8 results on '"Do JL"'
Search Results
2. Homocysteine plasma levels as a marker of clinical severity in septic patients.
- Author
-
Coelho Neto A, Azevedo RP, Santos MB, Galdieri Lde C, D'Almeida V, Amaral JL, Freitas FG, and Machado FR
- Abstract
Objective: Homocysteine and sepsis are both associated with inflammation and endothelial activation. Therefore this study was aimed to evaluate if the plasma homocystein level is related with the septic patient clinical severity., Methods: Severe sepsis or septic shock patients, with less than 48 hours from organ dysfunction start, were admitted to this prospective observational study. Homocysteine levels were determined by the time of study admission and then on the Days 3, 7 and 14. The homocysteine association with the Sequential Organ Failure Assessment (SOFA) score was evaluated using the Sperman test, and its association with mortality using the Mann-Whitney test. A p<0.05 value was considered statistically significant., Results: Twenty one patients were enrolled, and 60 blood samples were collected to measure total homocysteine [median 6.92 (5.27 - 9.74 μmol/L)]. The Sperman correlation test showed no association between homocysteine and SOFA ( r=0.15 and p=0.26). Also no correlation was found for the homocysteine level by the study admission time and the difference between the Day 3 SOFA score versus by study admission (deltaSOFA) (r=0.04 and p=0.87). Homocysteine variation between the Day 3 and the study admission (deltaHmc) and SOFA score variation in the same period were not correlated (r=-0.11 and p=0.66). Homocysteine by the study admission was not correlated with death in intensive care unit rate (p= 0.46) or in-hospital death rate (p = 0.13). This was also true for deltaHmc (p=0.12 and p=0.99, respectively)., Conclusion: Baseline homocysteine levels and its variations within the first dysfunction days were not related with septic patients' worsened organ function parameters or mortality.
- Published
- 2010
3. Central and mixed venous oxygen saturation in septic shock: is there a clinically relevant difference?
- Author
-
Machado FR, Carvalho RB, Freitas FG, Sanches LC, Jackiu M, Mazza BF, Assunção M, Guimarães HP, and Amaral JL
- Abstract
Introduction: Central venous oxygen saturation (SvcO2) has been proposed as an alternative for mixed venous oxygen saturation (SvO2), with a variable level of acceptance according to available data. This study aimed to evaluate possible differences between SvO2 and SvcO2 or atrial venous saturation (SvaO2), with emphasis on the role of cardiac output and their impact on clinical management of the septic patient., Methods: This is an observational, prospective study of patients with septic shock monitored by pulmonary artery catheter. Blood was obtained simultaneously for SvcO2, SvO2 and SvaO2 determination. Linear correlation (significant if p<0.05) and agreement analysis (Bland-Altman) were performed with samples and subgroups according to cardiac output. Moreover, agreement about clinical management based on these samples was evaluated., Results: Sixty one measurements from 23 patients were obtained, median age of 65.0 (49.0-75.0) years and mean APACHE II of 27.7±6.3. Mean values of SvO2, SvcO2 and SvaO2 were 72.20±8.26%, 74.61±7.60% and 74.64±8.47%. Linear correlation test showed a weak correlation between SvO2 and SvcO2 (r=0.61, p<0.0001) and also between SvO2 and SvaO2 (r=0.70, p<0.0001). Agreements between SvcO2/SvO2 and SvaO2/SvO2 were -2.40±1.96 (-16.20 and 11.40) and -2.40±1.96 (-15.10 and 10.20), respectively, with no difference in the cardiac output subgroups. No agreement was found in clinical management for 27.8% of the cases, both for SvcO2/SvO2 and for SvaO2/SvO2., Conclusion: This study showed that the correlation and agreement between SvO2 and SvcO2 is weak and may lead to different clinical management.
- Published
- 2008
4. [Adverse systemic reactions in intensive care medicine after isolated limb perfusion with melphalan and hyperthermia: case report].
