1. Comparison of intraocular lens tilt after capsular sutured scleral fixation with capsular segments versus uneventful cataract surgery.
- Author
-
Chang-Sotomayor M, Gϋell JL, de Rojas Silva MV, Corretger X, Bandeira F, Mendez-Mourelle A, Veillet LZ, Adán A, and Figueras-Roca M
- Subjects
- Humans, Retrospective Studies, Female, Aged, Male, Biometry, Visual Acuity physiology, Refraction, Ocular physiology, Middle Aged, Aged, 80 and over, Phacoemulsification, Lens Implantation, Intraocular methods, Sclera surgery, Lenses, Intraocular, Lens Capsule, Crystalline surgery, Suture Techniques, Artificial Lens Implant Migration physiopathology, Artificial Lens Implant Migration etiology
- Abstract
Purpose: To evaluate and compare intraocular lens (IOL) tilt between uneventful phacoemulsification with in-the-bag IOL implantation and sutured scleral fixation (SSF) of the lens bag with a capsular tension segment (type 6 D / Morcher) using a Sheimpflug camera., Setting: Clinical Practice, Hospital. Barcelona and A Coruña, Spain., Design: Retrospective, comparative multicenter study., Methods: IOL tilt was compared between patients who underwent sutured scleral fixation with a capsular tension segment in a single eye (SSF group, n = 15) with patients who underwent uneventful IOL implantation (control group, n = 12) that were matched by biometric measurements. Post-operative refractive accuracy of biometric formulas by means of mean absolute error (MAE) was also reported. All patients underwent a general ophthalmic evaluation, anterior segment photography, and postoperative optical biometry (Zeiss IOLMaster® 500). In addition, IOL tilt was measured with a Scheimpflug camera (Pentacam R, Oculus Optikgerate Gmbh)., Results: Mean vertical tilt was similar in both groups (2.20+/-2.47° SSF vs 1.97 +/- 1.79° control; p = 0.836) but mean horizontal tilt tended to higher values in the SSF series (2.09 +/- 2.74° vs 0.94 +/- 1.17°; p = 0.139). Considering post-operative refractive error in diopters by MAE calculations, there was an underestimation of IOL power in the SSF group which was only statistically significant for Barrett Universal II (1.07 vs 0.32; p = 0.028) and Hill-RBF (0.95 vs 0.26; p = 0.024) formulas, but not for SRK/T (0.99 vs 0.42; p = 0.285) and Kane (0.96 vs 0.33; p = 0.083)., Conclusion: Sutured scleral fixation of capsular tension segments in the presence of zonular instability does not seem to induce clinically significant IOL tilt compared to uneventful cataract extraction cases., Competing Interests: Declaration of conflicting interestsThe author(s) declared no potential conflicts of interest with respect to the research, authorship, and/or publication of this article.
- Published
- 2024
- Full Text
- View/download PDF