19 results on '"CONE beam computed tomography"'
Search Results
2. CLINICAL AND RADIOGRAPHIC PERIODONTAL PARAMETERS: COMPARISON WITH SOFTWARE GENERATED CBCT MEASUREMENTS.
- Author
-
Sreih, Rachid, Ghosn, Nabil, Chakar, Carole, Mokbel, Nadim, and Naaman, Nada Bou Abboud
- Subjects
- *
PERIAPICAL diseases , *LENGTH measurement - Abstract
Periodontal diagnosis relies mainly on clinical assessment and radiographic images. The increasing accuracy of CBCT images and the corresponding advancement in computer software for data extraction can be of great help in periodontal diagnosis for bone loss and furcation defects. Thus, the aim of this study was to compare direct surgical measurements to data extracted from periapical radiographs and CBCT by means of software (coPeriodontix™ and Blue Sky Plan®) in order to assess the accuracy delivered by these software. Ten patients were included in the study, the number of teeth selected for measurements ranged from one to 10 per patient. Overall: i- 251 measures were included for comparison of linear measurements between surgical and CBCT, ii- 69 measures were compared between surgical and periapical radiographs, iii- 20 furcation defects were recorded peroperatively for comparison with CBCT and periapical radiographs data. All CBCT scans and X-rays were acquired within a maximum period of 1 month prior to surgery. Clinical linear measurements were performed at 6 sites for each tooth, from the cemento-enamel junction to the marginal bone level at the buccal, buccal-mesial, buccal-distal, lingual, lingual-mesial, and lingualdistal side. Furcation defects were recorded according to the classification of Hamp in 1975. Differences between data acquired from these 3 modalities were analyzed. Intra-surgical measurements were considered as "gold standard". Statistical significance was found between the three modalities concerning linear measurements. CBCT showed less bone loss while intrasurgical measurements showed more bone loss. Furcation defects were similar between CBCT and intra-surgical measurement (p =1). Intra-oral radiographs showed 38.88% accuracy for furcation defects. The coPeriodontix ™ tended to underestimate the real bone loss. The Blue Sky Plan® accurately depicted the true furcation defect. [ABSTRACT FROM AUTHOR]
- Published
- 2019
- Full Text
- View/download PDF
3. Évaluation et choix des protocoles d’imagerie sur le système de tomographie conique de basse énergie XVI® d’Elekta.
- Author
-
Werlé, F., Buffard, E., Brune, K., Perrin, B., and Atlani, D.
- Subjects
- *
MEDICAL protocols , *CONE beam computed tomography , *IMAGING of cancer , *RADIATION doses , *CANCER patients , *CANCER radiotherapy - Abstract
Résumé: Objectif de l’étude: Ce travail propose une évaluation du système de tomographie conique de basse énergie XVI® d’Elekta. La dose moyenne délivrée pour chaque protocole d’acquisition proposé par défaut par le constructeur est mesurée au moyen de plusieurs détecteurs et est comparée aux valeurs de dose théorique fournies par Elekta. En parallèle, une évaluation de la qualité d’image pour les protocoles pelviens, corrélée à des mesures de dose en milieu homogène et hétérogène, a permis d’aboutir à une optimisation de l’utilisation du XVI®. Matériel et méthodes: La dose a été mesurée pour l’ensemble des protocoles du constructeur (en faisant varier les filtres, les largeurs de FOV et les collimations) à l’aide de quatre détecteurs (chambre crayon, chambres cylindriques 0,3cm3 et 0,125cm3, pastilles thermoluminescentes) dans un fantôme CTDI. L’évaluation de la dose en milieu hétérogène a été réalisée dans un fantôme anthropomorphe expérimental simulant un pelvis masculin. La qualité d’image a été évaluée au moyen du fantôme Catphan® 600. Résultats: La dose moyenne mesurée en milieu homogène était de l’ordre de 17mGy et 25mGy par acquisition pour les protocoles Pelvis et Prostate et de 17mGy et 1mGy pour les protocoles Poumon et ORL. L’étude menée avec différents détecteurs a montré que les doses obtenues étaient du même ordre de grandeur (±10 %) et en accord avec celles fournies par le constructeur. L’évaluation de la qualité d’image, corrélée avec la dose moyenne mesurée, a permis d’optimiser l’utilisation des protocoles d’acquisitions XVI®. L’analyse de résultats des mesures en milieu hétérogène a montré une diminution de la dose au contact de l’hétérogénéité d’un facteur 1,5 pour l’os et d’un facteur 2 pour le titane. Conclusion: L’étude a montré que les doses théoriques proposées par le constructeur pouvaient être utilisées pour estimer la dose moyenne délivrée au patient par tomographie conique de basse énergie. L’analyse de l’ensemble des résultats a abouti à appliquer une procédure au sein du service de radiothérapie permettant de relever et d’optimiser la dose délivrée au patient par imagerie de basse énergie, de la comptabiliser et de la tracer dans le dossier du patient. [ABSTRACT FROM AUTHOR]
- Published
- 2014
- Full Text
- View/download PDF
4. Applications of multimodal imaging in interventional neuroradiology angiousuites
