9f0314e3b69e2f (MD5) Previous issue date: 2016-02-23 Objectives: This study evaluated the effect of addition of copper nanoparticles at different concentrations into a simplified etch-and-rinse (ER) adhesive system (Ambar [AM]) on antimicrobial activity (AMA), degree of conversion of adhesives discs (DC-d) and dentin-resin interface (DC-i), the ultimate tensile strength (UTS), 28-day cumulative water sorption (WS), solubility (So) and copper release (CR) as well as immediate (IM) and 1-year (1Y) resin–dentine bond strength (μTBS) and nanoleakage (NL). Methods: Seven experimental adhesive systems were formulated according to the addition of copper nanoparticles (0 [control], 0.0075, 0.015, 0.06, 0.1, 0.5 and 1%) in AM adhesive system. We tested the antimicrobial activity of synthesized adhesives against Streptococcus mutans using agar diffusion assays. For DC-d, specimens were constructed and tested after 24 h for FTIR and micro-Raman spectroscopy. For UTS, specimens were tested after 24 h and 28 days. For WS and So, after specimens build-up, they were stored in water and the properties measured for 28 days. For CR, specimens were stored in 2% nitric acid solution and the properties were measured for 28 days. The occlusal enamel of thirty-five molars was removed and adhesives were applied to dentine surface after 37% phosphoric acid etching. After composite resin build-ups, specimens were longitudinally sectioned to obtain resin–dentine bonded sticks (0.8 mm2). Specimens were tested in tension at 0.5 mm/min in IM or 1Y (μTBS). For NL, 2 bonded sticks from each tooth were prepared and analyzed under SEM in IM or 1Y. For DC-i, 2 bonded sticks were prepared and analyzed under micro-Raman spectroscopy. The μTBS and NL data of each adhesive were subjected to two-way repeated measures ANOVA. For UTS, WS, So, copper release, DC-d and DC-i data of each adhesive were subjected to a one-way ANOVA. Tukey’s post hoc test was used for pair-wise comparisons (α = 0.05). Results: The addition of copper nanoparticles provided antimicrobial properties to the adhesives at all concentrations (p < 0,05), and did not influence UTS, WS and SO (p > 0.05). Higher CR was observed in adhesives with higher concentration of copper nanoparticles (p < 0.05). The addition of 1% of copper nanoparticles decreased the DC-d and DC-i significantly. After 1Y, significant reductions of μTBS and increases of NL were observed in the control group (p < 0.05). Reductions of μTBS and increase of NL over time were not observed for copper-containing adhesives.Conclusions: The addition of copper nanoparticles in concentrations up to 0.5% in the simplified ER Ambar adhesive system may be an alternative to provide antimicrobial properties, increase the long-term stability of resin–dentine interfaces, 12 without reducing adhesives’ mechanical properties evaluated. Objetivos: Este estudo avaliou o efeito da adição de nanopartículas de cobre, em diferentes concentrações, em um sistema adesivo convencional (CON) simplificado Ambar [FGM] sobre a atividade antimicrobiana (AAM), grau de conversão de corpos de prova de adesivos (GC-c) e na interface de união a dentina (GC-i), resistência máxima à tração (RT), sorção cumulativa de água (SO), solubilidade (SB) e liberação de cobre (LC) durante 28 dias, bem como a resistência de união (RU) e nanoinfiltração (NI) na interface de união à dentina nos tempos imediatos (IM) e após 1 ano (1A). Material e métodos: Sete sistemas adesivos experimentais foram formulados de acordo com a adição de nanopartículas de cobre (0 [controle], 0,0075, 0,015, 0,06, 0,1, 0,5 e 1%) no sistema adesivo Ambar. Foi testada a atividade antimicrobiana dos adesivos formulados contra Streptococcus mutans por meio de ensaios de difusão em ágar. Para GC-c, as amostras foram construídas e testadas após 24 h por meio de espectrofotometria no infravermelho com Transformação de Fourier (FTIR) e espectroscopia de micro-Raman. Para RT, as amostras foram testadas depois de 24 horas e 28 dias. Para SO e SB, depois de confeccionados os espécimes, eles foram armazenados em água e as propriedades medidas por 28 dias. Para LC, as amostras foram armazenadas em solução de ácido nítrico a 2% e as propriedades medidas durante 28 dias. O esmalte oclusal de trinta e cinco molares foi removido e os adesivos foram aplicados na superfície da dentina depois de condicionamento com ácido fosfórico a 37%. Depois de restaurações de resina composta, os espécimes foram seccionados longitudinalmente para se obter espécimes (palitos) de resina-dentina (0,8 mm2). Os espécimes foram testados em tensão a 0,5 mm/min no IM ou 1A (RU). Para NI, 2 espécimes de cada dente foram preparadas e analisadas em MEV e testados no IM ou 1A. Para GC-i, 2 espécimes foram preparados e analisados sob espectroscopia de micro-Raman. Os dados do RT foram analisados por uma análise de variância de 2 fatores. Para AAM, SO, SB, e liberação de cobre, os dados foram analisados por análise de variância de fator único, e para RU e NI os dados foram submetidos a análise de variância de 2 fatores para medidas repetidas. Também foi feito o teste post hoc de Tukey para múltiplas comparações. A significância estatística foi predefinida em α = 0,05.Resultados: A adição de nanopartículas de cobre adicionou propriedades antimicrobianas aos adesivos em todas as concentrações (p < 0,05), e não influenciou a RT, SO e SB (p > 0,05). LC elevadas foram observadas em adesivos com maior concentração de nanopartículas de cobre (p < 0,05). A adição de 1% de 10 nanopartículas de cobre diminuiu significativamente o GC-c e GC-i. Após 1 ano, decréscimos significativos de RU e aumentos de NI foram observados no grupo controle (p < 0,05). Decréscimos significativos de RU e aumentos de NI não foram observados nos adesivos contendo cobre (p > 0,05). Conclusões: A adição de nanopartículas de cobre em concentrações de até 0,5% no sistema adesivo convencional simplificado Ambar pode ser uma alternativa para adicionar atividade antimicrobiana e aumentar a estabilidade a longo prazo das interfaces resina-dentina, sem comprometer as propriedades mecânicas dos adesivos.
