8 results on '"ARTIFICIAL blood circulation"'
Search Results
2. Escore de risco de sangramento em pacientes no pós-operatório imediato e precoce de cirurgia valvar.
- Author
-
de Carvalho Vieira, Alef, Tambellini Arnoni, Renato, da Silva Barbosa, Ana Beatriz, Santos Berriel, Attila, Guimarães Vianna, Rafael, and Issa, Mário
- Subjects
DISEASE risk factors ,POSTOPERATIVE period ,HEMOGLOBINS ,HEMORRHAGE ,SURGERY ,ARTIFICIAL blood circulation ,TRICUSPID valve surgery - Abstract
Copyright of Brazilian Journal of Cardiovascular Surgery is the property of Sociedade Brasileira de Cirurgia Cardiovascular and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2024
3. Funcionalidade e equilíbrio de pacientes submetidos à cirurgia cardíaca.
- Author
-
Cássio Magalhães da Silva E. Silva, Mansueto Gomes Neto, Ivana Oliveira De Lamonica Freire, Sara Carvalho de Oliveira Nogueira, Micheli B. Saquetto, Thaís Magalhães Cerqueira, and LaíssaCerqueira Lima Santos
- Subjects
ARTIFICIAL blood circulation ,CORONARY artery bypass ,POSTURAL balance ,CARDIAC patients ,LIFE skills ,LONGITUDINAL method ,NOSOLOGY ,POSTOPERATIVE period ,RESEARCH ,STATISTICS ,DATA analysis ,TREATMENT effectiveness ,FUNCTIONAL assessment ,DESCRIPTIVE statistics ,INFERENTIAL statistics ,KRUSKAL-Wallis Test - Abstract
Copyright of Fisioterapia Brasil is the property of Atlantica Editora and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2016
4. ASPECTOS HEMODINÂMICOS DA CIRCULAÇÃO EXTRACORPÓREA EM CÃES.
- Author
-
RIBEIRO KNUPP, SHEILA NOGUEIRA, VALE, DANIELA FANTINI, MONTEIRO, GUILHERME SOARES, LUZ, MÔNICA JORGE, SHEFFER, JUSSARA PETERS, and OLIVEIRA, ANDRÉ LACERDA
- Subjects
CARDIOPULMONARY bypass ,HEMODYNAMICS ,CARDIOPULMONARY system ,ARTIFICIAL blood circulation ,LABORATORY dogs ,VETERINARY cardiology ,SURGERY - Abstract
Copyright of Ciência Animal Brasileira is the property of Universidade Federal de Goias, Escola de Veterinaria and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2014
- Full Text
- View/download PDF
5. Atuação do enfermeiro frente aos efeitos da circulação extracorpórea.
- Author
-
Sartorio, Camila, Lima, Daniele Cristina Rocha, Metello, Flaviana De Castro, Soares, Olga Carla Ribeiro Costa, Mota, Valéria Cristina Moreira De Medeiros, and Souza, Flávia Silva De
- Subjects
ARTIFICIAL blood circulation ,NURSES ,SURGICAL complications ,LITERATURE reviews ,OCCUPATIONAL roles - Abstract
Copyright of Enfermagem Brasil is the property of Atlantica Editora and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2012
6. Função pulmonar após cirurgia de revascularização do miocárdiocom e sem circulação extracorpórea.
- Author
-
Broco, Letícia, Pasolini, Mariana Grazziotin, Scapini, Kátia Bilhar, Timm, Bárbara, Posser, Simone Regina, Rockenbach, Carla Wouters Franco, da Silveira de Barcellos, Christiano, Tognon, Alexandre Pereira, and Leguisamo, Camila Pereira
- Subjects
PULMONARY function tests ,CORONARY artery bypass ,MYOCARDIAL revascularization ,ARTIFICIAL blood circulation ,VITAL capacity (Respiration) ,SURGICAL complications ,RESPIRATORY measurements ,PREOPERATIVE period ,PATIENTS - Abstract
Copyright of Scientia Medica is the property of EDIPUCRS - Editora Universitaria da PUCRS and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2010