- Author
-
Caroff, Jildaz, Laboratoire de Recherche Vasculaire Translationnelle (LVTS (UMR_S_1148 / U1148)), Institut National de la Santé et de la Recherche Médicale (INSERM)-Université Paris Cité (UPCité)-Université Sorbonne Paris Nord, Université Paris-Nord - Paris XIII, Laurent Spelle, and STAR, ABES
- Subjects
Imagerie volumique par faisceau conique ,[SDV.EE.SANT]Life Sciences [q-bio]/Ecology, environment/Health ,Anévrisme intracrânien ,Optical coherence tomography ,Tomographie en cohérence optique ,Cone beam computed tomography ,[SDV.EE.SANT] Life Sciences [q-bio]/Ecology, environment/Health ,Interventional neuroradiology ,Intracranial aneurysm ,Neuroradiologie interventionnelle - Abstract
Since the very beginning of Interventional Neuroradiology (INR), the two pillars of this young specialty born in the 1960-70 have been both technological innovation and imaging. Thanks to numerous evolutions, we now can navigate our catheters anywhere in the brain. And all the available devices allow us to open an obstructed artery, occlude an hemorrhagic lesion or reconstruct a pathological vessel. The resolution of digital subtraction angiography has gradually improved over the years but up until recently we did not benefit from diverse options to plan and evaluate our treatments. The first part of this work consisted in demonstrating the clinical potential of a widely available but underused modality, the Cone Beam Computed Tomography. It allows a very good visualization of devices presenting a low radiodensity. In a second part, we exposed through multiple preclinical models, the potential impact of intravascular imaging with optical coherence tomography. Only used in the cardiology field, it could become an in vivo microscope for the analysis of neurovascular diseases and their treatment. Finally, after the description of morphological imaging modalities, we demonstrated the interest of functional imaging for the treatment planning of the cerebrovascular diseases managed by INR. We will illustrate this imaging progression through two very different approaches to treat intracranial aneurysms ; one endosaccular (WEB device) the other parietal (Flow diverter stents). In total, the importance of imaging is continuously growing in our field, because of the diversification of INR imaging. There is no doubt that in few years from now the multiplicity of these data will be provided through advanced reality systems similarly with pilots helmet mounted displays. In the future, it is possible that treatments will even be performed through imaging when magnetic resonance system will allow the remote navigation of catheters up to their pathological target, Les deux piliers de la Neuroradiologie Interventionnelle (NRI) sont depuis la naissance de cette spécialité née dans les années 1960-70 : la technicité des « outils » employés et le guidage par l’image. Grace à des avancées technologiques majeures, nos cathéters nous autorisent désormais à naviguer dans n’importe quelle artère du cerveau. Et l’ensemble des dispositifs de NRI existants nous permet de désobstruer une artère occlue, emboliser une lésion à risque de saignement ou bien reconstruire des vaisseaux pathologiques. En revanche, si la résolution de l’angiographie numérique s’est progressivement améliorée au fil des années, nous ne disposions encore récemment que de peu d’éléments pour planifier et évaluer précisément nos traitements, ceci directement au bloc de NRI.La première partie de ce travail a consisté à démontrer le potentiel d’une technologie largement disponible mais sous-employée. L’imagerie volumique par faisceau conique (Cone Beam CT) est en effet une aide précieuse pour imager les dispositifs faiblement radio-opaques. Dans un deuxième temps, nous exposons au travers de plusieurs modèles précliniques, le potentiel extraordinaire de l’imagerie intra-vasculaire par tomographie en cohérence optique (Optical Coherence Tomography). Non utilisée en pratique clinique NRI jusqu’à ce jour, cette imagerie à très haute résolution a le potentiel de devenir un véritable microscope vasculaire utilisable in vivo. Enfin, après la description des ces modalités morphologiques nous nous sommes efforcés de démontrer la valeur ajoutée des imageries fonctionnelles lors du traitement des pathologies neurovasculaires. Nous illustrons cette progression dans les techniques d’imagerie au travers de deux approches différentes pour le traitement des anévrismes intracrâniens ; l’une endosacculaire (WEB) et l’autre pariétale (stents à diversion de flux).Au total, l’importance de l’imagerie dans notre spécialité est encore en train de se renforcer, en raison de sa diversification. Il ne fait aucun doute que dans un avenir proche, la multiplicité des informations fournies sera disponible, en temps réel, par réalité augmentée, à la manière d’un pilote d’avion. Dans le futur, c’est même par l’imagerie que nous réaliserons nos interventions ; quand les systèmes à résonnance magnétique permettront de guider, à distance les cathéters jusqu’à leur cible.