- Published
- 2016
15. Influence of light curing on the degree of conversion in the curing resin cements and retention of fiber glass radicular dentin
- Author
-
Boing, Thaynara Faelly, Gomes, Osnara Maria Mongruel, Gomes, João Carlos, Pereira, Stella Kossatz, and Franco, Ana Paula Gebert
- Subjects
bond strength ,espectroscopia Raman ,grau de conversão ,degree of conversion ,CIENCIAS DA SAUDE::ODONTOLOGIA [CNPQ] ,Raman spectroscopy ,resin cement ,resistência de união ,cimento resinoso - Abstract
Made available in DSpace on 2017-07-24T19:21:56Z (GMT). No. of bitstreams: 1 Thaynara Faelly Boing.pdf: 1819408 bytes, checksum: 786153168eac139f5217b66b5e8291d4 (MD5) Previous issue date: 2015-02-24 Coordenação de Aperfeiçoamento de Pessoal de Nível Superior The purpose of this study was to evaluate the influence of two polymerization techniques on conversion degree (DC) of the resin cements and on retention of glass fiber posts in the different thirds of root dentine. For this purpose, it was selected twenty extracted mandibular premolars, which were sectioned after the cementumenamel junction, and the roots were treated endodontically. After a week, the posts spaces were prepared and the roots were randomly divided into two groups (n=10),according to the mode of polymerization of the dual resin cement (RelyX™ U200 – 3M ESPE): GFC - activation mode Continuous and GFS - activation mode Soft start (Ramp). The intraradicular posts (White Post DC - FGM) were cemented according to the manufacturer's recommendations. After storage in distilled water at 37 ° C for one week, the roots were cross-sectioned in six discs of 1 mm thickness each, and the thirds coronary (TC), medium (TM) and apical (TA) of the root canal were identified.To assess the degree DC the specimens were submitted to Micro-Raman spectroscopy, and the bond strength by the push-out test at a cross-head speed of 0.5 mm/min. The data were be statistically analyzed by two-way ANOVA and Tukey’s test for contrast of means (α = 0.05). The average values of degree of conversion and standard deviation (SD ) for each group were: GFC : 75.66 ± 5.51 , GFS : 77.38 ± 5.66, compared to thirds GFC : TC : 73.87 ± 5.50, TM : 74.59 ± 4.86 and TA : 78.50 ± 5.57 , GFS : TC : 77.79 ± 6.16 , TM : 77.14 ± 5.77 and TA : 77.21 ± 5.79 . There was no significant difference between the techniques of photoactivation or between root thirds. For bond strength ( MPa ) mean (SD) values and standard deviation were : GFC : 18.46 ± 6.23 , GFS : 22.88 ± 5.76 , compared to thirds , GFC : TC : 14.32 ± 3.40 , TM : 15.75 ± 3.20 , TA : 25.30 ± 4.89 , GFS : TC : 19.83 ± 3.97 , TM : 22.21 ±5.59 , MT : 26 , 59 ± 5.79 . The activation mode GFS was statistically higher than the 11 GFC (p = 0.036). And the apical obtained resistance values statistically superior compared to other union -thirds (p < 0.001). It can be concluded that the bond strength was significantly affected by the technique of photoactivation and the root region, and that the degree of conversion was not affected either by photoactivation technique nor the root region. O propósito deste estudo foi avaliar a influência de duas técnicas de fotopolimerização no grau de conversão (GC) de cimentos resinosos, bem como na retenção de pinos de fibra de vidro à dentina nos diferentes terços radiculares. Foram utilizados vinte pré-molares inferiores humanos extraídos seccionados transversalmente abaixo da a junção cemento-esmalte, cujas raízes foram tratadas endodonticamente. Após uma semana foi realizado o preparo padronizado dos condutos, e as raízes foram divididas aleatoriamente em dois grupos (n=10), de acordo com o modo de fotopolimerização do cimento resinoso dual (RelyX U200 – 3M ESPE): GFC - modo de ativação Contínuo e GFS - modo de ativação início Suave (Ramp). Os pinos intrarradiculares (White Post DC - FGM) foram cimentados de acordo com as recomendações do fabricante. Após o armazenamento em água destilada a 37°C por uma semana, as raízes foram seccionadas transversalmente em seis discos com 1 mm de espessura cada, e os terços coronário (TC), médio (TM) e apical (TA) do canal radicular foram identificados. Para avaliação do GC os espécimes foram submetidos à Espectroscopia Micro-Raman e para verificação da resistência de união (RU) ao teste de push out, realizado a uma velocidade de 0,5 mm/min. Os dados obtidos de GC e RU foram submetidos ao teste de análise de variância (ANOVA) 2 fatores, e ao pós teste de Tukey para comparação das médias (α = 0,05). Os valores médios de grau de conversão (%) e desvio padrão (DP) para cada grupo foram: GFC: 75,66±5,51, GFS: 77,38±5,66, em relação aos terços, GFC:TC: 73,87±5,50, TM: 74,59±4,86 e TA: 78,50±5,57, GFS: TC: 77,79±6,16, TM: 77,14±5,77 e TA: 77,21±5,79. Não houve diferença significativa entre as técnicas de fotoativação e nem entre os terços radiculares. Para resistência de união (MPa) os valores médios e desvio padrão (DP) foram: GFC: 18,46±6,23, GFS: 22,88±5,76, em relação aos terços, GFC: TC: 14,32±3,40, TM: 15,75±3,20, TA: 25,30±4,89, GFS:TC: 19,83±3,97, TM: 22,21±5,59, TA: 26,59±5,79. O modo de ativação GFS foi 9 estatisticamente superior em relação ao GFC (p=0,036). E o terço apical obteve valores de resistência de união estatisticamente superiores em relação ao outros terços (p
- Published
- 2015
16. EFEITO DA APLICAÇÃO SÔNICA DE SISTEMAS ADESIVOS NA ADESÃO DE PINOS DE FIBRA DE VIDRO NO CANAL RADICULAR
- Author
-
Sánchez, Johanna Lizbeth Cuadros, Loguércio, Alessandro Dourado, Sousa Neto, Manoel Damião, and Calixto, Abraham Lincoln
- Subjects
bond strength ,grau de conversão ,degree of conversion ,CIENCIAS DA SAUDE::ODONTOLOGIA [CNPQ] ,root dentin ,fiber posts ,pinos de fibra ,aplicação vibratória ,nanoinfiltração ,Pus-out ,Push-out ,sonic application ,dentina radicular ,resistência de uniao ,nanolake - Abstract
Made available in DSpace on 2017-07-24T19:22:33Z (GMT). No. of bitstreams: 1 Johanna Lizbeth Cuadros Sanchez.pdf: 3888267 bytes, checksum: abbdebf22c3a3a8b49c91f6bc734b34d (MD5) Previous issue date: 2014-02-26 Coordenação de Aperfeiçoamento de Pessoal de Nível Superior Abstract: Luting of posts inside the root canal is still a challenge because of the difficult to bonding mainly in the apical third. The aim of this study was evaluate the influence of the application of 3 simplified total-etch adhesive systems (Adper Single Bond 2 Ambar, and XP-Bond+self-cure activator) under manual mode or sonic vibration on the push-out bond strength (POBS), silver nitrate uptake (SNU) and in situ degree of conversion (ISDC) associated to resin cement when used for luted posts. Methods: The roots of 66 human premolars were prepared and divided into six groups (n=11), according to the following combination: adhesive and application mode. The posts were cemented in accordance with the manufacturer’s instructions of each cementation system. After water storage, the roots were sectioned transversely into six slabs and it were tested in POBS (0.5mm/min). Two roots for group were data were immersed in 50% silver nitrate, photo-developed and analyzed by SEM to measure the SNU. Two roots for group were evaluated by micro-Raman spectroscopy to measure ISDC. The data were analyzed by 3-way repeated measures ANOVA and Tukey's tests (5%). Results: When sonic application was performed, usually there are a significantly increasing on the POBS (MPa) (35% and 37% respectively) and ISDC (%) (14% and 38% respectively in the medium and apical thirds) and decreasing of SNU (%) for all groups mainly in the medium (64% decreasing) and apical (84%) thirds when compared with manually application (P < 0.05). Resumo: A cimentação de pinos dentro do canal radicular ainda é um desafio por causa das dificuldades relativas à adesão, principalmente no terço apical. O objetivo deste estudo foi avaliar a influência da aplicação de três sistemas adesivos convencionais simplificados (Adper Single Bond 2, Ambar e XP-Bond + self cure ativator) manualmente ou através de um dispositivo sônico vibratório na resistência de união por push-out (RU), na infiltração de nitrato de prata (NI) e no grau de conversão in situ (GC) associado ao cimento resinoso de cada fabricante, quando utilizado para cimentação de pinos. Métodos: As raízes de 66 pré-molares humanos foram preparadas e divididas em seis grupos (n = 11), de acordo com a seguinte combinação: adesivo/cimento e modo de aplicação. Os pinos foram cimentados de acordo com as instruções do fabricante de cada sistema de cimentação apenas variando o modo de aplicação. Depois do armazenamento em água, as raízes foram seccionadas transversalmente em seis fatias e foram testados em RU (0,5 mm/min). Duas raízes por grupo foram imersas em 50% de nitrato de prata, e após revelação, foram analisadas por MEV para medir a NI. Duas raízes por grupo foram avaliadas por espectroscopia de micro-Raman para medir GC. Os dados foram analisados por análise de variância de 3 fatores de medidas repetidas (terço radicular) e teste de Tukey (5%). Resultados: Quando a aplicação sônica vibratória foi utilizada, em geral, se observou um aumento significativo na RU (MPa) (35% e 37% respectivamente) e GC (%) (14% e 38% respectivamente nos terços médio e apical) e diminuição da NI (%) para todos os grupos, principalmente nos terços médio (redução de 64%) e apicais (84%) quando comparada com a aplicação manual (p
- Published
- 2014
17. Effects of energy density of light-activation of adhesive systems on bonding fiber posts to root canals
