1. Clinical feasibility of deep learning based synthetic contrast enhanced abdominal CT in patients undergoing non enhanced CT scans
- Author
-
Seungchul Han, Jong-Min Kim, Junghoan Park, Se Woo Kim, Sungeun Park, Jungheum Cho, Sae-Jin Park, Han-Jae Chung, Seung-Min Ham, Sang Joon Park, and Jung Hoon Kim
- Subjects
Abdomen ,Diagnosis ,Tomography ,Deep learning ,Medicine ,Science - Abstract
Abstract Our objective was to develop and evaluate the clinical feasibility of deep-learning-based synthetic contrast-enhanced computed tomography (DL-SynCCT) in patients designated for nonenhanced CT (NECT). We proposed a weakly supervised learning with the utilization of virtual non-contrast CT (VNC) for the development of DL-SynCCT. Training and internal validations were performed with 2202 pairs of retrospectively collected contrast-enhanced CT (CECT) images with the corresponding VNC images acquired from dual-energy CT. Clinical validation was performed using an external validation set including 398 patients designated for true nonenhanced CT (NECT), from multiple vendors at three institutes. Detection of lesions was performed by three radiologists with only NECT in the first session and an additionally provided DL-SynCCT in the second session. The mean peak signal-to-noise ratio (PSNR) and structural similarity index map (SSIM) of the DL-SynCCT compared to CECT were 43.25 ± 0.41 and 0.92 ± 0.01, respectively. With DL-SynCCT, the pooled sensitivity for lesion detection (72.0% to 76.4%, P
- Published
- 2024
- Full Text