- Published
- 2019
5. Apport de l’imagerie multimodale avancée au bloc de neuroradiologie interventionnelle
- Author
-
Caroff, Jildaz, Laboratoire de Recherche Vasculaire Translationnelle (LVTS (UMR_S_1148 / U1148)), Institut National de la Santé et de la Recherche Médicale (INSERM)-Université de Paris (UP)-Université Sorbonne Paris Nord, Université Paris-Nord - Paris XIII, and Laurent Spelle
- Subjects
Imagerie volumique par faisceau conique ,[SDV.EE.SANT]Life Sciences [q-bio]/Ecology, environment/Health ,Anévrisme intracrânien ,Optical coherence tomography ,Tomographie en cohérence optique ,Cone beam computed tomography ,Interventional neuroradiology ,Intracranial aneurysm ,Neuroradiologie interventionnelle - Abstract
Since the very beginning of Interventional Neuroradiology (INR), the two pillars of this young specialty born in the 1960-70 have been both technological innovation and imaging. Thanks to numerous evolutions, we now can navigate our catheters anywhere in the brain. And all the available devices allow us to open an obstructed artery, occlude an hemorrhagic lesion or reconstruct a pathological vessel. The resolution of digital subtraction angiography has gradually improved over the years but up until recently we did not benefit from diverse options to plan and evaluate our treatments. The first part of this work consisted in demonstrating the clinical potential of a widely available but underused modality, the Cone Beam Computed Tomography. It allows a very good visualization of devices presenting a low radiodensity. In a second part, we exposed through multiple preclinical models, the potential impact of intravascular imaging with optical coherence tomography. Only used in the cardiology field, it could become an in vivo microscope for the analysis of neurovascular diseases and their treatment. Finally, after the description of morphological imaging modalities, we demonstrated the interest of functional imaging for the treatment planning of the cerebrovascular diseases managed by INR. We will illustrate this imaging progression through two very different approaches to treat intracranial aneurysms ; one endosaccular (WEB device) the other parietal (Flow diverter stents). In total, the importance of imaging is continuously growing in our field, because of the diversification of INR imaging. There is no doubt that in few years from now the multiplicity of these data will be provided through advanced reality systems similarly with pilots helmet mounted displays. In the future, it is possible that treatments will even be performed through imaging when magnetic resonance system will allow the remote navigation of catheters up to their pathological target; Les deux piliers de la Neuroradiologie Interventionnelle (NRI) sont depuis la naissance de cette spécialité née dans les années 1960-70 : la technicité des « outils » employés et le guidage par l’image. Grace à des avancées technologiques majeures, nos cathéters nous autorisent désormais à naviguer dans n’importe quelle artère du cerveau. Et l’ensemble des dispositifs de NRI existants nous permet de désobstruer une artère occlue, emboliser une lésion à risque de saignement ou bien reconstruire des vaisseaux pathologiques. En revanche, si la résolution de l’angiographie numérique s’est progressivement améliorée au fil des années, nous ne disposions encore récemment que de peu d’éléments pour planifier et évaluer précisément nos traitements, ceci directement au bloc de NRI.La première partie de ce travail a consisté à démontrer le potentiel d’une technologie largement disponible mais sous-employée. L’imagerie volumique par faisceau conique (Cone Beam CT) est en effet une aide précieuse pour imager les dispositifs faiblement radio-opaques. Dans un deuxième temps, nous exposons au travers de plusieurs modèles précliniques, le potentiel extraordinaire de l’imagerie intra-vasculaire par tomographie en cohérence optique (Optical Coherence Tomography). Non utilisée en pratique clinique NRI jusqu’à ce jour, cette imagerie à très haute résolution a le potentiel de devenir un véritable microscope vasculaire utilisable in vivo. Enfin, après la description des ces modalités morphologiques nous nous sommes efforcés de démontrer la valeur ajoutée des imageries fonctionnelles lors du traitement des pathologies neurovasculaires. Nous illustrons cette progression dans les techniques d’imagerie au travers de deux approches différentes pour le traitement des anévrismes intracrâniens ; l’une endosacculaire (WEB) et l’autre pariétale (stents à diversion de flux).Au total, l’importance de l’imagerie dans notre spécialité est encore en train de se renforcer, en raison de sa diversification. Il ne fait aucun doute que dans un avenir proche, la multiplicité des informations fournies sera disponible, en temps réel, par réalité augmentée, à la manière d’un pilote d’avion. Dans le futur, c’est même par l’imagerie que nous réaliserons nos interventions ; quand les systèmes à résonnance magnétique permettront de guider, à distance les cathéters jusqu’à leur cible.