- Author
-
Szesz, Anna Luiza, Loguércio, Alessandro Dourado, Arrais, Cesar Augusto Galvão, and Silva, André Luis Faria e
- Subjects
bond strength ,nanoleakage ,dentina radicular ,grau de conversão ,degree of conversion ,CIENCIAS DA SAUDE::ODONTOLOGIA [CNPQ] ,resistência de união ,fiber posts ,root dentin ,energy density ,densidade de energia ,nanoinfiltração ,pino de fibra de vidro - Abstract
Made available in DSpace on 2017-07-24T19:22:35Z (GMT). No. of bitstreams: 1 ANNA LUIZA SZESZ.pdf: 3989892 bytes, checksum: 237bfbd8af89362f6139a3c445f884d8 (MD5) Previous issue date: 2014-02-25 This study evaluated, the intensity of light transmitted through a translucent fiber post ( Whitepost DC n° 2) using an experimental system and the effect of different densities of light energy in adhesive properties: degree of conversion within the hybrid layer (DC), nanoleakage (NL) and bond strength (μTBS) of two adhesive systems to dentin (Ambar [AM] and Excite DSC [EX]). The roots of 72 human premolars were prepared endodontically and divided into groups (n=6) according to the combination of factors: adhesive system (AM and EX) and energy density (16, 48 and 288 J/cm²). After cementing fiber post the roots with fiber post were subjected to μTBS (push-out) (n = 7) in a universal testing machine (0.5 mm/min). DC analysis (%) in situ (n = 2) was made by micro -Raman spectroscopy and NL was evaluated by SEM after immersing the samples in 50% silver nitrate (n=3). Data from the μTBS, NL, and DC of each adhesive were analyzed by 3-way repeated measures ANOVA (adhesive vs. Energy density vs. root third) and Tukey test (α = 0.05) . To measure the intensity of light transmitted through the post, the measuring device consisted of a light beam pulsed laser focusing perpendicular to the bottom surface of the post, and in the direction parallel to the axis of the post detector capable of measuring the scattered light at the post. To simulate the variation of light intensity, filters were used in this system with optical density varying the light intensity of 100, 25 and 10%. The results of μTBS (MPa) showed a significant difference for the middle and apical (p 0.05), in general, none of the tests results showed a significant difference when the cervical third was evaluated . Regarding the results of the intensity of light scattered by the post, light intensity reduced to 45,5% in the cervical region, to 14,2% and 5,3% in the middle and apical thirds, respectively. As for simulating the variation of light intensity, it was observed that the increase of the intensity of light incident on the base of the cervical post provides a gain of intensity of light reaching the apical level. Este estudo avaliou, através de um sistema experimental, a intensidade de luz transmitida por um pino de fibra translúcido (Whitepost DC n°2) e o efeito de diferentes densidades de energia da luz nas propriedades adesivas: grau de conversão no interior da camada híbrida (GC), nanoinfiltração (NI) e resistência de união (RU) à dentina de dois sistemas adesivos (Ambar [AM] e Excite DSC [EX]). As raízes de 72 pré-molares humanos foram preparadas endodonticamente e divididas em grupos (n=6) de acordo com a combinação dos principais fatores: sistema adesivo (AM e EX), e densidade de energia (16, 48 e 288 J/cm²). Após cimentação dos pinos de fibra, foi testado a RU (push-out) (n=7) em uma máquina de ensaios universal (0,5 mm/min). A análise do GC (%) in situ (n=2) foi feita através da espectroscopia micro-Raman e a NI foi avaliada por MEV após a imersão das amostras em 50% em nitrato de prata (n=3). Os dados de RU, GC e NI de cada adesivo foram analisados por ANOVA de 3 fatores de medidas repetidas (adesivo vs. densidade de energia vs. terço radicular) e teste de Tukey (α = 0,05). Para mensuração da intensidade de luz transmitida pelo pino, o sistema era constituído por um feixe de luz laser pulsado incidindo perpendicularmente a superfície da base do pino, e na direção paralela ao eixo do pino um detector capaz de mensurar a luz espalhada no pino. Para simular a variação da intensidade de luz foram utilizados junto a esse sistema filtros de densidade óptica, variando a intensidade de luz em 100, 25 e 10%. Os resultados de RU (MPa) demonstraram diferença significativa para os terços médio e apical (p < 0,05) quando houve aumento da densidade de energia de 16 para 48 e 288 J/cm² respectivamente. O GC (%) aumentou significativamente na densidade de 288 J/cm² nos terços médio e apical quando comparado os mesmos terços com a menor densidade de energia 16 J/cm² (p 0,05). Em geral, nenhum dos testes apresentaram resultados com diferença significativa quando o terço cervical foi avaliado. Em relação aos resultados da intensidade da luz espalhada pelo pino observamos que na região cervical a intensidade de luz reduz para 45,5 % no terço médio para 14,2 % e para apical 5,3%. Quanto a simulação da variação da intensidade da luz, foi possível observar que o aumento da intensidade de luz incidente na base cervical do pino proporciona um ganho de intensidade de luz que chega ao nível apical.
- Published
- 2014
18. Study 'in situ' ofthe polymerization shrinkage-strain and degree of conversion of resin cements used for luting intracanal fiber posts
- Author
-
Mora, Camilo Andrés Pulido, Gomes, Osnara Maria Mongruel, Franco, Ana Paula Gebert, and Arrais, Cesar Augusto Galvão
- Subjects
polymerization ,degree of conversion ,CIENCIAS DA SAUDE::ODONTOLOGIA [CNPQ] ,resin ,grau de conversão, cimentos resinosos ,Fiber Bragg Gratings ,polimerização ,Fibras de Bragg - Abstract
Made available in DSpace on 2017-07-24T19:22:01Z (GMT). No. of bitstreams: 1 Camilo Andres P Mora.pdf: 2179325 bytes, checksum: 956a5f1d8568fa3876b0879ad21942c4 (MD5) Previous issue date: 2014-02-17 Coordenação de Aperfeiçoamento de Pessoal de Nível Superior The aim of this study was to investigate the shrinkage-strainand degree of conversion inside the rootcanal"in situ"of resin cements used to lute fiber posts (Whitepost DC, FG). Thirty maxillary canines with similar root length average were selected (14 mm ± 1 mm). Each root canal was treated with crown-down technique and filled with gutta-percha, leaving 4 mm of apical seal.One week later, the roots were prepared following fiber post system manufacturer’s instructions. For the cementation, teeth were randomly divided into 2 groups (n = 15) according to the resin cement used: Group 1: dual-cured resin cement RelyX™ ARC – Adper Scotchbond™ Multipurpose Plus Adhesive (3M/ESPE) and Group 2: dual-cured resin cement RelyX™ U200 (3M/ESPE). Two fiber optic sensors with recorded Bragg gratings were attached to the coronal section (not in contact with the root) of each post before inserting the resin cement inside the root canal. These sensors measured the deformations of the cement over the coronal and apical section of the root (μe). Once measured, the specimens were sectionated in order to obtain slides on its cervical and apical sections. The degree of conversion of the cements on each third was analyzed by μ-Raman micro-spectroscopy. The data were statitsticallyanalyzed by two-way ANOVA (p = 0.05). The dual-curedconventional resin cement tested in this study showed the highest values of shrinkage-strain and degree of conversion; cervical region showed higher values than apical region in both of resin cements. O objetivo deste estudo foi conhecer o comportamento e a magnitude das deformações que ocorrem durante a polimerização “in loco” no interior do canal radicular, em cimentos resinosos durante a fixação de pinos de fibra de vidro Whitepost DC (FGM) e verificar o grau de conversão dos mesmos. Foram selecionados 30 caninos superiores (n=10) com comprimento radicular médio de 14 mm medidos da junção cemento-esmalte (JCE). Os canais foram tratados endodonticamente ea guta-percha foi removida deixando 4 mm do selamento apical. Após uma semana os canais foram preparados. Para a cimentação, os dentes foram divididos aleatoriamente em 2 grupos, segundo o cimento resinoso utilizado: Grupo ARC: cimento resinoso dual RelyX™ ARC – Adesivo Adper Scotchbond™ Multipurpose Plus (3M/ESPE) e Grupo U200: cimento resinoso dual RelyX™ U200 (3M/ESPE). Antes da inserção do cimento resinoso no interior do canal radicular foram posicionados no pino dois sensores de fibra óptica com redes de Bragg gravadas e colados na região que não entrou em contato com as paredes do canal; um na posição mais apical e outro na mais cervical do pino. Os sensores realizaram a mensuração das deformações do cimento em uma porção coronária e apical do canal radicular, para se obter valores em micro-strain (μe). Logo depois, os espécimes foram cortados em fatias para mensuração do grau de conversão dos cimentos, nos terços apical e cervical por meio da espectroscopia μ-Raman. Os dados obtidos foram analisados estatisticamente por meio do teste ANOVA de dois fatores (p=0,05).Os sensores de fibra óptica com redes de Bragg mostraram-se eficientes na mensuração de contração de polimerização de cimentos resinosos. O cimento resinoso convencional testado no estudoapresentou maiores valores de contração de polimerização e grau de conversão, quando comparado com o cimento resinoso autoadesivo. O terço cervical apresentou maiores valores de contração de polimerização e grau de conversão, quando comparado com o terço apical independentedo tipo de cimento.
