21 results on '"Fonseca, Gabriel Paiva"'
Search Results
2. Treatment verification in high dose rate brachytherapy using a realistic 3D printed head phantom and an imaging panel
- Author
-
van Wagenberg, Teun, Fonseca, Gabriel Paiva, Voncken, Robert, van Beveren, Celine, van Limbergen, Evert, Lutgens, Ludy, Vanneste, Ben G.L., Berbee, Maaike, Reniers, Brigitte, and Verhaegen, Frank
- Published
- 2023
- Full Text
- View/download PDF
3. 1604: Evaluation of a novel anthropomorphic thorax phantom with a dynamic lung using 4DCT
- Author
-
Lustermans, Didier, Abdulrahim, Roua, Reniers, Brigitte, Verhaegen, Frank, and Fonseca, Gabriel Paiva
- Published
- 2024
- Full Text
- View/download PDF
4. The dosimetric impact of replacing the TG-43 algorithm by model based dose calculation for liver brachytherapy
- Author
-
Duque, Anna Sophie, Corradini, Stefanie, Kamp, Florian, Seidensticker, Max, Streitparth, Florian, Kurz, Christopher, Walter, Franziska, Parodi, Katia, Verhaegen, Frank, Ricke, Jens, Belka, Claus, Fonseca, Gabriel Paiva, and Landry, Guillaume
- Published
- 2020
- Full Text
- View/download PDF
5. A generic TG-186 shielded applicator for commissioning model-based dose calculation algorithms for high-dose-rate 192Ir brachytherapy
- Author
-
Ma, Yunzhi, Vijande, Javier, Ballester, Facundo, Tedgren, Åsa Carlsson, Granero, Domingo, Haworth, Annette, Mourtada, Firas, Fonseca, Gabriel Paiva, Zourari, Kyveli, Papagiannis, Panagiotis, Rivard, Mark J., Siebert, Frank−André, Sloboda, Ron S., Smith, Ryan, Chamberland, Marc J. P., Thomson, Rowan M., Verhaegen, Frank, and Beaulieu, Luc
- Published
- 2017
- Full Text
- View/download PDF
6. Evaluation of novel AI‐based extended field‐of‐view CT reconstructions.
- Author
-
Fonseca, Gabriel Paiva, Baer‐Beck, Matthias, Fournie, Eric, Hofmann, Christian, Rinaldi, Ilaria, Ollers, Michel C, Elmpt, Wouter J.C., and Verhaegen, Frank
- Subjects
- *
COMPUTED tomography , *DEEP learning , *ALGORITHMS , *PHYSICIANS , *IMAGE reconstruction , *IMAGING phantoms , *FLUOROSCOPY , *SCANNING systems - Abstract
Purpose: Modern computed tomography (CT) scanners have an extended field‐of‐view (eFoV) for reconstructing images up to the bore size, which is relevant for patients with higher BMI or non‐isocentric positioning due to fixation devices. However, the accuracy of the image reconstruction in eFoV is not well known since truncated data are used. This study introduces a new deep learning‐based algorithm for extended field‐of‐view reconstruction and evaluates the accuracy of the eFoV reconstruction focusing on aspects relevant for radiotherapy. Methods: A life‐size three‐dimensional (3D) printed thorax phantom, based on a patient CT for which eFoV was necessary, was manufactured and used as reference. The phantom has holes allowing the placement of tissue mimicking inserts used to evaluate the Hounsfield unit (HU) accuracy. CT images of the phantom were acquired using different configurations aiming to evaluate geometric and HU accuracy in the eFoV. Image reconstruction was performed using a state‐of‐the‐art reconstruction algorithm (HDFoV), commercially available, and the novel deep learning‐based approach (HDeepFoV). Five patient cases were selected to evaluate the performance of both algorithms on patient data. There is no ground truth for patients so the reconstructions were qualitatively evaluated by five physicians and five medical physicists. Results: The phantom geometry reconstructed with HDFoV showed boundary deviations from 1.0 to 2.5 cm depending on the volume of the phantom outside the regular scan field of view. HDeepFoV showed a superior performance regardless of the volume of the phantom within eFOV with a maximum boundary deviation below 1.0 cm. The maximum HU (absolute) difference for soft issue inserts is below 79 and 41 HU for HDFoV and HDeepFoV, respectively. HDeepFoV has a maximum deviation of −18 HU for an inhaled lung insert while HDFoV reached a 229 HU difference. The qualitative evaluation of patient cases shows that the novel deep learning approach produces images that look more realistic and have fewer artifacts. Conclusion: To be able to reconstruct images outside the sFoV of the CT scanner there is no alternative than to use some kind of extrapolated data. In our study, we proposed and investigated a new deep learning‐based algorithm and compared it to a commercial solution for eFoV reconstruction. The deep learning‐based algorithm showed superior performance in quantitative evaluations based on phantom data and in qualitative assessments of patient data. [ABSTRACT FROM AUTHOR]
- Published
- 2021
- Full Text
- View/download PDF
7. A Monte Carlo based scatter removal method for non-isocentric cone-beam CT acquisitions using a deep convolutional autoencoder.