- Published
- 2019
6. Imagerie du système stylo-hyoïdien : variabilité chez l-homme.
- Author
-
SCANTEIE, Raluca and PASQUET, Gérard
- Subjects
- *
PANORAMIC radiography , *DENTAL radiography , *HUMAN abnormalities , *DENTAL pathology , *SEX factors in disease , *AGE factors in disease , *CONE beam computed tomography , *DIAGNOSTIC imaging , *PATIENTS - Abstract
The purpose of our study is to analyse the stylo-hyoid complex on the orthopantogram. It is based on 350 dental panoramic X-ray samples. It shows the length variability and the most common morphology according to the age and the sex of the patients. [ABSTRACT FROM AUTHOR]
- Published
- 2012
- Full Text
- View/download PDF
7. Intérêts et limites des expanseurs vissés de MIS® aux maxillaires : illustration à partir de cas cliniques et comparaison du volume osseux à partir de clichés radiographiques tridimensionnels.
- Author
-
Guillemant, H., Mouigha, A., Vienne, A., Libersa, J.-C., and Ferri, J.
- Subjects
JAW abnormalities ,BONE grafting ,BONE density ,COMPARATIVE studies ,THREE-dimensional imaging ,RADIOGRAPHY - Abstract
Copyright of Revue de Stomatologie & de Chirurgie Maxillo-Faciale is the property of Masson SPA and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2012
- Full Text
- View/download PDF
8. Évaluation économique prospective de la radiothérapie guidée par l’image des cancers de la prostate dans le cadre du programme national de soutien aux thérapeutiques innovantes et coûteuses
- Author
-
Pommier, P., Morelle, M., Perrier, L., de Crevoisier, R., Laplanche, A., Dudouet, P., Mahé, M.-A., Chauvet, B., Nguyen, T.-D., Créhange, G., Zawadi, A., Chapet, O., Latorzeff, I., Bossi, A., Beckendorf, V., Touboul, E., Muracciole, X., Bachaud, J.-M., Supiot, S., and Lagrange, J.-L.
- Subjects
- *
IMAGE-guided radiation therapy , *LONGITUDINAL method , *PROSTATE cancer treatment , *MEDICAL economics , *PATIENT positioning , *MEDICAL quality control , *COMPARATIVE studies - Abstract
Abstract: Purpose: The main objective of the economical study was to prospectively and randomly assess the additional costs of daily versus weekly patient positioning quality control in image-guided radiotherapy (IGRT), taking into account the modalities of the 3D-imaging: tomography (CBCT) or gold seeds implants. A secondary objective was to prospectively assess the additional costs of 3D versus 2D imaging with portal imaging for patient positioning controls. Patients and methods: Economics data are issued from a multicenter randomized medico-economics trial comparing the two frequencies of patient positioning control during prostate IGRT. A prospective cohort with patient positioning control with PI (control group) was constituted for the cost comparison between 3D (IGRT) versus 2D imaging. The economical evaluation was focused to the radiotherapy direct costs, adopting the hospital''s point of view and using a microcosting method applied to the parameters that may lead to cost differences between evaluated strategies. Results: The economical analysis included a total of 241 patients enrolled between 2007 and 2011 in seven centres, 183 in the randomized study (128 with CBCT and 55 with fiducial markers) and 58 in the control group. Compared to weekly controls, the average additional cost per patient of daily controls was €847 (CBCT) and €179 (markers). Compared to PI, the average additional cost per patient was €1392 (CBCT) and €997 (fiducial markers) for daily controls; €545 (CBCT) and €818 (markers) in case of weekly controls. Conclusion: A daily frequency for image control in IGRT and 3D images patient positioning control (IGRT) for prostate cancer lead to significant additional cost compared to weekly control and 2D imaging (PI). Long-term clinical assessment will permit to assess the medico-economical ratio of these innovative radiotherapy modalities. [Copyright &y& Elsevier]
- Published
- 2012
- Full Text
- View/download PDF
9. Imagerie Cone Beam et implants.
- Author
-
Cavézian, R. and Pasquet, G.