- Published
- 2014
19. Effect of different universal adhesive application protocols on the properties and longevity of bond to dentin
- Author
-
Pérez, Miguel Angel Muñoz, Campanha, Nara Hellen, Loguércio, Alessandro Dourado, Reis, Alessandra, Arrais, Cesar Augusto Galvão, Yamauti, Monica, and Francci, Carlos
- Subjects
bond strength ,sistemas adesivos ,nanoleakage ,grau de conversão ,degree of conversion ,CIENCIAS DA SAUDE::ODONTOLOGIA [CNPQ] ,dentin ,self-etch ,nanoinfiltração ,dentina ,adesivos convencionais ,etch-and-rinse ,adesivos autocondicionantes ,resistência de união ,adhesive systems - Abstract
Made available in DSpace on 2017-07-24T19:22:33Z (GMT). No. of bitstreams: 1 Tese Miguel Munoz Doutorado Odontologia 2014.pdf: 3888005 bytes, checksum: 9a25e76295a44d9cdb11d6afb38c9041 (MD5) Previous issue date: 2014-02-07 Fundação Araucária de Apoio ao Desenvolvimento Científico e Tecnológico do Paraná The aim of the present study was to make an in vitro evaluation of the properties and stability of the bond to dentin of new universal adhesive systems applied according to the etch-and-rinse (ER) and self-etching (SE) adhesive strategies. The specific objectives for each of the three studies were: To evaluate the microtensile bond strength (RU), nanoleakage (NI) and degree of conversion (DC) in the time intervals of 24 h (Experiment 1) and six months (Experiment 2) of the universal adhesive systems applied in accordance with the manufacturers’ recommendations for strategies ER and SE; and the effect of an additional hydrophobic layer (Experiment 3, in the immediate time interval) on these same properties. The occlusal surfaces of 140 third molars were flattened until dentin was obtained, and then the teeth were randomly allocated to 28 groups (n=5). In Experiments 1 and 2, 40 teeth were divided into eight groups according to the adhesive used (Peak Universal [Pk], Scotchbond Universal [Sc], Allbond Universal [Al]) and adhesive strategy (ER and SE), with the ER adhesive system Adper Single Bond 2 (SB) and self-etching Clearfil SE Bond (CSE) used as controls. For Experiment 3, 60 teeth were divided into 12 groups according to the adhesive (Sc, Al, G-Bond Plus [Gbp]), adhesive strategy (ER and SE) and with or without hydrophobic layer (Heliobond, HE). After application of the variables adhesives and restorative procedure, the teeth were stored in distilled water (37oC/24 h) and cut to obtain dentin-resin sticks (0.8 mm2 cross-section) which were submitted to the RU and NI tests in the following time intervals: immediate (Experiments 1 and 3) and six months (Experiment 2); and analysis of DC in the immediate time interval. The data of Experiment 1 were submitted to one-way analysis of variance (Adhesive Strategy) and those of Experiments 2 and 3, to twoway analysis of variance (Adhesive strategy vs. Time intervals; and Adhesive strategy vs. Hydrophobic layer) respectively. The analyses were complemented by the Tukey Test (α=0.05). The RU results obtained in Experiment 1 demonstrated that only PkEr and PkSe were similar to the respective control groups (p>0.05); that the other universal materials resulted in lower RU means than those of their controls ER and SE (p0,05), que os outros materiais universais resultaram em médias de RU inferiores aos seus controles CON e AC (p
- Published
- 2014
20. Influence of physicochemical properties of resin materials and insertion technique on marginal adaptation of class II restorations
- Author
-
Gonçalves, Silvia Maria Ribeiro de Alencar, Sampaio Filho, Hélio Rodrigues, Silva, Eduardo Moreira da, Dias, Katia Regina Hostilio Cervantes, Miranda, Mauro Sayão de, Mello, José Benedicto de, Barceleiro, Marcos de Oliveira, and Dias, Angela Alexandre Meira
- Subjects
Grau de conversão ,Fenda marginal ,Composite resin ,Degree of conversion ,Resina composta ,CIENCIAS DA SAUDE::ODONTOLOGIA [CNPQ] ,Contraction stress ,Tensão de contração ,Módulo de elasticidade ,Elastic modulus ,Marginal gap - Abstract
Submitted by Boris Flegr (boris@uerj.br) on 2021-01-07T14:56:35Z No. of bitstreams: 1 tese_crip.pdf: 2764571 bytes, checksum: ede5721f74a4df0c464d90be4e52eaea (MD5) Made available in DSpace on 2021-01-07T14:56:35Z (GMT). No. of bitstreams: 1 tese_crip.pdf: 2764571 bytes, checksum: ede5721f74a4df0c464d90be4e52eaea (MD5) Previous issue date: 2013-02-25 The shrinkage of composite resin polymerization is an undesirable characteristic that compromises the integrity of the tooth / restoration interface. The aim of this study was to evaluate in vitro the influence of different materials used in composite resin class II restorations in terms of contraction stress, flexural strength, degree of conversion and marginal gap formation. Class II preparation were performed with 4x4x2mm dimensions in third molars freshly extracted for the evaliation of marginal gap formation. The cavities were filled with Riva Light Cure (SDI) glass ionomer cement (CIV), SureFil ® SDR (Dentsply) low shrinkage resin (SDR), Filtek Z350Flow (3M/ESPE) flowable composite (Z350F) and Filtek P90 (3M/ESPE) composite resin (P90). The restorations (n = 3) were evaluated with magnifying stereoscopic. The flexural strength was assessed by means of three point bending test. For this test ten specimens (n = 10) of each material were made, each with 10x2x1mm dimensions. For the shrinkage stress test polymethacrylate cylinders with 5 mm in diameter and 13 or 28mm in length were used. Bats were attached to the EMIC with a 2mm space between them, where the materials were inserted. The test were repeated five times for each group (n = 5) and the contraction stress was measured for up to 10 minutes after initiation of photopolymerization. The Degree of Conversion (DC) was determined by Fourier transform infrared (FTIR). The results were statistically analyzed by the variance analysis (ANOVA) and Tukey test (p SDR = P90. Contraction stress: Z350F > SDR> CIV = P90. Flexural strength: P90 > SDR = Z350F > CIV. Elasticity Modulus: P90 > CIV = SDR = Z350F. DC: Z350F = SDR > P90 > CIV. Conclusion: There is a correlation between formation of marginal gap and physicochemical properties of the materials tested whereas low shrinkage resins provided better marginal adaptation; correlation exists between flexural strength, elastic modulus, shrinkage stress and material composition, since better results were obtained from composites with larger quantity of load; higher conversion degree did not represent better mechanical properties. A contração de polimerização das resinas compostas é uma característica indesejável que compromete a integridade da interface dente/restauração. O objetivo deste estudo foi avaliar in vitro a influência de diferentes materiais usados em restaurações classe II de resina composta, quanto ao grau de conversão, tensão de contração, resistência a flexão, módulo de elasticidade e formação de fenda marginal. Foram realizados preparos classe II com dimensões de 4x4x2mm em terceiros molares recém-extraídos para a avaliação da formação de fenda marginal. As cavidades foram niveladas com cimento de ionômero de vidro Riva Light Cure (SDI) (CIV), resina de baixa contração SureFil®SDR (Dentsply) (SDR), resina flow Filtek Z350Flow (3M/ESPE) (Z350F) e resina composta Filtek P90 (3M/ESPE) (P90). As restaurações (n=3) foram avaliadas com lupa estereoscópica. A resistência a flexão foi avaliada por meio de ensaio de flexão em três pontos. Para este ensaio foram confeccionados dez corpos de prova (n=10) de cada material com dimensões de 10x2x1mm. Para o teste de tensão de contração foram utilizados cilindros de polimetacrilato com 5 mm de diâmetro e 13 ou 28mm de comprimento. Os bastões foram fixados na EMIC com um espaço de 2mm entre eles, onde os materiais foram inseridos. Foram realizadas cinco repetições para cada grupo (n=5) e a tensão proveniente da contração foi medida por até 10 minutos após o início da fotopolimerização. O Grau de Conversão (GC) foi determinado por espectroscopia no infravermelho com transformada de Fourier (FTIR). Os resultados foram tratados estatisticamente por análise de variância (ANOVA) e Teste de Tukey (p SDR = P90. Tensão de contração: Z350F > SDR > CIV = P90. Resistência a flexão: P90 > SDR = Z350F > CIV. Módulo de Elasticidade: P90 > CIV = SDR = Z350F. GC: Z350F = SDR > P90 > CIV. Conclusões: existe correlação entre a formação de fenda marginal e as propriedades físico químicas dos materiais testados, sendo as resinas de baixa contração que proporcionaram melhor adaptação marginal; existe correlação entre resistência a flexão, módulo de elasticidade, tensão de contração e a composição dos materiais, já que os compósitos com melhores resultados foram os que apresentaram os maiores percentuais de carga, no entanto, maior grau de conversão não representou melhores propriedades mecânicas.
