1. Comparative Study on Performance of Renewable Energy Building Energy Supply System
- Author
-
Xiufang Jiang, Rongdan Diao, Li Zeng, Ying Zhang, and Xinrong Lei
- Subjects
Environmental sciences ,GE1-350 - Abstract
The air source heat pump water system test bench and the compact all-glass vacuum tube solar water heating system test bench are (were) built on the roof of two adjacent teacher’s apartment buildings with the same structure, shape and material were constructed to study the performance of energy supply systems for different types of renewable energy buildings. The energy supply system performance and the performance parameters are comprehensively and systematically analyzed in the same environment conditions of the same period. The results show that the weight coefficients of the performance parameters of the two energy supply systems are equal by means of extension theory analysis. At the last, the comprehensive correlation degree Kj(1) of water outlet temperature on the performance of renewable energy power supply system is 2.07, the comprehensive correlation degree Kj(2) of water inlet temperature is 2.04, the comprehensive correlation degree Kj(3) of air temperature is 2.14, the comprehensive correlation degree Kj(4) of solar radiation is 4.97, and the comprehensive correlation degree Kj(5) of sunshine hours is 3.78.
- Published
- 2021
- Full Text
- View/download PDF