- Subjects
CONE beam computed tomography ,DENTAL implants ,RADIOLOGISTS ,MAXILLOFACIAL surgery ,MEDICAL artifacts ,DATA analysis - Abstract
Copyright of Revue de Stomatologie & de Chirurgie Maxillo-Faciale is the property of Masson SPA and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2012
- Full Text
- View/download PDF
10. Place de la tomographie volumique à faisceau conique en imagerie dento-maxillofaciale.
- Author
-
BENJELLOUN, Laila, EL HARTI, Karima, and EL WADY, Wafaa
- Subjects
- *
CONE beam computed tomography , *DIAGNOSTIC imaging , *ODONTOGENIC tumors , *MOLARS , *TRAUMATISM - Abstract
Cone beam computed tomography is a relatively new imaging technology that allows visualizing the complete maxillofacial complex. Its technique, low dosimetry and its low price comparing with CT scanner permit to propose it as an alternative of the CT scanner, especially in some clinical applications such as odontogenic tumors, maxillofacial trauma, implantology and the relationship of third molars with the surrounding structures... This promising technology is now widely diffused. It is therefore important to show the reel place of cone beam computed tomography in dentomaxillofacial imaging. [ABSTRACT FROM AUTHOR]
- Published
- 2012
- Full Text
- View/download PDF
11. Localisation de l'apex des canines incluses palatines.
- Author
-
MAIRE, Claire-HÉLÈN
- Subjects
ROOT apexes (Dentistry) ,DENTAL radiography ,MAXILLA abnormalities ,CONE beam computed tomography ,ORTHODONTICS ,DENTAL arch - Abstract
Copyright of Orthodontie Française is the property of John Libbey Eurotext Ltd. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2012
- Full Text
- View/download PDF
12. Imagerie des désordres temporo-mandibulaires.
- Author
-
FELIZARDO, Rufino, FOUCART, Jean-Michel, and PIZELLE, Christophe
- Subjects
MEDICAL imaging systems ,DENTAL radiography ,CLINICAL indications ,CONE beam computed tomography ,RADIOGRAPHIC films ,MAGNETIC resonance imaging ,MANDIBULAR prosthesis - Abstract
Copyright of Orthodontie Française is the property of John Libbey Eurotext Ltd. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2012
- Full Text
- View/download PDF
13. Les erreurs de mesure en céphalométrie 3D : à propos de l’analyse cranio-faciale vestibulaire.
- Author
-
DE PAPÉ, Romain, PIZELLE, Christophe, and FOUCART, Jean-Michel
- Subjects
MEASUREMENT errors ,MEDICAL imaging systems ,THREE-dimensional imaging ,CEPHALOMETRY ,CRANIAL manipulation ,TOMOGRAPHY ,POSITRON emission tomography ,CONE beam computed tomography ,ORTHODONTISTS - Abstract
Copyright of Orthodontie Française is the property of John Libbey Eurotext Ltd. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2012
- Full Text
- View/download PDF
14. Techniques radiographiques utiles en orthodontie.
- Author
-
FELIZARDO, Rufino, THOMAS, Alexis, and FOUCART, Jean-Michel
- Subjects
DENTAL radiography ,ORTHOPEDICS ,CEPHALOMETRY ,TOMOGRAPHY ,OCCLUSAL adjustment ,PANORAMIC radiography ,ORTHODONTISTS ,CONE beam computed tomography - Abstract
Copyright of Orthodontie Française is the property of John Libbey Eurotext Ltd. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
- Published
- 2012
- Full Text
- View/download PDF
15. La tomographie volumétrique numérisée par le système NewTom : intérêt de ce nouvel examen d'imagerie médicale chez l'enfant
- Author
-
Rouas, P., Bandon, D., Nancy, J., Delbos, Y., Hauret, L., and Bar, D.