- Author
-
van der Heyden, Brent, Uray, Martin, Fonseca, Gabriel Paiva, Huber, Philipp, Us, Defne, Messner, Ivan, Law, Adam, Parii, Anastasiia, Reisz, Niklas, Rinaldi, Ilaria, Freixas, Gloria Vilches, Deutschmann, Heinz, Verhaegen, Frank, and Steininger, Philipp
- Subjects
MONTE Carlo method ,CONE beam computed tomography ,IMAGE reconstruction algorithms ,IMAGE reconstruction ,DIGITAL computer simulation ,ADIPOSE tissues ,SIGNAL-to-noise ratio ,ALGORITHMS - Abstract
The primary cone-beam computed tomography (CBCT) imaging beam scatters inside the patient and produces a contaminating photon fluence that is registered by the detector. Scattered photons cause artifacts in the image reconstruction, and are partially responsible for the inferior image quality compared to diagnostic fan-beam CT. In this work, a deep convolutional autoencoder (DCAE) and projection-based scatter removal algorithm were constructed for the ImagingRing
TM system on rails (IRr), which allows for non-isocentric acquisitions around virtual rotation centers with its independently rotatable source and detector arms. A Monte Carlo model was developed to simulate (i) a non-isocentric training dataset of ≈1200 projection pairs (primary + scatter) from 27 digital head-and-neck cancer patients around five different virtual rotation centers (DCAENONISO ), and (ii) an isocentric dataset existing of ≈1200 projection pairs around the physical rotation center (DCAEISO ). The scatter removal performance of both DCAE networks was investigated in two digital anthropomorphic phantom simulations and due to superior performance only the DCAENONISO was applied on eight real patient acquisitions. Measures for the quantitative error, the signal-to-noise ratio, and the similarity were evaluated for two simulated digital head-and-neck patients, and the contrast-to-noise ratio (CNR) was investigated between muscle and adipose tissue in the real patient image reconstructions. Image quality metrics were compared between the uncorrected data, the currently implemented heuristic scatter correction data, and the DCAE corrected image reconstruction. The DCAENONISO corrected image reconstructions of two digital patient simulations showed superior image quality metrics compared to the uncorrected and corrected image reconstructions using a heuristic scatter removal. The proposed DCAENONISO scatter correction in this study was successfully demonstrated in real non-isocentric patient CBCT acquisitions and achieved statistically significant higher CNRs compared to the uncorrected or the heuristic corrected image data. This paper presents for the first time a projection-based scatter removal algorithm for isocentric and non-isocentric CBCT imaging using a deep convolutional autoencoder trained on Monte Carlo composed datasets. The algorithm was successfully applied to real patient data. [ABSTRACT FROM AUTHOR]- Published
- 2020
- Full Text
- View/download PDF
8. Modelling of the focal spot intensity distribution and the off-focal spot radiation in kilovoltage x-ray tubes for imaging.
- Author
-
van der Heyden, Brent, Fonseca, Gabriel Paiva, Podesta, Mark, Messner, Ivan, Reisz, Niklas, Vaniqui, Ana, Deutschmann, Heinz, Steininger, Phil, and Verhaegen, Frank
- Subjects
- *
X-ray tubes , *X-ray imaging , *RADIATION , *MONTE Carlo method , *PHOTON emission , *CONE beam computed tomography - Abstract
X-ray tubes for medical applications typically generate x-rays by accelerating electrons, emitted from a cathode, with an interelectrode electric field, towards an anode target. X-rays are not emitted from one point, but from an irregularly shaped area on the anode, the focal spot. Focal spot intensity distributions and off-focal radiation negatively affect the imaging spatial resolution and broadens the beam penumbra. In this study, a Monte Carlo simulation model of an x-ray tube was developed to evaluate the spectral and spatial characteristics of off-focal radiation for multiple photon energies. Slit camera measurements were used to determine the horizontal and vertical intensity profiles of the small and the large focal spot of a diagnostic x-ray tube. First, electron beamlet weighting factors were obtained via an iterative optimization method to represent both focal spot sizes. These weighting factors were then used to extract off-focal spot radiation characteristics for the small and large focal spot sizes at 80, 100, and 120 kV. Finally, 120 kV simulations of a steel sphere (d = 4 mm) were performed to investigate image blurring with a point source, the small focal spot, and the large focal spot. The magnitude of off-focal radiation strongly depends on the anode size and the electric field coverage, and only minimally on the tube potential and the primary focal spot size. In conclusion, an x-ray tube Monte Carlo simulation model was developed to simulate focal spot intensity distributions and to evaluate off-focal radiation characteristics at several energies. This model can be further employed to investigate focal spot correction methods and to improve cone-beam CT image quality. [ABSTRACT FROM AUTHOR]
- Published
- 2020
- Full Text
- View/download PDF
9. A generic high-dose rate Ir-192 brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism
- Author
-
Ballester, Facundo, Tedgren, Asa Carlsson, Granero, Domingo, Haworth, Annette, Mourtada, Firas, Fonseca, Gabriel Paiva, Zourari, Kyveli, Papagiannis, Panagiotis, Rivard, Mark J., Siebert, Frank-Andre, Sloboda, Ron S., Smith, Ryan L., Thomson, Rowan M., Verhaegen, Frank, Vijande, Javier, Ma, Yunzhi, Beaulieu, Luc, Promovendi ODB, Radiotherapie, RS: GROW - Oncology, and RS: GROW - R3 - Innovative Cancer Diagnostics & Therapy
- Subjects
HDR brachytherapy ,model-based dose calculation ,TG-186 ,Monte Carlo methods ,Ir-192 - Abstract
Purpose: In order to facilitate a smooth transition for brachytherapy dose calculations from the American Association of Physicists in Medicine (AAPM) Task Group No. 43 (TG-43) formalism to model-based dose calculation algorithms (MBDCAs), treatment planning systems (TPSs) using a MBDCA require a set of well-defined test case plans characterized by Monte Carlo (MC) methods. This also permits direct dose comparison to TG-43 reference data. Such test case plans should be made available for use in the software commissioning process performed by clinical end users. To this end, a hypothetical, generic high-dose rate (HDR) Ir-192 source and a virtual water phantom were designed, which can be imported into a TPS. Methods: A hypothetical, generic HDR Ir-192 source was designed based on commercially available sources as well as a virtual, cubic water phantom that can be imported into any TPS in DICOM format. The dose distribution of the generic Ir-192 source when placed at the center of the cubic phantom, and away from the center under altered scatter conditions, was evaluated using two commercial MBDCAs [Oncentra (R) Brachy with advanced collapsed-cone engine (ACE) and BrachyVision AcuRos (TM)]. Dose comparisons were performed using state-of-the-art MC codes for radiation transport, including ALGEBRA, BrachyDose, GEANT4, MCNP5, MCNP6, and pENELopE2008. The methodologies adhered to recommendations in the AAPM TG-229 report on high-energy brachytherapy source dosimetry. TG-43 dosimetry parameters, an along-away dose-rate table, and primary and scatter separated (PSS) data were obtained. The virtual water phantom of (201)(3) voxels (1 mm sides) was used to evaluate the calculated dose distributions. Two test case plans involving a single position of the generic HDR Ir-192 source in this phantom were prepared: (i) source centered in the phantom and (ii) source displaced 7 cm laterally from the center. Datasets were independently produced by different investigators. MC results were then compared against dose calculated using TG-43 and MBDCA methods. Results: TG-43 and PSS datasets were generated for the generic source, the PSS data for use with the ACE algorithm. The dose-rate constant values obtained from seven MC simulations, performed independently using different codes, were in excellent agreement, yielding an average of 1.1109 +/- 0.0004 cGy/(h U) (k = 1, Type A uncertainty). MC calculated dose-rate distributions for the two plans were also found to be in excellent agreement, with differences within type A uncertainties. Differences between commercial MBDCA and MC results were test, position, and calculation parameter dependent. On average, however, these differences were within 1% for ACUROS and 2% for ACE at clinically relevant distances. Conclusions: A hypothetical, generic HDR Ir-192 source was designed and implemented in two commercially available TPSs employing different MBDCAs. Reference dose distributions for this source were benchmarked and used for the evaluation of MBDCA calculations employing a virtual, cubic water phantom in the form of a CT DICOM image series. The implementation of a generic source of identical design in all TPSs using MBDCAs is an important step toward supporting univocal commissioning procedures and direct comparisons between TPSs.
