1. Intrarenal pressures during percutaneous nephrolithotomy: a porcine kidney model
- Author
-
Lee Chien Yap, Donnacha Hogan, Kenneth Patterson, Gerard McGuinness, Charles O’Connor, Ashraf Sharfi, and Derek Barry Hennessey
- Subjects
Kidney Calculi ,Swine ,Nephrology ,Urology ,Pressure ,Animals ,Urologic Surgical Procedures ,Nephrolithotomy, Percutaneous ,Intrarenal pressure ,Access sheath ,Kidney ,PCNL ,Nephrostomy, Percutaneous - Abstract
Background: Increased intrarenal pressure during endoscopic lithotripsy is associated with increased adverse outcomes. The objective of this study was to evaluate the effect of various devices on IRP during percutaneous intrarenal surgery in ex vivo porcine kidney models. Methods: Whole intact porcine urinary tracts were harvested. Intrarenal pressure was measured using cystometrometry software. Intrarenal pressure during PCNL was recorded using variations of percutaneous access sheath size, irrigation height of 100 cm and 60 cm, use of a ureteric catheter and use of suction. The primary outcome was absolute IRP measurements. Secondary outcomes were comparisons of IRP between techniques. Results: Using a 30 Fr vs 26 Fr access sheath and 26 Fr nephroscope the mean pressure at an irrigation height of 60 cm was significantly lower than 100 cm (p = 0.0013 vs p
- Published
- 2022
- Full Text