- Subjects
- *
DIAGNOSTIC imaging , *X-rays , *TOMOGRAPHY , *DENSITOMETRY , *PEDIATRICIANS - Abstract
Abstract: In some cases, after preliminary clinical examination, medical imaging can provide indispensable complementary information for the care of young patients. Volume imaging using two- and three-dimensional reconstructions provides the most complete information possible. Problems involving the superposition of anatomical structures, which can occur with conventional X-rays, are a thing of the past, and this technique represents the future in this field. In high-density tissue such as bone or teeth, tomodensitometry is the preferred examination as it can give a three-dimensional approach to the study. However, because of the high radiation dose required, scanner is still a second intention examination. Development of digital volume tomography using NewTom system, designed for maxillofacial exploration, produces the same type of image for a very much reduced X-ray dose, and at low cost. Although the use of this new examining technique is developing rapidly in Europe and throughout the world since its recent introduction, France is lagging behind as to date there are only seven machines in the entire country. The main uses in children, illustrated by original clinical cases, relate to preoperative surgery planning, post-trauma diagnostic workups, orthodontic checkups, postoperative follow-up and TMJ examinations. The purpose of this article is to inform dental surgeons, paediatricians and doctors about this new medical imaging examination, which will most definitely have a place in the battery of diagnostic tools available to us. After weighing the advantages/risks involved, it should be possible to reduce the number of tomodensitometry exams in favour of this new examination technique in children according to the clinical examination data and diagnostic information required. [Copyright &y& Elsevier]
- Published
- 2006
- Full Text
- View/download PDF
16. Identification par cone beam computed tomography des lésions osseuses et dentaires associées aux canines incluses maxillaires : étude rétrospective
- Author
-
Perrier, Lucille, Aix-Marseille Université - Faculté d'odontologie (AMU ODONTO), Aix Marseille Université (AMU), and Émilie Quinque
- Subjects
MESH: Procédures de chirurgie maxillofaciale et buccodentaire ,MESH: Orthodontie correctrice ,Cone beam computed tomography ,Traitement orthodontique ,MESH: Canine--imagerie diagnostique ,[SDV.MHEP.CHI]Life Sciences [q-bio]/Human health and pathology/Surgery ,Canine incluse maxillaire ,Résorption radiculaire ,MESH: Dent incluse ,MESH: Éruption dentaire ectopique ,MESH: Tomodensitométrie à faisceau conique ,Traitement chirurgical ,MESH: Rhizalyse - Abstract
Objective: The aim of this study is to identify, thanks to the CBCT, the bone and dental lesions associated with the impacted maxillary canines, and to demonstrate how this radiological examination should become the reference in the management of the impacted canines. Materials and Methods: 42 patients were included in this retrospective study (33 women and 9 men), with an average age of 16.5 years. Panoramic radiographs and CBCT collected for each patient were studied: the location (vestibular, palatal, mesial and distal), the height of the inclusion, the orientation of the included canines; the root resorption volumes of adjacent teeth have been calculated, using Osirix Lite (3D imaging software), and every bone and dental lesions visible on CBCTs were identified. Results: We identified 58 maxillary canines in 42 patients. The inclusion of maxillary canines affects women more often (78.57%). Canines are more often impacted in palatal side (60.34% of cases). In 58% of cases, there is a root resorption of adjacent teeth (69% for the lateral incisors, 13% for the central incisors and 18% for the first premolars). Other dental and bone lesions have been observed (follicular sac hypertrophy, root dilaceration, odontoma, transposition, sinusitis). Conclusion: Many fortuitous discoveries are detected during this examination, especially root resorptions which represent the most encountered lesions. The CBCT brings many information thanks to its 3D images, and constitutes a relevant tool in the study of the maxillary impacted canines, in order to establish an accurate diagnosis and the most suitable orthodontic, surgical, periodontal, endodontic management.; Objectif : L’objectif de cette étude est d’identifier, grâce au CBCT, les lésions osseuses et dentaires associées aux canines incluses maxillaires, et de déterminer en quoi celui-ci doit devenir l’examen de référence dans la gestion des canines incluses. Matériels et Méthodes : 42 patients ont été inclus dans cette étude rétrospective, parmi lesquels 33 femmes et 9 hommes, avec une moyenne d’âge de 16,5 ans. À l ‘aide de radiographies panoramiques et des CBCT recueillis auprès des patients inclus dans l’étude, ont été étudiées : la localisation (vestibulaire, palatine, mésiale et distale), la hauteur d’inclusion, l’orientation des canines incluses ; les volumes de résorption des dents adjacentes ont été calculés, à l’aide d’un logiciel d’exploitation des images 3D Osirix Lite, et l’ensemble des lésions osseuses et dentaires visibles sur les CBCT ont été répertoriées. Résultats : Nous avons donc recensé 58 canines incluses maxillaires chez 42 patients. L’inclusion des canines maxillaires touche plus souvent les femmes (78,57%). Les canines sont le plus souvent incluses en palatin (60,34% des cas). Dans 58% des cas, il y a une résorption radiculaire des dents adjacentes (69% pour les incisives latérales, 13% pour les incisives centrales et 18% pour les premières prémolaires). D’autres lésions dentaires et osseuses ont été observées (hypertrophie du sac folliculaire, dilacération radiculaire, odontome, transposition, sinusite). Conclusion : De nombreuses découvertes fortuites sont détectées lors de cet examen, notamment les résorptions radiculaires qui représentent les lésions les plus fréquemment rencontrées. Le CBCT, de par l’ensemble des images dans les trois dimensions de l’espace qu’il apporte, constitue un outil pertinent dans l’étude des canines incluses maxillaires, pour un diagnostic précis et une prise en charge orthodontique, chirurgicale, parodontale, endodontique, la mieux adaptée.