- Published
- 2013
21. Assessment of solvent evaporation of contemporary adhesives system
- Author
-
Werle, Stefanie Bressan, Rocha, Rachel de Oliveira, Silveira, Bruno Lopes da, and Cesar, Paulo Francisco
- Subjects
Bond strength ,Grau de conversão ,Degree of conversion ,Sistema adesivo ,CIENCIAS DA SAUDE::ODONTOLOGIA [CNPQ] ,Solvent ,Solvente ,Adhesive system ,Resistência de união - Abstract
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior Objectives: The aim of this study was to evaluate the effect of air-drying time on degree of evaporation of solvent (DE), microtensile resin-dentin bond strength (μTBS) and degree of conversion (DC) of adhesive systems. Methods: Four two-steps etch-and-rinse (Adper Single Bond 2, XP Bond, Prime & Bond 2.1 and Opti Bond Solo) and one one-step self-etch (Adper Easy One) were tested. The DE was measured gravimetrically (n=6) after 3, 5, 10, 20, 30 and 60 seconds by air-drying. For μTBS flat dentin surfaces were obtained from fifty caries-free extracted molars (n=5). The adhesive systems were applied to dentin surfaces according to the manufacturer s instructions and subsequently air-drying for the time proposed by manufacturer (A) or for prolonged time (B), corresponding to maximum DE in the times evaluated. A composite resin was used for coronal build-up. After 24h water storage at 37ºC, the specimens were sectioned in x and y directions to obtain bonded sticks (0.9 mm2) which were immediately subjected to μTBS (1mm/min). The DC (n=3) was calculated by Fourier-transform infrared spectroscopy with attenuated total reflectance considering air-drying times A and B. The data of DE were statistically analyzed by ANOVA and Tukey´s test, μTBS and DC were analyzed by T-Test (α = 0.05). Results: The prolonged time (B) increased the DE for all materials compared to manufacturer´s times, however improved μTBS only for XP Bond and Adper Easy One. DC was not affected by evaluated air-drying times. There was no significant correlation between DC and μTBS. Conclusion: The evaporation of solvent from adhesive systems is affected by air-drying. The effect of air-drying time seems be material-dependent on parameters evaluated. Changes in protocols of use may be necessary to obtain better properties. Objetivos: Avaliar o efeito de diferentes protocolos de aplicação de jato de ar no grau de evaporação do solvente (GE), resistência de união à dentina (RU) e grau de conversão (GC) de sistemas adesivos. Métodos: Quatro sistemas adesivos de dois passos com condicionamento ácido prévio (Adper Single Bond 2, XP Bond, Prime & Bond 2.1 e Opti Bond Solo) e um autocondicionante de passo único (Adper Easy One) foram testados. O GE foi mensurado gravimetricamente (n=6) após a aplicação de jato de ar durante 3, 5, 10, 20, 30 e 60 segundos. A RU à dentina foi mensurada através do teste de microtração. Para isso, cinquenta molares humanos hígidos (n=5) tiveram o esmalte e dentina superficial removidos. Os sistemas adesivos foram aplicados de acordo com as instruções dos fabricantes na superfície dentinária e subsequentemente foi aplicado jato de ar durante o tempo proposto pelo fabricante (A) ou por tempo prolongado (B), o qual resultou em evaporação máxima nos tempos considerados na avaliação do GE. Após a confecção de blocos de resina composta e armazenamento em água à 37ºC, por 24 horas, os espécimes foram seccionados em dois eixos a fim de obterem-se espécimes com área de secção transversal de aproximadamente 0,9 mm2. Os espécimes foram submetidos ao teste de microtração com velocidade de 1mm/min. O GC (n=3) foi analisado por espectroscopia de infravermelho transformada de Fourier (FTIR) considerando os tempos A e B. Os dados do GE foram submetidos à análise de variância de um fator e teste de Tukey. Os dados de RU e GC foram submetidos ao teste t de Student pareado. Todas as análises foram realizadas considerando o nível de significância de 5%. Resultados: A aplicação de jato de ar por tempo prolongado (B) aumentou o GE para todos os materiais em comparação ao tempo proposto pelo fabricante. Contudo, maiores valores de RU foram obtidos somente para os sistemas XP Bond e Adper Easy One. O GC não foi afetado pelos tempos de aplicação de jato de ar avaliados. Não houve correlação significante entre GC e RU. Conclusão: A evaporação do solvente dos sistemas adesivos testados é modulada pelo tempo de aplicação de jato de ar. A influência do tempo de aplicação do jato de ar nos parâmetros testados parece ser material dependente. Mudanças no protocolo de aplicação jato de ar podem ser necessárias a fim de se obterem as melhores propriedades dos sistemas adesivos.
- Published
- 2012
22. Biocompatibility of adhesive systems free experimental self-etching HEMA
- Author
-
Barbosa, Marília Oliveira, CPF:62047094020, Carvalho, Rodrigo Varella de, and Silva, Adriana Fernandes da
- Subjects
Monomer ,Grau de conversão ,Degree of conversion ,Monômero ,CIENCIAS DA SAUDE::ODONTOLOGIA [CNPQ] ,Sistemas adesivos ,Teste de citotoxicidade ,HEMA ,Adhesive systems ,Cytotoxicity test - Abstract
Made available in DSpace on 2014-08-20T14:30:13Z (GMT). No. of bitstreams: 1 Dissertacao_Marilia_Oliveira_Barbosa.pdf: 1068284 bytes, checksum: 523346df7ee3bd1a1ce4c3ee23aff3e8 (MD5) Previous issue date: 2011-03-31 HEMA is a monomer widely used in the adhesive systems, although the biologic performance has been found as negative it has been tried to solve this problem by testing new monomers with lower citotoxic potential. We analyzed the biocompatibility of five experimental dimethacrylate monomers: Bis-EMA 10, Bis- EMA 30, PEG 400, PEG 400 UDMA, PEG 1000. First, it was made an in vitro test using 3T3 mouse fibroblast cell culture. So, the cytotoxic test was made using primers at 20% and 2%. The dilutions were maintained in contact with the cells for a period of 24h and after the survival these cells was verified photometrically using MTT assay. After it was performed cytotoxic test with the resin bonds as follows: hese monomers were polymerized and leaving in immersion in DMEM for 24h and later the eluate obtained was inserted on the 3T3 cell for 24h. The statistical analysis was performed by Kruskal wallis method, followed by a multiple-comparison Dunn´s test (p
- Published
- 2011
23. Diphenyliodonium hexafluorphosphate effect on the radical polymerization of methacrylates
- Author
-
Ogliari, Fabrício Aulo, CPF:91234034034, Petzhold, Cesar Liberato, and Piva, Evandro
- Subjects
Iodônio ,Grau de conversão ,Iodonium ,Degree of conversion ,CIENCIAS DA SAUDE::ODONTOLOGIA [CNPQ] ,Polimerização ,Polymerization - Abstract
Made available in DSpace on 2014-08-20T14:30:12Z (GMT). No. of bitstreams: 1 Tese_Fabricio_Aulo_Ogliari.pdf: 990670 bytes, checksum: 3309e79bda50d0506e497074067ddfca (MD5) Previous issue date: 2009-07-10 The present investigation evaluated the effect of the diphenyliodonium hexafluorphosphate (DPIHFP) on the radical polymerization of methacrylates. Rate of polymerization from binary and ternary photoinitiation systems, performance of such systems in the presence of solvent and its effects on the bonding strength to bovine dentin were investigated. As a model adhesive resin, a blend of Bis-GMA, TEGDMA and HEMA (50/25/25 %wt) was prepared. Real-time degree of conversion was performed in a Fourier transform infrared spectrometer. To assess the photoinitiator system efficiency in a dental adhesive composition, the adhesion between the model resin and bovine dentin was investigated using microtensile bond strength(μTBS). When CQ was used as photo-initiator, a slow polymerization reaction was observed. The addition of a second component (onium salt or amine) increases the polymerization rate and conversion independent on the co-initiator concentration. Ternary photo-initiator system showed an improvement on the polymerization rate of the dental adhesive model resin leading to high conversion in short photo-activation time.The addition of a solvent to the monomer blends decreased the polymerization kinetics, directly affecting the rate of polymerization, delaying vitrification, and attenuating the Trommsdorf effect. The introduction of DPIHFP displayed a strong increase in reaction kinetics, reducing the solvent inhibition effect. After one year of storage, the μTBS values of the group CQ+EDAB+DPIHFP showed significantly higher bond strength(p
- Published
- 2009
24. Caracterização de materiais experimentais e comerciais para reembasamento imediato por meio de análise de propriedades físico-químicas e mecânicas
- Author
-
Reis, José Mauricio Dos Santos Nunes, Universidade Estadual Paulista (Unesp), and Vergani, Carlos Eduardo [UNESP]
- Subjects