- Published
- 2015
10. Comparison of TG-43 and TG-186 in breast irradiation using a low energy electronic brachytherapy source
- Author
-
White, Shane A., Landry, Guillaume, Fonseca, Gabriel Paiva, Holt, Randy, Rusch, Thomas, Beaulieu, Luc, Verhaegen, Frank, Reniers, Brigitte, Radiotherapie, Promovendi ODB, RS: GROW - Oncology, and RS: GROW - R3 - Innovative Cancer Diagnostics & Therapy
- Subjects
TG-186 ,electronic brachytherapy ,Monte Carlo dosimetry ,APBI ,tissue modeling ,applicator modeling - Abstract
Purpose: The recently updated guidelines for dosimetry in brachytherapy in TG-186 have recommended the use of model-based dosimetry calculations as a replacement for TG-43. TG-186 highlights shortcomings in the water-based approach in TG-43, particularly for low energy brachytherapy sources. The Xoft Axxent is a low energy (
- Published
- 2014
11. Clinical benefit of range uncertainty reduction in proton treatment planning based on dual‐energy CT for neuro‐oncological patients.
- Author
-
Taasti, Vicki Trier, Decabooter, Esther, Eekers, Daniëlle, Compter, Inge, Rinaldi, Ilaria, Bogowicz, Marta, van der Maas, Tim, Kneepkens, Esther, Schiffelers, Jacqueline, Stultiens, Cissy, Hendrix, Nicole, Pijls, Mirthe, Emmah, Rik, Fonseca, Gabriel Paiva, Unipan, Mirko, and van Elmpt, Wouter
- Subjects
ROBUST optimization ,PROTONS ,PROTON beams ,DUAL energy CT (Tomography) - Abstract
Objective: Several studies have shown that dual‐energy CT (DECT) can lead to improved accuracy for proton range estimation. This study investigated the clinical benefit of reduced range uncertainty, enabled by DECT, in robust optimisation for neuro‐oncological patients. Methods: DECT scans for 27 neuro‐oncological patients were included. Commercial software was applied to create stopping‐power ratio (SPR) maps based on the DECT scan. Two plans were robustly optimised on the SPR map, keeping the beam and plan settings identical to the clinical plan. One plan was robustly optimised and evaluated with a range uncertainty of 3% (as used clinically; denoted 3%‐plan); the second plan applied a range uncertainty of 2% (2%‐plan). Both plans were clinical acceptable and optimal. The dose–volume histogram parameters were compared between the two plans. Two experienced neuro‐radiation oncologists determined the relevant dose difference for each organ‐at‐risk (OAR). Moreover, the OAR toxicity levels were assessed. Results: For 24 patients, a dose reduction >0.5/1 Gy (relevant dose difference depending on the OAR) was seen in one or more OARs for the 2%‐plan; e.g. for brainstem D0.03cc in 10 patients, and hippocampus D40% in 6 patients. Furthermore, 12 patients had a reduction in toxicity level for one or two OARs, showing a clear benefit for the patient. Conclusion: Robust optimisation with reduced range uncertainty allows for reduction of OAR toxicity, providing a rationale for clinical implementation. Based on these results, we have clinically introduced DECT‐based proton treatment planning for neuro‐oncological patients, accompanied with a reduced range uncertainty of 2%. Advances in knowledge: This study shows the clinical benefit of range uncertainty reduction from 3% to 2% in robustly optimised proton plans. A dose reduction to one or more OARs was seen for 89% of the patients, and 44% of the patients had an expected toxicity level decrease. [ABSTRACT FROM AUTHOR]
- Published
- 2023
- Full Text
- View/download PDF
12. A generic TG-186 shielded applicator for commissioning model-based dose calculation algorithms for high-dose-rate 192Ir brachytherapy.
