1. Repeatability and agreement in optical biometry of a new swept-source optical coherence tomography–based biometer versus partial coherence interferometry and optical low-coherence reflectometry
- Author
-
Juliane Schütze, Monika Peter, Tobias Buehren, Kathleen S. Kunert, Wolfgang Haigis, Walter Sekundo, and Marcus Blum
- Subjects
Adult ,Male ,medicine.medical_specialty ,Biometry ,Light ,Cataract ,Cornea ,03 medical and health sciences ,0302 clinical medicine ,Optical coherence tomography ,Ophthalmology ,Lens, Crystalline ,medicine ,Humans ,Prospective Studies ,Reflectometry ,Dioptre ,Aged ,Mathematics ,Aged, 80 and over ,medicine.diagnostic_test ,Reproducibility of Results ,Repeatability ,Axial length ,Middle Aged ,Sensory Systems ,Axial Length, Eye ,Interferometry ,Partial coherence interferometry ,030221 ophthalmology & optometry ,Optometry ,Female ,Surgery ,Tomography, Optical Coherence ,030217 neurology & neurosurgery ,Coherence (physics) - Abstract
Purpose To estimate the repeatability of biometric parameters obtained with a new swept-source biometer and to compare the agreement with that of partial coherence interferometry (PCI) and optical low-coherence reflectometry (OLCR). Setting Department of Ophthalmology, Helios Hospital Erfurt, Erfurt, Julius-Maximilians University, Wurzburg, and Philipps University, Marburg, Germany. Design Prospective comparative multicenter clinical study. Methods Biometry was taken with the use of 3 different biometers: the IOLMaster 700 swept-source biometer, the PCI-based IOLMaster 500, and the OCLR-based Lenstar LS 900. Axial length (AL), anterior chamber depth (ACD), and spherical equivalent (SE) were compared between swept-source and PCI biometry and central corneal thickness (CCT) and lens thickness (LT) between swept-source and OLCR biometry. The repeatability of swept-source biometry was evaluated on the basis of 3 measurements captured for each patient. Results One hundred twenty cataract eyes were included in the study. The mean difference between swept-source and PCI biometry for AL, ACD, and SE measurements was 4 μm ± 25 (SD), 17 ± 122 μm, and −0.001 ± 0.19 diopter (D), respectively. The mean difference between swept-source and OLCR biometry for LT and CCT measurements was 21 ± 122 μm and 0.15 ± 4.51 μm, respectively. Differences between swept-source biometry and the other devices distributed around zero without statistical significance. The standard deviation of repeatability for AL, ACD, LT, CCT, and SE was 8.8 μm, 9.8 μm, 2.3 μm, 19.5 μm, and 0.1 D, respectively. Conclusions Swept-source biometry showed high repeatability performance for all biometric parameters. The agreement of AL, ACD, and SE between swept-source and PCI biometry as well as that of LT and CCT between swept-source and OLCR biometry was excellent. It remains to be validated whether high repeatability shown by swept-source biometry will result in better postoperative refractive outcomes. Financial Disclosure Drs. Blum and Sekundo are members of the Scientific Advisory Board of Carl Zeiss Meditec AG. Drs. Peter and Buhren are employees of Carl Zeiss Meditec AG.
- Full Text
- View/download PDF