4 results on '"Hong-Kui Yu"'
Search Results
2. Pelvic Ultrasound in Diagnosing and Evaluating the Efficacy of Gonadotropin-Releasing Hormone Agonist Therapy in Girls With Idiopathic Central Precocious Puberty
- Author
-
Hong-kui Yu, Xiao Liu, Jia-kun Chen, Shan Wang, and Xian-yue Quan
- Subjects
ultrasonography ,uterus ,ovary ,isosexual precocity ,sexual characteristics ,Therapeutics. Pharmacology ,RM1-950 - Abstract
Background and Objective: Idiopathic central precocious puberty (ICPP) is characterized by early pubertal changes, the acceleration of growth velocity, and rapid bone maturation that often results in reduced adult height. Gonadotrophin-releasing hormone agonist (GnRHa) is currently considered to be an effective therapeutic agent. At present, GnRH stimulation test is adopted as a gold standard for the diagnosis of ICPP and the efficacy evaluation of GnRHa therapy. However, it is difficult to operate in practice due to the cumbersome procedures and multiple blood samples required. This study was conducted to establish the value of pelvic ultrasound in diagnosing ICPP and evaluating the efficacy of GnRHa therapy.Materials and Methods: One hundred and twenty-two girls with ICPP (ICPP group) were enrolled in the study. Pelvic ultrasound and levels of luteinizing hormone (LH) and follicle-stimulating hormone (FSH) were examined before and after GnRHa therapy for 3 months. Eighty normal prepubertal girls were enrolled as the control group. The difference in pelvic ultrasound parameters between the ICPP group before GnRHa therapy and the control group was compared by independent-sample t-test, while paired t-test for ICPP group before and after GnRHa therapy. Receiver operating characteristic (ROC) curve was used to explore the optimal pelvic ultrasound parameters for diagnosing ICPP. Pearson correlation analysis was performed between the pelvic ultrasound parameters and serum sexual hormone level.Results: The pelvic ultrasound parameters (length of the uterine body, anteroposterior diameter of the uterine body, transverse diameter of the uterine body, volume of the uterine body, uterine body-cervix ratio, length of the ovary, transverse diameter of the ovary, anteroposterior diameter of the ovary, volume of the ovary, number of increased follicles and maximum diameter of the follicle) in the ICPP group before GnRHa therapy were significantly larger than those of the control group (P < 0.05). All the above pelvic ultrasound parameters in the ICPP group were significantly decreased after GnRHa therapy compared with those before treatment (P < 0.05). The volume of the uterine body had the largest area under the ROC curve in differentiating between patients with ICCP and the control group. Pelvic ultrasound parameters were significantly correlated with serum sexual hormone levels (P < 0.05).Conclusion: This study indicates pelvic ultrasound is a simple and reliable tool to diagnose ICPP and evaluates the efficacy of GnRHa therapy by dynamically observing the morphology of internal genitalia. The volume of uterine body was the best ultrasound parameter to distinguish patients with ICPP from normal girls.
- Published
- 2019
- Full Text
- View/download PDF
3. Atropine Premedication Facilitates Ultrasound-Guided Reduction by Saline Enema in Children With Intussusception
- Author
-
Xiao Liu, Bei Xia, Hong-kui Yu, Lie-zhen Hu, Shu-min Fan, Dong Xiao, Li-xian Gu, Jia-kun Chen, Zhi-bo Wen, and Xiao-peng Ma
- Subjects
intussusception ,atropine ,enema ,ultrasound ,children ,Therapeutics. Pharmacology ,RM1-950 - Abstract
Background and Objective: Intussusception is the most frequent pediatric abdominal emergency. Intestinal spasm, ischemia, necrosis and even death may occur without prompt diagnosis and treatment. The ultrasound-guided reduction by saline enema is a preferred non-surgical procedure for intussusception. Muscular relaxants can relieve the intestinal spasm and edema by relaxing the intestinal smooth muscle, which may facilitate the treatment of intussusception. However, controversy persists on whether muscular relaxants are effective in the procedure. Therefore, the purpose of our study was to assess the efficacy of atropine known as a muscular relaxant in ultrasound-guided reduction by saline enema in children with intussusception.Methods: All patients with intussusception diagnosed and treated in our department from July 2016 to February 2018 were included. Four hundred and thirty-seven children were enrolled and randomly divided into two groups: an atropine group and a control group. Intramuscular atropine at a dose of 0.02 mg per kilogram of body weight was administrated 15 min before ultrasound-guided reduction by saline enema in the atropine group. In the control group, the ultrasound-guided reduction was performed without using any muscular relaxants. The success rate, duration of the reduction, volume of saline, maximum intra-rectal pressure and complications were recorded and compared between the two groups.Results: The success rate was 95.9% (212 out of 221) and 94.9% (205 out of 216) in the atropine group and the control group, respectively. No significant difference was observed in the success rate between the two groups (P > 0.05). The duration of reduction was significantly lower in the atropine group than in the control group (P < 0.01). The volume of saline was also significantly lower in the atropine group than in the control group (P < 0.05). The maximum intra-rectal pressure showed no difference between the two groups (P > 0.05).Conclusion: Atropine premedication can facilitate ultrasound-guided reduction by saline enema in children with intussusception, by reducing the duration of reduction and the volume of saline in the procedure.
- Published
- 2019
- Full Text
- View/download PDF
4. Measurement consistency of dynamic stretching muscle stiffness evaluated using shear wave elastography: comparison among different stretched levels and ROI sizes.
- Author
-
Xiao Liu, Hong-Kui Yu, Shu-Ya Sheng, Si-Min Liang, Hao Lu, Li-Xian Gu, Pei Fu, Min Pan, Liu, Xiao, Yu, Hong-Kui, Sheng, Shu-Ya, Liang, Si-Min, Lu, Hao, Gu, Li-Xian, Fu, Pei, and Pan, Min
- Subjects
- *
SHEAR waves , *MODULUS of rigidity , *INTRACLASS correlation , *ELASTOGRAPHY , *MUSCLES , *ANKLE - Abstract
Aim: To investigate the reliability of quantitative analysis of dynamic stretching muscle stiffness using shear wave elas-tography (SWE), and to evaluate the influence of stretched levels and region of interest (ROI) sizes on the repeatability of SWE measurements.Materials and Methods: SWE videos of the gastrocnemius medius were collected during ankle movement from plantar flexion (PF) 40° to dorsiflexion (DF) 30°. Shear wave imageswere collected of ankle angles at PF 25°, 0°, DF 15°, and DF 30°, representing the slack status, mildly stretched level, moderately stretched level, and maximal stretched level of the gastrocnemius medius, respectively. ROI circles with diameters of 2 mm, 5 mm, and 8 mm were applied to measure the shear modulus. Intra-observer, and inter-observer repeatability of the measurements were compared among different stretched levels and ROI sizes.Results: Twenty-one healthy volunteers were enrolled. Muscle stiffness increased as the ankle DF increased. Intraclass correlation coefficients (ICCs) of intra-observer and inter-observer repeatability obtained for ROI sizes of 2 mm, 5 mm and 8 mm indicated good to excellent repeatability at all stretched levels.Conclusions: Shear wave elastography appeared to be a reliable tool to evaluate the dynamic stretching muscle stiffness with satisfactory repeatability at various stretched levels of gastrocnemius medius. Good to excellent repeatability was found using different ROI sizes. [ABSTRACT FROM AUTHOR]- Published
- 2021
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.