- Author
-
Ma, Yunzhi, Vijande, Javier, Ballester, Facundo, Tedgren, Åsa Carlsson, Granero, Domingo, Haworth, Annette, Mourtada, Firas, Fonseca, Gabriel Paiva, Zourari, Kyveli, Papagiannis, Panagiotis, Rivard, Mark J., Siebert, Frank−André, Sloboda, Ron S., Smith, Ryan, Chamberland, Marc J. P., Thomson, Rowan M., Verhaegen, Frank, and Beaulieu, Luc
- Subjects
HIGH dose rate brachytherapy ,RADIATION doses ,RADIATION shielding ,MONTE Carlo method ,IMAGING phantoms - Abstract
Purpose A joint working group was created by the American Association of Physicists in Medicine (AAPM), the European Society for Radiotherapy and Oncology (ESTRO), and the Australasian Brachytherapy Group (ABG) with the charge, among others, to develop a set of well-defined test case plans and perform calculations and comparisons with model-based dose calculation algorithms (MBDCAs). Its main goal is to facilitate a smooth transition from the AAPM Task Group No. 43 (TG-43) dose calculation formalism, widely being used in clinical practice for brachytherapy, to the one proposed by Task Group No. 186 (TG-186) for MBDCAs. To do so, in this work a hypothetical, generic high-dose rate (HDR)
192 Ir shielded applicator has been designed and benchmarked. Methods A generic HDR192 Ir shielded applicator was designed based on three commercially available gynecological applicators as well as a virtual cubic water phantom that can be imported into any DICOM-RT compatible treatment planning system (TPS). The absorbed dose distribution around the applicator with the TG-186192 Ir source located at one dwell position at its center was computed using two commercial TPSs incorporating MBDCAs (Oncentra® Brachy with Advanced Collapsed-cone Engine, ACE™, and BrachyVision ACUROS™) and state-of-the-art Monte Carlo (MC) codes, including ALGEBRA, BrachyDose, egs_brachy, Geant4, MCNP6, and Penelope2008. TPS-based volumetric dose distributions for the previously reported 'source centered in water' and 'source displaced' test cases, and the new 'source centered in applicator' test case, were analyzed here using the MCNP6 dose distribution as a reference. Volumetric dose comparisons of TPS results against results for the other MC codes were also performed. Distributions of local and global dose difference ratios are reported. Results The local dose differences among MC codes are comparable to the statistical uncertainties of the reference datasets for the 'source centered in water' and 'source displaced' test cases and for the clinically relevant part of the unshielded volume in the 'source centered in applicator' case. Larger local differences appear in the shielded volume or at large distances. Considering clinically relevant regions, global dose differences are smaller than the local ones. The most disadvantageous case for the MBDCAs is the one including the shielded applicator. In this case, ACUROS agrees with MC within [−4.2%, +4.2%] for the majority of voxels (95%) while presenting dose differences within [−0.12%, +0.12%] of the dose at a clinically relevant reference point. For ACE, 95% of the total volume presents differences with respect to MC in the range [−1.7%, +0.4%] of the dose at the reference point. Conclusions The combination of the generic source and generic shielded applicator, together with the previously developed test cases and reference datasets (available in the Brachytherapy Source Registry), lay a solid foundation in supporting uniform commissioning procedures and direct comparisons among treatment planning systems for HDR192 Ir brachytherapy. [ABSTRACT FROM AUTHOR]- Published
- 2017
- Full Text
- View/download PDF
13. A generic high-dose rate 192Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism.
- Author
-
Ballester, Facundo, Carlsson Tedgren, Åsa, Granero, Domingo, Haworth, Annette, Mourtada, Firas, Fonseca, Gabriel Paiva, Zourari, Kyveli, Papagiannis, Panagiotis, Rivard, Mark J., Siebert, Frank‐André, Sloboda, Ron S., Smith, Ryan L., Thomson, Rowan M., Verhaegen, Frank, Vijande, Javier, Ma, Yunzhi, and Beaulieu, Luc
- Subjects
RADIOISOTOPE brachytherapy ,IRIDIUM isotopes ,RADIATION doses ,RADIOTHERAPY treatment planning ,CLINICAL trials - Abstract
Purpose: In order to facilitate a smooth transition for brachytherapy dose calculations from the American Association of Physicists in Medicine (AAPM) Task Group No. 43 (TG-43) formalism to model-based dose calculation algorithms (MBDCAs), treatment planning systems (TPSs) using a MBDCA require a set of well-defined test case plans characterized by Monte Carlo (MC) methods. This also permits direct dose comparison to TG-43 reference data. Such test case plans should be made available for use in the software commissioning process performed by clinical end users. To this end, a hypothetical, generic high-dose rate (HDR)
192 Ir source and a virtual water phantom were designed, which can be imported into a TPS. Methods: A hypothetical, generic HDR192 Ir source was designed based on commercially available sources as well as a virtual, cubic water phantom that can be imported into any TPS in DICOM format. The dose distribution of the generic192 Ir source when placed at the center of the cubic phantom, and away from the center under altered scatter conditions, was evaluated using two commercial MBDCAs [Oncentra® Brachy with advanced collapsed-cone engine (ACE) and BrachyVision ACUROS™ ]. Dose comparisons were performed using state-of-the-art MC codes for radiation transport, including ALGEBRA, BrachyDose, GEANT4, MCNP5, MCNP6, and PENELOPE2008. The methodologies adhered to recommendations in the AAPM TG-229 report on high-energy brachytherapy source dosimetry. TG-43 dosimetry parameters, an along-away dose-rate table, and primary and scatter separated (PSS) data were obtained. The virtual water phantom of (201)³ voxels (1 mm sides) was used to evaluate the calculated dose distributions. Two test case plans involving a single position of the generic HDR192 Ir source in this phantom were prepared: (i) source centered in the phantom and (ii) source displaced 7 cm laterally from the center. Datasets were independently produced by different investigators. MC results were then compared against dose calculated using TG-43 and MBDCA methods. Results: TG-43 and PSS datasets were generated for the generic source, the PSS data for use with theACE algorithm. The dose-rate constant values obtained from seven MC simulations, performed independently using different codes, were in excellent agreement, yielding an average of 1.1109±0.0004 cGy/(h U) (k = 1, Type A uncertainty). MC calculated dose-rate distributions for the two plans were also found to be in excellent agreement, with differences within type A uncertainties. Differences between commercial MBDCA and MC results were test, position, and calculation parameter dependent. On average, however, these differences were within 1% for ACUROS and 2% for ACE at clinically relevant distances. Conclusions: A hypothetical, generic HDR192 Ir source was designed and implemented in two commercially available TPSs employing different MBDCAs. Reference dose distributions for this source were benchmarked and used for the evaluation of MBDCA calculations employing a virtual, cubic water phantom in the form of a CT DICOM image series. The implementation of a generic source of identical design in all TPSs using MBDCAs is an important step toward supporting univocal commissioning procedures and direct comparisons between TPSs. [ABSTRACT FROM AUTHOR]- Published