- Author
-
Arruda FO, Guimarães HP, Falcão LF, Leal PH, Lopes RD, Santos ID, and Amaral JL
- Abstract
Background and Objectives: The presence of adverse reactions, inherent to all treatments, justifies the necessity of deep knowledge, by the medical team of the prevention and treatment of occasional organic dysfunctions, reducing its impact. The purpose of this paper is to report a case comprising the several systemic adverse reactions after perfusion of limb with melphalan and hyperthermia., Case Report: A white female, 64-years old patient with diagnosis of melanoma in the medial malleoli region of the left lower limb. Six months after surgical removal of wound, an isolated perfusion of limb was carried out with melphalan and hyperthermia in order to curb the possible metastatic process in evolution. At admission in the ICU, the patient presented systemic inflammatory response syndrome (SIRS) with refractary hemodynamic instability to volemic expansion. During internation the patient evolved to acute lung edema and myocardial dysfunction, all reverted successfully., Conclusions: The potential presence of adverse reactions, inherent to all treatments, justify the necessity of knowledge by the intensive care team in the prevention and treatment of occasional organic dysfunctions, reducing the impact of morbidity and mortality.
- Published
- 2006
5. [Evaluation of T tube trial as a strategy of weaning from mechanical ventilation].
- Author
-
Assunção MS, Machado FR, Rosseti HB, Penna HG, Serrão CC, Silva WG, Souza AP, and Amaral JL
- Abstract
Background and Objectives: Weaning from mechanical ventilation (MV) is an important strategy to reduce morbidity and mortality in critical care patients. In this setting, this study aimed at evaluation of T-tube trial (TT) in weaning from MV., Methods: Patient admitted in the ICU were included if they present the following inclusion criteria: MV > 24 hours, no neuromuscular disorders, PaO2/FiO2 ratio >200, hemodynamic stability, reversion of the cause of respiratory failure, adequate respiratory drive. All were submitted to TT. Failure was defined by the presence of one of these symptoms: RR > 30 ipm, hypoxemia, tachycardia, arrhythmia, hypertension or hypotension. After two hours of TT, patients without failure criteria were extubated. After 48 hours of adequate spontaneous respiration the patient was considered successful weaned. Results were considered significant if p < 0.05., Results: Forty-nine patients were included with a mean age 51.8 ± 21.7 years. The incidence of ARDS and septic shock were 26.5% and 32.7% and mean duration of MV was 11.9 ± 13 days. Discontinuation of MV occurred in 79.2%, reintubation in 31.6%, in a mean time of 13 ± 8.7 hours and in 75% of the cases it was due to respiratory failure. There was no correlation between success in TT and hemoglobin levels, PaO2/FiO2 ratio, age, gender, prior ARDS or septic shock. Weaning success was not correlated with none of the above variables., Conclusions: TT was adequated for weaning from mechanical ventilation in the majority of the cases. However, reintubation rate was high. Possible causes are the long period of TT, prior mechanical ventilation or the failure in the criteria used to indicate extubation.
- Published
- 2006
6. [Brazilian consensus of monitoring and hemodynamic support - part III: alternative methods for cardiac output monitoring and volemia estimation].
- Author
-
Schettino G, Ederlon R, Mendes CL, Réa-Neto A, David CM, Lobo SM, Barros A, Silva E, Friedman G, Amaral JL, Park M, Monachini M, Oliveira MC, Assunção MS, Akamine N, Mello PV, Pereira RA, Costa Filho R, Araújo S, Pinto SF, Ferreira S, Mitushima SM, Agareno S, and Brilhante YN
- Abstract
Background and Objectives: Cardiac output and preload as absolute data do not offer helpful information about the hemodynamic of critically ill patients. However, monitoring the response of these variables to volume challenge or inotropic drugs is a very useful tool in the critical care setting, particularly for patients with signs of tissue hypoperfusion. Although PAC remains the " gold standard" to measure cardiac output and preload, new and alternative technologies were developed to evaluate these hemodynamic variables., Methods: Modified Delphi methodology was used to create and quantify the consensus between the participants. AMIB indicated a coordinator who invited more six experts in the area of monitoring and hemodynamic support to constitute the Consensus Advisory Board. Twenty three physician and two nurses selected from different regions of the country completed the expert panel, which reviewed the pertinent bibliography listed at the MEDLINE in the period from 1996 to 2004., Results: Recommendations regarding the use of arterial pulse pressure variation during mechanical ventilation, continuous arterial pulse contour and lithium dilution cardiac output measurements, esophageal Doppler waveform, thoracic electrical bioimpedance, echocardiography and partial CO2 rebreathing for monitoring cardiac output and preload were created., Conclusions: The new and less invasive techniques for the measurement of cardiac output, preload or fluid responsiveness are accurate and may be an alternative to PAC in critically ill patients.