Resinas acrilicas ,Grau de conversão ,Acrylic resins ,Degree of conversion ,Solubility ,Reembasadores de dentadura ,Resistência ao cisalhamento ,Solubilidade ,Denture rebasing ,Denture liners - Abstract
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-03Bitstream added on 2014-06-13T19:44:47Z : No. of bitstreams: 1 reis_jmsn_dr_arafo.pdf: 1310753 bytes, checksum: 17bd719b0c46c00b10cbd2db022db42a (MD5) Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) Este estudo avaliou o comportamento exotérmico de 5 resinas rígidas para reembasamento imediato, duas experimentais (E1 e E2) à base de agentes de ligação cruzada (etileno glicol dimetacrilato e 1,4-butanediol dimetacrilato) e três comerciais (Kooliner-K, New Truliner-NT, Tokuyama Rebase II-TR II), bem como o grau de conversão (GC), a sorção (Sor) e a solubilidade (Sol) em água, a contração linear de polimerização (CLP), as propriedades viscoelásticas e a resistência à flexão desses materiais e de uma resina para base de prótese (Lucitone 550-L). Foi avaliada, ainda, a resistência de união (RU) entre os reembasadores e a resina de base. O comportamento exotérmico foi avaliado (n=4) com termopar tipo K inserido no interior das resinas, em matriz circular (60 x 2,0 mm), e mantido até a polimerização. O GC (%) foi avaliado (n=5) por espectroscopia de infravermelho por transformadas de Fourier (32 leituras; resolução 4,0 cm-1). A Sor e a Sol (μg/mm3) foram mensuradas (n=5) seguindo as recomendações da ISO 1567. A CLP (%) foi avaliada (n=10), em projetor de perfil (Nikon 6C), em corpos-de-prova circulares (50 x 0,5 mm). Para avaliar as propriedades viscoelásticas, corpos-de-prova (40 x 10 x 3,3 mm) foram submetidos (n=2) à análise térmica dinâmico-mecânica (DMTA) em diferentes intervalos de temperatura (ciclos). O módulo de armazenamento (E’) e o amortecimento mecânico (tan δ) a 37ºC foram registrados durante o primeiro e último ciclo da DMTA. A temperatura de transição vítrea (Tg) foi mensurada somente no último ciclo da DMTA. Os ensaios mecânicos de flexão (0,5 mm/min) foram realizados (n=10) em corpos-de-prova (64 x 10 x 3,3 mm) intactos ou reembasados e a resistência (MPa) calculada na tensão máxima (RFM) e no limite de proporcionalidade (RFLP). Para avaliar a RU (MPa) entre os materiais, 60 cilindros (20 x 20 mm) da resina L foram processados... This study evaluated the exothermic behavior, degree of conversion (DC), water sorption (WSor), water solubility (WSol), linear polymerization shrinkage (LPS), viscoelastic properties and flexural strength of 5 hard chairside reline resins, two experimental (E1 and E2) based on crosslinking agents (ethylene glycol dimethacrylate and 1,4-butanediol dimethacrylate) and three commercially available (Kooliner-K, New Truliner-NT and Tokuyama Rebase II-TR II), and one heat-polymerized denture base resin (Lucitone 550-L). The shear bond strength (SBS) between the denture base resin and the reline materials was also evaluated. The exothermic behavior of circular specimens (60 x 2.0 mm) during polymerization was assessed (n=4) using a type K thermocouple. The DC (%) was measured (n=5) by Fourier Transformed infrared-attenuated total reflectance (FTIR-ATR) spectroscopy (32 scans; resolution of 4.0 cm-1). WSor and Wsol (μg/mm3) were determined (n=5) according to the recommendation stated in ISO 1567. The LPS (%) was measured (n=10) in circular specimens (50 x 0.5 mm) using a perfilometer (Nikon 6C). The viscoelastic properties of the specimens (40 x 10 x 3.3 mm) were evaluated (n=2) by dynamical-mechanical thermal analysis (DMTA) under different temperature ranges (runs). Values of storage modulus (E’) and loss tangent (tan δ) at 37ºC were obtained from the first and last runs. The glass transition temperature (Tg) was only measured from the last run. Ultimate flexural strength (UFS - MPa) and flexural strength at the proportional limit (FSPL - MPa) were determined (n=10) by three-point test (0.5 mm/min) using intact and relined specimens (64 x 10 x 3.3 mm). To evaluate the SBS between the materials, 60 cylinders (20 x 20 mm) of the denture base resin L were processed, relined (3.5 x 5.0 mm) and submitted to shear testing (0.5 mm/min). Data were analyzed by ANOVA and Tukey... (Complete abstract click electronic access below)
- Published
- 2009
25. Profundidade de polimerização de cimentos resinosos utilizados na cimentação de pinos translúcidos e sua influência sobre a resistência adesiva antes e após ciclagem mecânica
- Author
-
Galhano, Graziela Ávila Prado [UNESP], Universidade Estadual Paulista (Unesp), and Bottino, Marco Antônio [UNESP]
- Subjects
Degree of conversion ,Materiais dentários ,Pinos dentários ,Cimentos de resina - Abstract
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-05-16Bitstream added on 2014-06-13T18:46:00Z : No. of bitstreams: 1 galhano_gap_dr_sjc.pdf: 385997 bytes, checksum: e9e65faf9da79b458c552d9829193cca (MD5) Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) Este estudo teve com objetivo analisar a capacidade de um pino translúcido transmitir luz para o interior do canal radicular, bem como analisar o efeito desta polimerização na resistência mecânica e adesiva do conjunto pino, cimento, dente. Além disso, foi avaliada a resistência adesiva de diferentes tipos de cimentos resinosos. Foram utilizados 70 dentes humanos unirradiculares. O canal foi preparado com as fresas n°3 dos sistemas de pinos Light-Post (Bisco Inc, EUA). As raízes foram pintadas com esmalte preto para evitar a passagem de luz pela lateral do dente. Todos os dentes foram tratados com o sistema adesivo All Bond 2 (Bisco) e cimentados com três tipos de cimento formando os seguintes grupos: G1) Cimento Dual Duolink (Bisco) não fotopolimerizado, G2) Cimento Dual duolink fotopolimerizado, G3) Cimento Químico (C&B - Bisco) e G4) cimento fotopolimerizável (Illusion, Bisco). Cada grupo foi subdividido segundo a execução ou não de ciclagem mecânica. Em seguida, os dentes foram cortados perpendicular ao longo eixo do dente obtendo espécimes de 2mm de espessura. Cada secção era correspondente a uma região do dente (cervical, média, apical), possibilitando observar a polimerização do cimento nas diferentes profundidades da raiz realizando a analise Raman em três dentes de cada grupo. Em seguida, foi realizado o teste de push-out.Como resultado foi observado menor grau de conversão em direção apical para os cimentos foto-ativados, enquanto o cimento dual sem foto-ativaçao apresentou maiores valores. Para a resistência adesiva foi observada semelhança estatística inicial entre o cimento Duolink foto-ativado ou não, sendo que q ciclagem mecânica diminui consideravelmente a RA do Duolink quimicamente polimerizado. O cimento fotopolimerizável apresentou valores muito baixos de resistência adesiva e o cimento químico C&B apresentou os maiores valores antes e apos ciclagem mecânica. This study aimed to evaluate the light transmittance of a translucent post in the root canal, as well as the effects of light polymerization onto fatigue resistance and bond strengths at the post/cement/tooth joint. Moreover, the bond strengths obtained with different types of resin cement were determined. 70 human teeth were used. The root canals were prepared with Light Post drills (Bisco Inc, EUA) (size 3). Afterwards, the outer surface of each tooth was covered with black nail varnish to avoid passage of light through the root lateral walls. All teeth were treated with All Bond 2 (Bisco) bonding agent. They were divided into groups according to the resin cement: G1) non light-cured Duo-link dual-cure cement (Bisco), G2) light-cured Duo-link dual-cure cement, G3) C&B chemical-cure cement (Bisco) and G4) Illusion light-cure resin cement (Bisco). Each group was divided into subgroups, to designate the specimens subjected to mechanical cycling or not. Following that, the teeth were sectioned perpendicular to their long axis into 2mm sections. Each section corresponded to one of three study regions (cervical, middle and apical regions of the root canal preparation), allowing the determination of the degree of conversion at different levels of the root by using Raman spectroscopy in three teeth per group. Afterwards, the segments were subjected to Push-out bond strength test. The light-activated cements had the lowest degree of conversion towards the apical region whereas the dual-activated one presented the highest values. As for bond strength, the light- and non light-activated Duo-link groups were statistically similar in the beginning, but the mechanical cycling decreased the bond strength of the non light-activated group. The light-activated cement had the lowest bond strengths and the chemical cement (C&B) presented the highest bond strength values before and after mechanical cycling.