- 2015
- Full Text
- View/download PDF
14. Treatment verification in high dose rate brachytherapy using a realistic 3D printed head phantom and an imaging panel
- Author
-
Teun van Wagenberg, Gabriel Paiva Fonseca, Robert Voncken, Celine van Beveren, Evert van Limbergen, Ludy Lutgens, Ben G.L. Vanneste, Maaike Berbee, Brigitte Reniers, Frank Verhaegen, verhaegen, frank/0000-0001-8470-386X, RENIERS, Brigitte/0000-0001-7084-4696, van Wagenberg, Teun/0000-0002-5642-510X, Vanneste, Ben/0000-0003-2334-5207, Celine/0000-0002-3434-8537, van Wagenberg, Teun, Fonseca, Gabriel Paiva, Voncken, Robert, van Beveren, Celine, van Limbergen, Evert, Lutgens, Ludy, Vanneste, Ben G. L., Berbee, Maaike, RENIERS, Brigitte, Verhaegen, Frank, Radiotherapie, RS: GROW - R2 - Basic and Translational Cancer Biology, MUMC+: MA Radiotherapie OC (3), MUMC+: MA Radiotherapie OC (9), RS: GROW - R3 - Innovative Cancer Diagnostics & Therapy, and Maastro clinic
- Subjects
Error detection ,High dose rate brachytherapy ,Oncology ,In vivo dosimetry ,Dose recalculation ,Radiology, Nuclear Medicine and imaging ,Treatment verification - Abstract
PURPOSE: Even though High Dose Rate (HDR) brachytherapy has good treatment outcomes in different treatment sites, treatment verification is far from widely implemented because of a lack of easily available solutions. Previously it has been shown that an imaging panel (IP) near the patient can be used to determine treatment parameters such as the dwell time and source positions in a single material pelvic phantom. In this study we will use a heterogeneous head phantom to test this IP approach, and simulate common treatment errors to assess the sensitivity and specificity of the error-detecting capabilities of the IP. METHODS AND MATERIALS: A heterogeneous head-phantom consisting of soft tissue and bone equivalent materials was 3D-printed to simulate a base of tongue treatment. An High Dose Rate treatment plan with 3 different catheters was used to simulate a treatment delivery, using dwell times ranging from 0.3 s to 4 s and inter-dwell distances of 2 mm. The IP was used to measure dwell times, positions and detect simulated errors. Measured dwell times and positions were used to calculate the delivered dose. RESULTS: Dwell times could be determined within 0.1 s. Source positions were measured with submillimeter accuracy in the plane of the IP, and average distance accuracy of 1.7 mm in three dimensions. All simulated treatment errors (catheter swap, catheter shift, afterloader errors) were detected. Dose calculations show slightly different distributions with the measured dwell positions and dwell times (gamma pass rate for 1 mm/1% of 96.5%). CONCLUSIONS: Using an IP, it was possible to verify the treatment in a real-istic heterogeneous phantom and detect certain treatment errors. (c) 2022 The Au-thors. Published by Elsevier Inc. on behalf of American Brachytherapy Society. This is an open access article under the CC BY license ( http://creativecommons.org/licenses/by/4.0/ ) We thank Dr. Murillo Bellezzo for his help with the measurements, and Dr. Mark Podesta for his helpful Matlab functions.
- Published
- 2023
15. Image quality evaluation of a new high-performance ring-gantry cone-beam computed tomography imager.
- Author
-
Lustermans D, Fonseca GP, Taasti VT, van de Schoot A, Petit S, van Elmpt W, and Verhaegen F
- Subjects
- Humans, Artifacts, Quality Control, Cone-Beam Computed Tomography instrumentation, Cone-Beam Computed Tomography methods, Phantoms, Imaging, Image Processing, Computer-Assisted methods
- Abstract
Objective . Newer cone-beam computed tomography (CBCT) imaging systems offer reconstruction algorithms including metal artifact reduction (MAR) and extended field-of-view (eFoV) techniques to improve image quality. In this study a new CBCT imager, the new Varian HyperSight CBCT, is compared to fan-beam CT and two CBCT imagers installed in a ring-gantry and C-arm linear accelerator, respectively. Approach . The image quality was assessed for HyperSight CBCT which uses new hardware, including a large-size flat panel detector, and improved image reconstruction algorithms. The decrease of metal artifacts was quantified (structural similarity index measure (SSIM) and root-mean-squared error (RMSE)) when applying MAR reconstruction and iterative reconstruction for a dental and spine region using a head-and-neck phantom. The geometry and CT number accuracy of the eFoV reconstruction was evaluated outside the standard field-of-view (sFoV) on a large 3D-printed chest phantom. Phantom size dependency of CT numbers was evaluated on three cylindrical phantoms of increasing diameter. Signal-to-noise and contrast-to-noise were quantified on an abdominal phantom. Main results . In phantoms with streak artifacts, MAR showed comparable results for HyperSight CBCT and CT, with MAR increasing the SSIM (0.97-0.99) and decreasing the RMSE (62-55 HU) compared to iterative reconstruction without MAR. In addition, HyperSight CBCT showed better geometrical accuracy in the eFoV than CT (Jaccard Conformity Index increase of 0.02-0.03). However, the CT number accuracy outside the sFoV was lower than for CT. The maximum CT number variation between different phantom sizes was lower for the HyperSight CBCT imager (∼100 HU) compared to the two other CBCT imagers (∼200 HU), but not fully comparable to CT (∼50 HU). Significance . This study demonstrated the imaging performance of the new HyperSight CBCT imager and the potential of applying this CBCT system in more advanced scenarios by comparing the quality against fan-beam CT., (Creative Commons Attribution license.)
