1. A sensitive acupuncture needle microsensor for real-time monitoring of nitric oxide in acupoints of rats
- Author
-
Lina Tang, Yutao Li, Hui Xie, Qing Shu, Fan Yang, Yan-ling Liu, Fengxia Liang, Hua Wang, Weihua Huang, and Guo-Jun Zhang
- Subjects
Medicine ,Science - Abstract
Abstract This study reports an acupuncture needle modified with an iron-porphyrin functionalized graphene composite (FGPC) for real-time monitoring of nitric oxide (NO) release in acupoints of rats. A gold film was first deposited to the needle surface to enhance the conductivity. The FGPC was prepared via hydrothermal synthesis, and subsequently applied to the tip surface of acupuncture needle by electrochemical deposition method. The functionalized needle enabled a specific and sensitive detection of NO based on the favorably catalytic properties of iron-porphyrin and the excellent conductivity of graphene. Amperometric data showed that the needle achieved not only a low detection limit down to 3.2 nM in PBS solution, but also a satisfactory selectivity. Interestingly, the functionalized needle could be inserted into the acupoints of rats for real-time monitoring of NO in vivo. It was found that a remarkable response to NO was respectively obtained in different acupoints when stimulated by L-arginine (L-Arg), revealing that the release of NO was detectable in acupoints. We expect this work would showcase the applications of acupuncture needle in detecting some important signaling molecules in vivo, and exploring the mechanism of acupuncture treatment.
- Published
- 2017
- Full Text
- View/download PDF