- Published
- 2008
26. Influence of polymerization mode and a simulated ceramic restoration on degree of conversion and surface hardness of a dual-cured self-adhesive resin cement
- Author
-
Matos, Irma Cunha, Miranda, Mauro Sayão de, Mendes, Luis Claudio, Sampaio Filho, Hélio Rodrigues, Mussel, Rogério Luiz de Oliveira, and Borges, Márcio Antônio Paraizo
- Subjects
Self-adhesive resin cement ,Grau de conversão ,Degree of conversion ,Cimento resinoso auto-adesivo ,Microhardness ,Materiais dentários ,CIENCIAS DA SAUDE::ODONTOLOGIA [CNPQ] ,Cimentos de resina ,Dureza superficial - Abstract
Submitted by Boris Flegr (boris@uerj.br) on 2021-01-07T15:05:11Z No. of bitstreams: 1 Irma Cunha Matos.pdf: 1528324 bytes, checksum: 63a13700093b2301ba9e77416af3bd5f (MD5) Made available in DSpace on 2021-01-07T15:05:11Z (GMT). No. of bitstreams: 1 Irma Cunha Matos.pdf: 1528324 bytes, checksum: 63a13700093b2301ba9e77416af3bd5f (MD5) Previous issue date: 2008-02-28 The aim of this study was to evaluate the degree of conversion (DC) and the microhardness of a self-adhesive resin cement under different activation protocols, immediately and after 24 hours of the beginning of the polymerization, and, defining cement regarding monomer composition, average diameter of the inorganic fillers and the percentage by weight of the organic and inorganic portions. Forty specimens (8 mm in diameter, 0.5 mm in height) were prepared. Half of them were used to determine DC and the other half were used on the microhardness test. The specimens were divided into four groups: GR1 direct photoactivation for 20s, GR2 photoactivation through 2mm porcelain disc for 20s, GR3 photoactivation through 2 mm porcelain disc for 40 s, and GR4 photoactivation was omitted and curing was reliant on the chemical reaction only. Vickers microhardness (HV) and DC, by FTIR-ATR, were determined immediately after photoactivation (GR1, GR2 e GR3) or after five minutes from the beginning of the polymerization (GR4). After dry storage in the dark, for 24 hours, the samples were submitted to the tests again. In order to define the studied cement, the Thermogravimetric method was applied, as well as the Infrared Spectometry, Nuclear Magnetic Ressonance Spectroscopy and Scanning Electron Microscope. Data were statistically analyzed by one-way ANOVA, t-Test and Bonferroni Test (P≤0,05) and the degree of conversion values obtained immediately after polymerization and after 24 hours were, respectively: GR1: 29.64% ± 4.05 / 32.58% ± 2.99; GR2: 27.07% ± 2.39 / 28.9%1 ± 3.9 / GR3: 28.18% ± 3.6 / 32.34% ± 4.04; GR4: 7.94% ± 2.4 / 20.38% ± 4.89. HV values obtained immediately after polymerization and after 24 hours were, respectively: GR1: 7.98HV ± 1.8 / 14.88HV ± 2.33; GR2: 4.84HV ± 0.13 / 9.06HV ± 1.63; GR3: 6.53HV ± 2.51 / 11.42HV ± 1.97. The low DC for GR4 do not permitted to quantify the initial HV value and after 24 hours this values was 10.65HV ± 0.92. The chemical curing mode showed DC and HV results for both period (initial and after 24 hours), statistically lower than the other groups where the photoactivation was used. The simulated ceramic restoration did not influence monomer conversion, however it negatively influence resin cement hardness. The exposure time did not influence resin cement hardness and monomer conversion. The inical DC and HV were significantly greater than after 24 hours, except for DC for initial period, when the photoactivation was realizded through a porcelain disc for 20s.There was a linear and positive correlation between degree of conversion and microhadness for the self-adhesive resin cement RelyX Unicem. Defining the cement: organic portion composed by a mixture of monomers. Bis-GMA is the main monomer. Presence of a dimethacrylate containing hydroxyl to connect to the phosphoric acid as a phosphate. Inorganic fillers raging between 0,4 to 11,2m. Powder is composed by 96% of inorganic particles. In liquid fraction, the organic portion corresponds to 84%. There were 16% of waste that did not burn due to nitrogen atmosphere. Este estudo objetivou analisar o grau de conversão (GC) e a microdureza de um cimento resinoso utilizando diferentes protocolos de ativação, e, caracterizar o cimento quanto à composição monomérica, diâmetro médio das partículas inorgânicas e porcentagem em peso das frações orgânica e inorgânica. Foram preparados quarenta espécimes (8mm de diâmetro, 0,5mm de espessura), sendo metade usada para a determinação do GC e a outra metade usada no teste de microdureza. Os espécimes foram divididos em quatro grupos: GR1 fotoativação realizada diretamente sobre o cimento por 20s, GR2 fotoativação através de um disco de porcelana com 2mm de espessura por 20s, GR3 fotoativação através de um disco de porcelana com 2mm de espessura por 40s, e GR4 fotoativação foi omitida e o material foi polimerizado exclusivamente por seus componentes químicos. A dureza Vickers (HV) e o GC, determinado através de FTIR-ATR, foram realizados imediatamente após a fotoativação (GR1, GR2 e GR3) ou cinco minutos após o início da polimerização (GR4). Após armazenagem em ambiente seco e escuro por 24h, os espécimes foram novamente submetidos aos testes de HV e GC. Para a caracterização do material avaliado, foram realizadas as análises: Termogravimétrica, Espectrometria no Infravermelho, Espectrometria de Ressonância Magnética Nuclear e Microscopia Eletrônica de Varredura. Os resultados foram analisados estatisticamente por ANOVA, teste t e teste de Bonferroni (P≤0,05). Os valores do GC nos períodos imediato e 24h foram, respectivamente: GR1: 29.64% ± 4.05 / 32.58% ± 2.99; GR2: 27.07% ± 2.39 / 28.9%1 ± 3.9 / GR3: 28.18% ± 3.6 / 32.34% ± 4.04; GR4: 7.94% ± 2.4 / 20.38% ± 4.89. Os valores de HV nos períodos imediato e 24h foram, respectivamente: GR1: 7.98HV ± 1.8 / 14.88HV ± 2.33; GR2: 4.84HV ± 0.13 / 9.06HV ± 1.63; GR3: 6.53HV ± 2.51 / 11.42HV ± 1.97. A baixa polimerização para o GR4 não permitiu a determinação da dureza inicial e após 24h este valor foi 10.65HV ± 0.92. O modo de ativação autopolimerizável influenciou negativamente o GC e a HV em relação ao modo de ativação no qual foi utilizada a fotoativação. A restauração simulada de porcelana não influenciou o GC, porém interferiu negativamente na microdureza. O tempo de fotoativação não influenciou os valores do GC e da HV. O GC e microdureza sofreram um aumento significativo após 24h da polimerização inicial, com exceção do GC no período inicial, quando a fotoativação foi realizada através de um disco de porcelana por um tempo de exposição de 20s. Houve uma correlação linear e positiva entre a HV e o GC para o cimento RelyX Unicem. Caracterização química: porção orgânica composta por uma mistura de monômeros, tendo o Bis-GMA como monômero-base. Presença de um monômero dimetacrilato contendo hidroxila para se ligar ao ácido fosfórico sob a forma de fosfato. Partículas inorgânicas variando entre 0,4 a 11,2m. A fração sólida do material é composta por 96% de partículas inorgânicas. Na fração líquida, a porção orgânica corresponde a 84%. Restou um resíduo incombustível de 16% devido à queima do material em atmosfera de nitrogênio.