- Published
- 2024
- Full Text
- View/download PDF
16. A generic TG-186 shielded applicator for commissioning model-based dose calculation algorithms for high-dose-rate 192 Ir brachytherapy.
- Author
-
Ma Y, Vijande J, Ballester F, Tedgren ÅC, Granero D, Haworth A, Mourtada F, Fonseca GP, Zourari K, Papagiannis P, Rivard MJ, Siebert FA, Sloboda RS, Smith R, Chamberland MJP, Thomson RM, Verhaegen F, and Beaulieu L
- Subjects
- Humans, Phantoms, Imaging, Radiotherapy Dosage, Radiotherapy Planning, Computer-Assisted, Algorithms, Brachytherapy methods, Iridium Radioisotopes therapeutic use, Monte Carlo Method, Radiation Dosage
- Abstract
Purpose: A joint working group was created by the American Association of Physicists in Medicine (AAPM), the European Society for Radiotherapy and Oncology (ESTRO), and the Australasian Brachytherapy Group (ABG) with the charge, among others, to develop a set of well-defined test case plans and perform calculations and comparisons with model-based dose calculation algorithms (MBDCAs). Its main goal is to facilitate a smooth transition from the AAPM Task Group No. 43 (TG-43) dose calculation formalism, widely being used in clinical practice for brachytherapy, to the one proposed by Task Group No. 186 (TG-186) for MBDCAs. To do so, in this work a hypothetical, generic high-dose rate (HDR)
192 Ir shielded applicator has been designed and benchmarked., Methods: A generic HDR192 Ir shielded applicator was designed based on three commercially available gynecological applicators as well as a virtual cubic water phantom that can be imported into any DICOM-RT compatible treatment planning system (TPS). The absorbed dose distribution around the applicator with the TG-186192 Ir source located at one dwell position at its center was computed using two commercial TPSs incorporating MBDCAs (Oncentra® Brachy with Advanced Collapsed-cone Engine, ACE™, and BrachyVision ACUROS™) and state-of-the-art Monte Carlo (MC) codes, including ALGEBRA, BrachyDose, egs_brachy, Geant4, MCNP6, and Penelope2008. TPS-based volumetric dose distributions for the previously reported "source centered in water" and "source displaced" test cases, and the new "source centered in applicator" test case, were analyzed here using the MCNP6 dose distribution as a reference. Volumetric dose comparisons of TPS results against results for the other MC codes were also performed. Distributions of local and global dose difference ratios are reported., Results: The local dose differences among MC codes are comparable to the statistical uncertainties of the reference datasets for the "source centered in water" and "source displaced" test cases and for the clinically relevant part of the unshielded volume in the "source centered in applicator" case. Larger local differences appear in the shielded volume or at large distances. Considering clinically relevant regions, global dose differences are smaller than the local ones. The most disadvantageous case for the MBDCAs is the one including the shielded applicator. In this case, ACUROS agrees with MC within [-4.2%, +4.2%] for the majority of voxels (95%) while presenting dose differences within [-0.12%, +0.12%] of the dose at a clinically relevant reference point. For ACE, 95% of the total volume presents differences with respect to MC in the range [-1.7%, +0.4%] of the dose at the reference point., Conclusions: The combination of the generic source and generic shielded applicator, together with the previously developed test cases and reference datasets (available in the Brachytherapy Source Registry), lay a solid foundation in supporting uniform commissioning procedures and direct comparisons among treatment planning systems for HDR192 Ir brachytherapy., (© 2017 American Association of Physicists in Medicine.)- Published
- 2017
- Full Text
- View/download PDF
17. Monte Carlo studies on water and LiF cavity properties for dose-reporting quantities when using x-ray and brachytherapy sources.
- Author
-
Branco IS, Antunes PC, Fonseca GP, and Yoriyaz H
- Subjects
- Algorithms, Humans, Phantoms, Imaging, Photons, Radiotherapy Dosage, X-Rays, Brachytherapy, Monte Carlo Method, Radiation Dosage, Radiotherapy Planning, Computer-Assisted methods, Water
- Abstract
Model-based dose calculation algorithms (MBDCAs) are the current tools to estimate dose in brachytherapy, which takes into account heterogeneous medium, therefore, departing from water-based formalism (TG-43). One aspect associated to MBCDA is the choice of dose specification medium since it offers two possibilities to report dose: (a) dose to medium in medium, D
m,m ; and (b) dose to water in medium, Dw,m . The discussion about the preferable quantity to be reported is underway. The dose conversion factors, DCF, between dose to water in medium, Dw,m , and dose to medium in medium, Dm,m , is based on cavity theory and can be obtained using different approaches. When experimental dose verification is desired using, for example, thermoluminescent LiF dosimeters, as in in vivo dose measurements, a third quantity is obtained, which is the dose to LiF in medium, DLiF,m . In this case, DCF to convert from DLiF,m to Dw,m or Dm,m is necessary. The objective of this study is to estimate DCFs using different approaches, present in the literature, quantifying the differences between them. Also, dose in water and LiF cavities in different tissue media and respective conversion factors to be able to convert LiF-based dose measured values into dose in water or tissue were obtained. Simple cylindrical phantoms composed by different tissue equivalent materials (bone, lung, water and adipose) are modelled. The phantoms contain a radiation source and a cavity with 0.002 69 cm3 in size, which is a typical volume of a disc type LiF dosimeter. Three x-rays qualities with average energies ranging from 47 to 250 keV, and three brachytherapy sources,60 Co,192 Ir and137 Cs, are considered. Different cavity theory approaches for DCF calculations and different cavity/medium combinations have been considered in this study. DCF values for water/bone and LiF/bone cases have strong dependence with energy increasing as the photon energy increases. DCF values also increase with energy for LiF/lung and water/lung cases but, they are much less dependent of energy. For LiF/adipose, water/adipose and LiF/water cases, the DCF values are also dependent of photon energy but, decreases as the energy increases. Maximum difference of 12% has been found compared to values in literature.- Published
- 2016
- Full Text
- View/download PDF
18. Dose specification for ¹⁹²Ir high dose rate brachytherapy in terms of dose-to-water-in-medium and dose-to-medium-in-medium.