- Published
- 2018
17. Cone beam CT in orthodontics: the current picture
- Author
-
Jimmy Makdissi
- Subjects
medicine.medical_specialty ,Cone beam computed tomography ,Quality Assurance, Health Care ,medicine.medical_treatment ,Orthognathic surgery ,Root Resorption ,Orthodontics ,Root resorption ,Evidence-Based Dentistry ,Radiation Dosage ,Imaging, Three-Dimensional ,Practice Management, Dental ,Medicine ,Humans ,Medical physics ,Tooth, Unerupted ,Radiation treatment planning ,Cone beam ct ,Incidental Findings ,business.industry ,Orthognathic Surgery ,Health Plan Implementation ,Cone-Beam Computed Tomography ,medicine.disease ,Cleft Palate ,Tooth, Supernumerary ,Practice Guidelines as Topic ,Malocclusion ,business ,Evidence-based dentistry ,Health Physics - Abstract
The introduction of cone beam computed tomography (CBCT) technology to dentistry and orthodontics revolutionized the diagnosis, treatment and monitoring of orthodontic patients. This review article discusses the use of CBCT in diagnosis and treatment planning in orthodontics. The steps required to install and operate a CBCT facility within the orthodontic practice as well as the challenges are highlighted. The available guidelines in relation to the clinical applications of CBCT in orthodontics are explored.
- Published
- 2013
18. Scatter correction for quantitative tomographic reconstruction using large area detectors
- Author
-
Rinkel, Jean, Rinkel, Jean, Commissariat à l'énergie atomique et aux énergies alternatives - Laboratoire d'Electronique et de Technologie de l'Information (CEA-LETI), Direction de Recherche Technologique (CEA) (DRT (CEA)), Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Commissariat à l'énergie atomique et aux énergies alternatives (CEA), UNIVERSITE JOSEPH FOURIER, and François ESTEVE
- Subjects
[PHYS]Physics [physics] ,X-ray scattered radiation ,pre-processing ,Cone Beam Computed Tomography ,Tomographie X en Géométrie Conique - Capteur Plan Numérique - Rayonnement Diffusé - Prétraitements ,flat-panel detector ,[PHYS] Physics [physics] - Abstract
Cone Beam Computed Tomography has the advantage of mechanical simplicity in thatfull 3D information can be acquired by a single rotation of the source-detector system andused to obtain isotropic reconstructed volumes. However, detection is performed by a flatpaneldetector and one of the main drawbacks of such detectors is that the amount of scatterreaching them is much higher than that observed in fan beam systems. The scattered radiationinduces artefacts that result in under-estimates of the attenuation coefficients inreconstructed images. The aim of this thesis is to develop data pre-processing and scattercorrection methods to be used in quantitative three-dimensional imaging with a flat-paneldetector and to evaluate these methods in a medical context.The first part of the study describes the experimental bench set-up and defines the protocolused to ensure that data acquisitions are reproducible. Next, pre-processing methodsused to correct the artefacts due to the detector are described. These methods concern thecorrection of defective pixels, image darkness and the spatial non-uniformity of detector response.Original methods are also proposed to correct detector non-linearity and scattering,including X-ray scatter and optical diffusion within the detector. These methods are validatedexperimentally on thorax phantoms.The last part of the study proposes a new method to correct the scattered radiation generatedwithin the examined object. The method is based on an estimation of the scatteredradiation images associated with each tomographic angle of view. Estimation is performedby a calibration of scattering on reference objects combined with analytical modelling of thefirst-order scattering process. This method is validated on thorax phantoms in a configurationof the experimental bench that has no anti-scatter grid. An adaptation of the method usingan anti-scatter grid is also proposed and evaluated experimentally., La tomographie X en géométrie conique permet de réaliser de la tomodensitométrie volumiquepar une simple rotation du système source-détecteur et d’obtenir