7. Fórmula de cálculo do volume de ultrafiltrado extraído pela ultrafiltração modificada, em indivíduos adultos.
- Author
-
Gonçalves, Ana Sofia, Figueira, Maria Inês, Franco, Paulo Jorge, and Raposo, Susana Martins
- Subjects
- *
ULTRAFILTRATION , *CARDIAC surgery , *OLDER patients , *ARTIFICIAL blood circulation , *BODY surface mapping , *PERFUSION , *REGRESSION analysis , *HEMOGLOBINS , *HEMOPERFUSION - Abstract
The main purpose of this study is to determine a formula for calculation of the volume of ultrafiltrate to be extracted by Modified Ultrafiltration (MUF) from adult patients undergoing heart surgery. The target population includes 489 cases corresponding to the heart surgeries performed from January 2003 to December 2005 meeting the inclusion and exclusion criteria that have been established. It is a retrospective, correlational and quantitative study that takes a deductive approach, with the studied variables having been collected from the cardiovascular perfusion reports of the Cardiothoracic Surgery Unit of Hospital de Santa Marta, EPE. The relation between the variables being studied was studied by means of correlation and linear regression models. The model obtained to define the formula of calculation wanted takes the existent correlation as a base between the volume to take out for MUF and the body surface of the patient, when there is this the only one of three studied models that demonstrates a dependence, still weak that, between the variables, and being expressed through the formula: Y=545,4.X3, in that Y is the volume take out for MUF and X is the value of the body surface of each patient, and being representative only for 4% of the population in study. The average increase of hemoglobin value after MUF is 1,9±1,09g/dl, which evidences the efficacy of this technique in obtaining hemoconcentration. [ABSTRACT FROM AUTHOR]
- Published
- 2008
8. Membrane blood oxygenator evaluation using mass transfer principles and head loss techniques
- Author
-
Luis Melchert Faber Schmutzler, Arruda, Antonio Celso Fonseca de, 1948, Novello, Waldyr Parolari, Zavaglia, Cecília Amélia de Carvalho, Freire, Celia Marina de Alvarenga, Zemp, Roger Josef, Biscegli, Jose Francisco, Universidade Estadual de Campinas. Faculdade de Engenharia Mecânica, and UNIVERSIDADE ESTADUAL DE CAMPINAS
- Subjects
Fluorcarbon ,Massa - Transferência ,Análise funcional ,Mass transfer ,Blood oxygenators ,Sangue - Circulação extracorpórea ,Artificial blood circulation ,Oxigenadores - Abstract
Orientadores: Antonio Celso Fonseca de Arruda e Waldyr Parolari Novello Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica Resumo: Oxigenadores de sangue tipo de membrana são construídos para trocarem gases de respiração através de uma área de contato, a sua chamada área de troca. Devido a características do processo de fabricação, esta área pode softer variações. Neste trabalho procurou-se desenvolver métodos de avaliação da variação desta área, por meio da medição da transferência de massa e da perda de carga. A técnica utilizando transferência de massa gerou dois métodos de avaliação, um utilizando como fase líquida a água destilada e o outro, uma emulsão de perfluorcarbono. No intuito de assegurar a funcionalidade da emulsão disponível e assim a precisão do trabalho, foi desenvolvido um método de validação para se avaliar a capacidade de dissolver Oxigênio da mesma. O outro método para avaliação da área de troca é baseado naperda de carga, sofrida por um fluxo de gás ao percorrer o circuito de membranas do oxigenador sob teste. Todos os métodos apresentaram resultados suficientemente satisfatórios, permitindo estabelecer diferenças de desempenho entre as unidades testadas e a validação da área de troca, por comparação com um padrão sendo que, os métodos de transferência de massa com água e o da perda de carga com gás são métodos não destrutivos. Os resultados obtidos utilizando-se o método com gás forneceram uma melhor resolução Abstract: Membrane blood oxygenators are built to exchange perspiration gases thru an exchange area, but due to the fabrication process characteristics, this exchange area may vary. In this work, exchange area evaluation methods were developed using mass transfer and head loss techniques. The mass transfer technique generated two methods, one using distilled water and other using perfluorocarbon emulsion. Envisaging assurance on the functionality of the perfluorocarbon emulsion and by the way, the quality of the work, a method for evaluating the Oxygen solving capability was also developed. The other area evaluation method is based on a gas flow head loss while passing thru the membrane inside of the under testing device. Ali methods presented satisfactory results, allowing establishing performance differences among tested units and the area validation by comparing to a standard device. The mass transfer water based and the gas flow head loss are non destructive methods. The results provided by the gas flow head loss method achieved a better level of resolution Doutorado Materiais e Processos de Fabricação Doutor em Engenharia Mecânica
- Published
- 2004
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.