- Published
- 2006
7. [Quality and humanization of the attendance in Intensive Care Medicine. What the parents think's?].
- Author
-
Wallau RA, Guimarães HP, Falcão LF, Lopes RD, Leal PH, Senna AP, Alheira RG, Machado FR, and Amaral JL
- Abstract
Background and Objectives: This study aims to describe the view of family members about the quality of care given in a general intensive care unit of a university hospital., Methods: A questionnaire to evaluate the level of satisfaction with the care was elaborated. The study included family members of patients with a length of stay more than 48h who already had visited the patient one time or more during the period. The exclusion criterion was family of admitted patients with less than 48h of ICU stay, family members who had not visited the patient at all or family members who did not desire to answer the questionnaire for any personal reason., Results: There were 100 relatives interviewed face to face. The most frequent complaint that had generated the greatest concern was the general status of the patient, present in 28% of the interviews. A total of 96% considered the quality of the medical team as excellent or good. However, 15% declared to be unsatisfied with the medical information given and the other 5%, although admitting satisfaction, complained about having to talk with different doctors each day., Conclusions: Imperfections in the communication appears as the main predictor of unsatisfactory quality of the service in the view of the family members. Although one cannot directly compare the degree of satisfaction between distinct studies due to different methodologies, we considered that in the presented sample the recognition of the most frequent factors of dissatisfaction can point out areas for improvement in the quality of care offered in the ICU.
- Published
- 2006
8. [Part II: basic hemodynamic monitoring and the use of pulmonary artery catheter].
- Author
-
Dias FS, Rezende E, Mendes CL, Réa-Neto A, David CM, Schettino G, Lobo SM, Barros A, Silva E, Friedman G, Amaral JL, Park M, Monachini M, Oliveira MC, Assunção MS, Akamine N, Mello PV, Pereira RA, Costa Filho R, Araújo S, Félix Pinto S, Ferreira S, Mitushima SM, Agareno S, and Brilhante YN
- Abstract
Background and Objectives: Monitoring of vital functions is one of the most important tools in the management of critically ill patients. Nowadays is possible to detect and analyze a great deal of physiologic data using a lot of invasive and non-invasive methods. The intensivist must be able to select and carry out the most appropriate monitoring technique according to the patient requirements and taking into account the benefit/risk ratio. Despite the fast development of non invasive monitoring techniques, invasive hemodynamic monitoring using Pulmonary Artery Catheter still is one of the basic procedures in Critical Care. The aim was to define recommendations about clinical utility of basic hemodynamic monitoring methods and the Use of Pulmonary Artery Catheter., Methods: Modified Delphi methodology was used to create and quantify the consensus between the participants. AMIB indicated a coordinator who invited more six experts in the area of monitoring and hemodynamic support to constitute the Consensus Advisory Board. Twenty-five physicians and nurses selected from different regions of the country completed the expert panel, which reviewed the pertinent bibliography listed at the MEDLINE in the period from 1996 to 2004., Results: Recommendations were made based on 55 questions about the use of central venous pressure, invasive arterial pressure, pulmonary artery catheter and its indications in different settings., Conclusions: Evaluation of central venous pressure and invasive arterial pressure, besides variables obtained by the PAC allow the understanding of cardiovascular physiology that is of great value to the care of critically ill patients. However, the correct use of these tools is fundamental to achieve the benefits due to its use.
- Published
- 2006
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.