des volumes reconstruitsà résolution isotrope. Dans une telle géométrie, la détection est réalisée par descapteurs plans numériques. Une des principales limitations de ces derniers est que le rayonnementdiffusé atteignant le capteur est bien plus important que pour les tomographes classiquesà capteurs linéaires ou multibarrettes. Ce rayonnement diffusé crée des artefacts desous-estimations des coefficients d’atténuation sur les images reconstruites. Dans cette thèse,nous proposons des méthodes de prétraitement des données et de correction du diffusé pourréaliser de la tomodensitométrie quantitative avec capteur plan et évaluons expérimentalementces méthodes dans un contexte médical.Une première partie décrit comment mettre en oeuvre un banc de tomographie comportantun capteur plan. A cet effet, un protocole d’acquisition assurant la reproductibilité desacquisitions est défini. Des méthodes de prétraitement numérique des acquisitions corrigeantles artefacts causés par le capteur sont proposées. Outre la correction des pixels défectueux,du niveau d’obscurité et de la non-uniformité de la réponse des différents pixels, des correctionsindispensables à une bonne quantification sont développées. Elles comprennent lacorrection de la non-linéarité de la réponse des pixels et celle d’un signal parasite, appelédiffusé capteur, qui regroupe les phénomènes de diffusion X et optique ayant lieu à l’intérieurdu capteur. Ces méthodes sont validées expérimentalement sur des fantômes représentatifsd’un thorax.Dans une seconde partie, une nouvelle méthode de correction du rayonnement diffusé parl’objet examiné est proposée. Elle est basée sur une estimation des images de rayonnementdiffusé associées à chaque angle de vue tomographique par un calibrage du diffusé généré pardes objets de référence couplé à une modélisation analytique du diffusé du premier ordre.Cette méthode est validée sur des fantômes représentatifs de thorax dans une configurationdu banc expérimental sans grille anti diffusante. Une adaptation de la méthode avec grilleanti diffusante est proposée et évaluée expérimentalement.
- Published
- 2006
19. Analyse rétrospective du repositionnement par CBCT lors d'une radiothérapie d'un carcinome prostatique
- Author
-
Correia, Nicole and Rossier, Jocelyne
- Subjects
Cone Beam Computed Tomography ,Prostate ,Repositionnement ,Déplacements de table ,Image Guided Radiation Therapy ,Radiothérapie ,Cancer - Abstract
INTRODUCTION Le carcinome prostatique touche 30% des hommes suisses. Traités par radiothérapie, les patients doivent être repositionnés de manière précises grâce à l’IGRT afin d’être dans la même position qu’en simulation. OBJECTIFS Notre objectif est d’analyser la fréquence et l’amplitude des déplacements de table quotidiens chez quinze patients et de mettre en évidence d'éventuels écarts entre le début et la fin du traitement. METHODOLOGIE Pour quinze patients traités pour un carcinome prostatique, les déplacements de tables quotidiens sont effectués sur la base d’une acquisition et recalage par CBCT. Ces données ont été récoltées sous forme de rapport de repositionnement. Ces dernières ont été analysées pour chaque axe (AP, SI, GD) et pour chaque patient. RESULTATS La distribution des données suit une loi normale centrée sur 0. Les amplitudes maximales sont -1.6 centimètres et 1.2 centimètres tous axes confondus. La probabilité d'obtenir un déplacement supérieur à 3 millimètres est d'environ 22% en SI, 40% en GD et 50% en AP. Pour ce dernier, il existe une différence significative entre la première et la dernière semaine de traitement. ANALYSE Conformément à la littérature, l'axe AP est le plus susceptible de présenter un déplacement important. Certains patients présentent des différences significatives par rapport à la norme ; celles-ci peuvent être dues aux mouvements du patient ou des effets secondaires par exemple. CONCLUSION Plusieurs résultats intéressants sont ressortis de notre étude tels que des différences entre le début et la fin de traitement, ainsi que l'importance de l'axe AP pour le traitement d'un carcinome prostatique en radiothérapie.
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.