1. Evaluation of a microscale quantitative suspension test to determine the bactericidal and yeasticidal activity of glutaral – one step to improve sustainability in disinfectant testing
- Author
-
Gebel, Jürgen, Rausch, Marvin, Bienentreu, Katja, Droop, Felix, Eggers, Maren, Gebel, Lea, Gemein, Stefanie, Hornei, Britt, Ilschner, Carola, Jacobshagen, Anja, Kampf, Günter, Papan, Cihan, Roesch, Kira, Schmitz, Luisa, Suchomel, Miranda, Vossebein, Lutz, Mutters, Nico T., and Exner, Martin
- Subjects
suspension test ,bactericidal activity ,yeasticidal activity ,micromethod ,microscale suspension test ,sustainability ,glutaral ,Medicine ,Public aspects of medicine ,RA1-1270 ,Microbiology ,QR1-502 - Abstract
Aims: To evaluate a newly developed microscale quantitative suspension test compared to the existing standard suspension test using determination of the bactericidal and yeasticidal activity of glutaral as one step to improve the sustainability of disinfectant testing.Methods: The testing principles of the quantitative suspension test according to VAH method 9 (comparable to EN 13727) was used as a standard suspension test using 8.0 mL product test solution, 1.0 mL organic load and 1.0 mL test suspension. In addition, a micro-scale suspension test was performed in 96-well plates with 160 µL product test solution, 20 µL organic load and 20 µL test suspension. ATCC 6538, ATCC 15442 and ATCC 10231 were test organisms. Glutaral was tested at concentrations of 0.05%, 0.1%, 0.2% and 0.3% with exposure times of 1, 5 and 15 min. Polysorbate 80 (30 g/L), lecithin (9 g/L), L-histidine (1 g/L) and glycine (1/L) were used as validated neutralizers. After serial dilution of the disinfectant-neutralizer-mixture, plates were incubated for 48 h at 36°C (bacteria) or 72 hours at 30°C () and colony forming units (cfu) counted. The lg reduction was calculated as the difference between the results of the water control and the disinfectant at the end of the exposure time. All experiments were done in triplicate under clean conditions. Means of lg reduction were compared with the unpaired test, p
- Published
- 2024
- Full Text
- View/download PDF