- Author
-
Fonseca GP, Tedgren ÅC, Reniers B, Nilsson J, Persson M, Yoriyaz H, and Verhaegen F
- Subjects
- Radiation Monitoring standards, Radiotherapy Dosage, Water chemistry, Algorithms, Brachytherapy methods, Iridium Radioisotopes therapeutic use, Radiation Monitoring methods, Radiopharmaceuticals therapeutic use, Radiotherapy Planning, Computer-Assisted methods
- Abstract
Dose calculation in high dose rate brachytherapy with (192)Ir is usually based on the TG-43U1 protocol where all media are considered to be water. Several dose calculation algorithms have been developed that are capable of handling heterogeneities with two possibilities to report dose: dose-to-medium-in-medium (Dm,m) and dose-to-water-in-medium (Dw,m). The relation between Dm,m and Dw,m for (192)Ir is the main goal of this study, in particular the dependence of Dw,m on the dose calculation approach using either large cavity theory (LCT) or small cavity theory (SCT). A head and neck case was selected due to the presence of media with a large range of atomic numbers relevant to tissues and mass densities such as air, soft tissues and bone interfaces. This case was simulated using a Monte Carlo (MC) code to score: Dm,m, Dw,m (LCT), mean photon energy and photon fluence. Dw,m (SCT) was derived from MC simulations using the ratio between the unrestricted collisional stopping power of the actual medium and water. Differences between Dm,m and Dw,m (SCT or LCT) can be negligible (<1%) for some tissues e.g. muscle and significant for other tissues with differences of up to 14% for bone. Using SCT or LCT approaches leads to differences between Dw,m (SCT) and Dw,m (LCT) up to 29% for bone and 36% for teeth. The mean photon energy distribution ranges from 222 keV up to 356 keV. However, results obtained using mean photon energies are not equivalent to the ones obtained using the full, local photon spectrum. This work concludes that it is essential that brachytherapy studies clearly report the dose quantity. It further shows that while differences between Dm,m and Dw,m (SCT) mainly depend on tissue type, differences between Dm,m and Dw,m (LCT) are, in addition, significantly dependent on the local photon energy fluence spectrum which varies with distance to implanted sources.
- Published
- 2015
- Full Text
- View/download PDF
19. A generic high-dose rate (192)Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism.
- Author
-
Ballester F, Carlsson Tedgren Å, Granero D, Haworth A, Mourtada F, Fonseca GP, Zourari K, Papagiannis P, Rivard MJ, Siebert FA, Sloboda RS, Smith RL, Thomson RM, Verhaegen F, Vijande J, Ma Y, and Beaulieu L
- Subjects
- Algorithms, Humans, Phantoms, Imaging, Radiotherapy Dosage, Water, Brachytherapy methods, Iridium Radioisotopes therapeutic use, Monte Carlo Method, Radiation Dosage, Radiotherapy Planning, Computer-Assisted methods
- Abstract
Purpose: In order to facilitate a smooth transition for brachytherapy dose calculations from the American Association of Physicists in Medicine (AAPM) Task Group No. 43 (TG-43) formalism to model-based dose calculation algorithms (MBDCAs), treatment planning systems (TPSs) using a MBDCA require a set of well-defined test case plans characterized by Monte Carlo (MC) methods. This also permits direct dose comparison to TG-43 reference data. Such test case plans should be made available for use in the software commissioning process performed by clinical end users. To this end, a hypothetical, generic high-dose rate (HDR) (192)Ir source and a virtual water phantom were designed, which can be imported into a TPS., Methods: A hypothetical, generic HDR (192)Ir source was designed based on commercially available sources as well as a virtual, cubic water phantom that can be imported into any TPS in DICOM format. The dose distribution of the generic (192)Ir source when placed at the center of the cubic phantom, and away from the center under altered scatter conditions, was evaluated using two commercial MBDCAs [Oncentra(®) Brachy with advanced collapsed-cone engine (ACE) and BrachyVision ACUROS™ ]. Dose comparisons were performed using state-of-the-art MC codes for radiation transport, including ALGEBRA, BrachyDose, GEANT4, MCNP5, MCNP6, and PENELOPE2008. The methodologies adhered to recommendations in the AAPM TG-229 report on high-energy brachytherapy source dosimetry. TG-43 dosimetry parameters, an along-away dose-rate table, and primary and scatter separated (PSS) data were obtained. The virtual water phantom of (201)(3) voxels (1 mm sides) was used to evaluate the calculated dose distributions. Two test case plans involving a single position of the generic HDR (192)Ir source in this phantom were prepared: (i) source centered in the phantom and (ii) source displaced 7 cm laterally from the center. Datasets were independently produced by different investigators. MC results were then compared against dose calculated using TG-43 and MBDCA methods., Results: TG-43 and PSS datasets were generated for the generic source, the PSS data for use with the ace algorithm. The dose-rate constant values obtained from seven MC simulations, performed independently using different codes, were in excellent agreement, yielding an average of 1.1109 ± 0.0004 cGy/(h U) (k = 1, Type A uncertainty). MC calculated dose-rate distributions for the two plans were also found to be in excellent agreement, with differences within type A uncertainties. Differences between commercial MBDCA and MC results were test, position, and calculation parameter dependent. On average, however, these differences were within 1% for ACUROS and 2% for ace at clinically relevant distances., Conclusions: A hypothetical, generic HDR (192)Ir source was designed and implemented in two commercially available TPSs employing different MBDCAs. Reference dose distributions for this source were benchmarked and used for the evaluation of MBDCA calculations employing a virtual, cubic water phantom in the form of a CT DICOM image series. The implementation of a generic source of identical design in all TPSs using MBDCAs is an important step toward supporting univocal commissioning procedures and direct comparisons between TPSs.