- Published
- 2008
27. Evaluation of the influence of the mould material on the degree of conversion by infrared spectroscopy of a composite
- Author
-
Bordalo, Adriana Riedlinger Mont'alverne, Miranda, Mauro Sayão de, Mendes, Luis Claudio, Dias, Katia Regina Hostilio Cervantes, Mussel, Rogério Luiz de Oliveira, and Rabello, Tiago Braga
- Subjects
Polímeros ,Grau de conversão ,Composite resin ,Degree of conversion ,Resina composta ,Matriz ,Espectroscopia de infravermelho ,CIENCIAS DA SAUDE::ODONTOLOGIA [CNPQ] ,Espectrometria no infravermelho ,Dentina ,Infrared spectroscopy ,Mould ,Resinas dentárias - Abstract
Submitted by Boris Flegr (boris@uerj.br) on 2021-01-07T15:04:38Z No. of bitstreams: 1 DISSERTACAO_FINAL_Adriana_Riedlinger_MontAlverne_Bordalo.pdf: 2983865 bytes, checksum: 7018381e2bd90610b66b01af2e83082e (MD5) Made available in DSpace on 2021-01-07T15:04:38Z (GMT). No. of bitstreams: 1 DISSERTACAO_FINAL_Adriana_Riedlinger_MontAlverne_Bordalo.pdf: 2983865 bytes, checksum: 7018381e2bd90610b66b01af2e83082e (MD5) Previous issue date: 2007-12-18 This study was undertaken in order to determine, in vitro, the influence of mould material by the degree of conversion in a composite, and assess which of the materials tested was more akin to an array of dentin. The assessment was made by examining the degree of conversion (DC). Three bipartite moulds were made of black Teflon, white Teflon and stainless steel. All of them had 10 mm of diameter and 2 mm of deep. To the control group it was used a bovine central incisor, which had its buccal face leveled off in a sander under refrigeration with help of sandpaper 800. After that, this tooth was prepared in high speed with a diamond bur 2294 (KG Sorensen). This bur is proper for preparing standardized cavities for laboratories tests, and has a flat end with stop. A cavity of 2 mm of deep for 9 mm of diameter was obtained by a low speed that made the walls finished. With a cylindrical carbide bur 2056 (KG Sorensen), through the tooth lingual, a penetration was made until an extremely thin wall of dentin was obtained. Thus, with a needle, a little perforation was made in the center of this dentin. The specimens were made dispensed the restorative material on a single increment. A strip of cellulose was placed on top and a glass slab was pressed on the top. The material was cured during 40 seconds by halogen light, Optilux 501 (Demetron), with 500 mW/cm². Immediately, after cured, the specimens were submitted, on the top and on the bottom, to analyze their degree of conversion by FTIR. For the uncured composite was used the technique of the film leaked and for the cured composite, the technique of the potassium bromide tablet (KBr). Five specimens of each group had been confectioned. In each group, the bottom and top composite of the samples was worn out until if getting of 1,5 the 2,0 mg of dust and mixed with 70 mg of KBr, for attainment of the tablet of KBr . The analysis of FTIR was made. The absorptions selected for the calculation had been 1610 cm-1 and 1637 cm-1, the peaks of the specters of the linkings of aromatical and alifatic carbons, respectively. The data had been treated statistical. It could be concluded that the groups of black Teflon, white Teflon and stainless steel had not presented differences between the degree of conversion of the top and the bottom, whereas the group of the dentin presented greater conversion of the top. Comparing the moulds between them, it could be noticed that in the top, the DC of the bovine tooth is greater that the DC of the stainless steel and black Teflon, the DC of white Teflon is greater that the DC of the stainless steel and black Teflon. The top of the groups of bovine tooth and black teflon been similar. In the bottoms of the specimens, it did not have significant difference between the tested groups. In accordance with the results gotten in the experiment, could be concluded that in the groups of black Teflon, white Teflon and stainless steel it did not have difference between 0 and 2 mm, that is, top and bottom, its means that the material of mould confection did not influence the degree of conversion of the composite. Already for the group of the dentin, the top presented value of bigger conversion, showing that, in this in case that, the material of the matrix intervened with the DC. It can also be perceived that a trend of the white Teflon mould to resemble more the dentin mould, therefore was the only group that presented similarity in the values of DC in the top of the samples. However analyzing the bottom of the samples, all the groups had values of the degree of conversion without significant difference. Este estudo teve por objetivo avaliar, in vitro, a influência do material de confecção das matrizes, traçando um perfil da conversão monomérica de um compósito micro-híbrido, além de avaliar qual dos materiais testados mais se assemelha a uma matriz de dentina. A avaliação foi feita através da análise do grau de conversão (GC). Foram confeccionadas 3 matrizes bipartidas, sendo estas de teflon negro, tefon branco e aço inoxidável, ambas com 10mm de diâmetro e 2 mm de profundidade. Para o grupo controle foi utilizado um incisivo central bovino, o qual teve sua face vestibular aplainada em uma lixadeira sob refrigeração constante, com o auxílio de uma lixa de carbeto de silício, número 800. Após, este dente foi preparado com uma broca diamantada número 2294 (KG Sorensen) em alta rotação, própria para a preparação de cavidades padronizadas para ensaios de laboratório, apresentando um limitador de penetração. Em seguida, com um motor de baixa rotação foi realizado o acabamento das paredes, obtendo-se uma cavidade de 2,0 mm de profundidade por 9,0 mm de diâmetro. Pela palatina desse dente, com uma broca carbide cilíndrica de numeração 2056 (KG Sorensen), fez-se uma penetração até se obter uma parede de dentina extremamente fina, porém sem que esta fosse rompida. Assim, com uma agulha, fez-se uma pequena perfuração no centro dessa dentina para que este instrumental servisse como um pino para remoção do corpo de prova de dentro da matriz de dente. Os corpos de prova (CP) foram obtidos a partir da inserção do compósito no interior da perfuração das matrizes em um único incremento e cobertos na superfície externa com uma matriz de poliéster mais uma lamínula de vidro. Os CP foram fotopolimerizados por 40 s pela fonte de luz halógena Optilux 501 (Demetron), com 500 mW/cm². Imediatamente após a polimerização, os corpos de prova eram submetidos no topo e na base para a análise de espectrometria no infravermelho para a determinação da profundidade de polimerização, pela técnica do filme vazado para o compósito não polimerizado e pela técnica da pastilha de brometo de potássio (KBr) para o compósito polimerizado. Foram confeccionados 5 CP de cada grupo. Em cada grupo, o compósito da base e do topo das amostras foi moído até se obter de 1,5 a 2,0 mg de pó e misturado com 70 mg de KBr, para obtenção da pastilha de KBr . Foi feita a análise de espectrofotometria no infravermelho por Transformada de Fourier (FTIR). As absorções selecionadas para o cálculo foram 1610 cm-1 e 1637 cm-1, os picos dos espectros das ligações dos carbonos aromáticos e alifáticos, respectivamente. Os dados obtidos foram tratados estatisticamente. Os grupos Gr1B, Gr2B, Gr3B e Gr4B representam, respectivamente, as bases dos CP confeccionados pelas matrizes de DB, TN, TB e AI. Já os Gr1T, Gr2T, Gr3T e Gr4T representam os topos. Médias (%) e DP: Gr1T (46,46±1,99), Gr2T (39,86±4,51), Gr3T (44,05±3,44) e Gr4T (38,04±5,08). Gr1B (40,44±1,49), Gr2B (36,15±3,81), Gr3B (40,09±3,18) e Gr4B (35,59±3,35). Em posse dos resultados, pôde-se concluir que os grupos do teflon negro, teflon branco e aço inoxidável não apresentaram diferenças entre o grau de conversão do topo e da base, enquanto que o grupo da dentina apresentou maior conversão do topo. Comparando as matrizes entre elas, pôde-se perceber que no topo, o GC do dente bovino é maior que o GC do aço inoxidável e do que o de teflon negro, o GC do teflon branco é maior que o GC do aço inoxidável e do que o de teflon negro. Já o topo dos grupos de dente bovino e teflon banco foram semelhantes. Nas bases dos CPs, não houve diferença significativa entre os grupos testados. De acordo com os resultados obtidos no experimento, pôde-se concluir que nos grupos do teflon negro, teflon branco e aço inoxidável não houve diferença entre 0 e 2 mm, ou seja, topo e base, o que mostra que o material de confecção da matriz não influênciou o grau de conversão do compósito. Já para o grupo da matriz de dentina, o topo apresentou valor de conversão monomérica maior, mostrando que, neste caso, o material da matriz interferiu no grau de conversão. Pode-se perceber também que existe uma tendência da matriz de teflon branco se assemelhar mais a matriz de dentina, pois foi o único grupo que apresentou semelhança nos valores de conversão monomérica no topo das amostras. Porém analisando a base das amostras, percebe-se que todos os grupos se comportaram de forma semelhante, obtendo valores do grau de conversão sem diferença significante.
- Published
- 2007
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.