- Published
- 2015
- Full Text
- View/download PDF
20. The use of tetrahedral mesh geometries in Monte Carlo simulation of applicator based brachytherapy dose distributions.
- Author
-
Fonseca GP, Landry G, White S, D'Amours M, Yoriyaz H, Beaulieu L, Reniers B, and Verhaegen F
- Subjects
- Algorithms, Brachytherapy methods, Breast Neoplasms pathology, Computer Simulation, Female, Humans, Models, Biological, Radiation Protection, Radiotherapy Dosage, Brachytherapy instrumentation, Breast Neoplasms radiotherapy, Monte Carlo Method, Phantoms, Imaging, Prostheses and Implants, Radiotherapy Planning, Computer-Assisted methods
- Abstract
Accounting for brachytherapy applicator attenuation is part of the recommendations from the recent report of AAPM Task Group 186. To do so, model based dose calculation algorithms require accurate modelling of the applicator geometry. This can be non-trivial in the case of irregularly shaped applicators such as the Fletcher Williamson gynaecological applicator or balloon applicators with possibly irregular shapes employed in accelerated partial breast irradiation (APBI) performed using electronic brachytherapy sources (EBS). While many of these applicators can be modelled using constructive solid geometry (CSG), the latter may be difficult and time-consuming. Alternatively, these complex geometries can be modelled using tessellated geometries such as tetrahedral meshes (mesh geometries (MG)). Recent versions of Monte Carlo (MC) codes Geant4 and MCNP6 allow for the use of MG. The goal of this work was to model a series of applicators relevant to brachytherapy using MG. Applicators designed for (192)Ir sources and 50 kV EBS were studied; a shielded vaginal applicator, a shielded Fletcher Williamson applicator and an APBI balloon applicator. All applicators were modelled in Geant4 and MCNP6 using MG and CSG for dose calculations. CSG derived dose distributions were considered as reference and used to validate MG models by comparing dose distribution ratios. In general agreement within 1% for the dose calculations was observed for all applicators between MG and CSG and between codes when considering volumes inside the 25% isodose surface. When compared to CSG, MG required longer computation times by a factor of at least 2 for MC simulations using the same code. MCNP6 calculation times were more than ten times shorter than Geant4 in some cases. In conclusion we presented methods allowing for high fidelity modelling with results equivalent to CSG. To the best of our knowledge MG offers the most accurate representation of an irregular APBI balloon applicator.
- Published
- 2014
- Full Text
- View/download PDF
21. Comparison of TG-43 and TG-186 in breast irradiation using a low energy electronic brachytherapy source.
- Author
-
White SA, Landry G, Fonseca GP, Holt R, Rusch T, Beaulieu L, Verhaegen F, and Reniers B
- Subjects
- Air, Breast radiation effects, Breast Neoplasms diagnostic imaging, Computer Simulation, Humans, Mammography, Models, Biological, Monte Carlo Method, Radiotherapy Dosage, Skin radiation effects, Tomography, X-Ray Computed, Water, Brachytherapy instrumentation, Brachytherapy methods, Breast Neoplasms radiotherapy, Radiotherapy Planning, Computer-Assisted methods
- Abstract
Purpose: The recently updated guidelines for dosimetry in brachytherapy in TG-186 have recommended the use of model-based dosimetry calculations as a replacement for TG-43. TG-186 highlights shortcomings in the water-based approach in TG-43, particularly for low energy brachytherapy sources. The Xoft Axxent is a low energy (<50 kV) brachytherapy system used in accelerated partial breast irradiation (APBI). Breast tissue is a heterogeneous tissue in terms of density and composition. Dosimetric calculations of seven APBI patients treated with Axxent were made using a model-based Monte Carlo platform for a number of tissue models and dose reporting methods and compared to TG-43 based plans., Methods: A model of the Axxent source, the S700, was created and validated against experimental data. CT scans of the patients were used to create realistic multi-tissue/heterogeneous models with breast tissue segmented using a published technique. Alternative water models were used to isolate the influence of tissue heterogeneity and backscatter on the dose distribution. Dose calculations were performed using Geant4 according to the original treatment parameters. The effect of the Axxent balloon applicator used in APBI which could not be modeled in the CT-based model, was modeled using a novel technique that utilizes CAD-based geometries. These techniques were validated experimentally. Results were calculated using two dose reporting methods, dose to water (Dw,m) and dose to medium (Dm,m), for the heterogeneous simulations. All results were compared against TG-43-based dose distributions and evaluated using dose ratio maps and DVH metrics. Changes in skin and PTV dose were highlighted., Results: All simulated heterogeneous models showed a reduced dose to the DVH metrics that is dependent on the method of dose reporting and patient geometry. Based on a prescription dose of 34 Gy, the average D90 to PTV was reduced by between ~4% and ~40%, depending on the scoring method, compared to the TG-43 result. Peak skin dose is also reduced by 10%-15% due to the absence of backscatter not accounted for in TG-43. The balloon applicator also contributed to the reduced dose. Other ROIs showed a difference depending on the method of dose reporting., Conclusions: TG-186-based calculations produce results that are different from TG-43 for the Axxent source. The differences depend strongly on the method of dose reporting. This study highlights the importance of backscatter to peak skin dose. Tissue heterogeneities, applicator, and patient geometries demonstrate the need for a more robust dose calculation method for low energy brachytherapy sources.
- Published
- 2014
- Full Text
- View/download PDF