11 results on '"Kurz, Christopher"'
Search Results
2. 927: Patient-specific deep learning for real-time tumor tracking in MR-guided radiotherapy.
- Author
-
Velezmoro, Laura, Lombardo, Elia, Marschner, Sebastian, Reiner, Michael, Corradini, Stefanie, Belka, Claus, Riboldi, Marco, Kurz, Christopher, and Landry, Guillaume
- Subjects
- *
DEEP learning , *RADIOTHERAPY , *TUMORS - Published
- 2024
- Full Text
- View/download PDF
3. 534: Predicting radiation-induced pneumonitis using MR-based ventilation imaging at a 0.35 T MR-Linac.
- Author
-
Klaar, Rabea, Rabe, Moritz, Stüber, Anna Theresa, Corradini, Stefanie, Eze, Chukwuka, Belka, Claus, Landry, Guillaume, Kurz, Christopher, and Dinkel, Julien
- Subjects
- *
RADIATION pneumonitis , *VENTILATION , *FORECASTING - Published
- 2024
- Full Text
- View/download PDF
4. 2486: Impact of patient specific deep learning OAR segmentation on accumulated online adapted MRgRT dose.
- Author
-
Xiong, Yuqing, Kawula, Maria, Ribeiro, Marvin, Marschner, Sebastian, Corradini, Stefanie, Belka, Claus, Landry, Guillaume, Rabe, Moritz, and Kurz, Christopher
- Subjects
- *
DEEP learning - Published
- 2024
- Full Text
- View/download PDF
5. 1690: Comparing Transformer training strategies for real-time tumor tracking in MRI-guided radiotherapy.
- Author
-
Lombardo, Elia, Velezmoro, Laura, Marschner, Sebastian, Reiner, Michael, Corradini, Stefanie, Belka, Claus, Riboldi, Marco, Kurz, Christopher, and Landry, Guillaume
- Subjects
- *
RADIOTHERAPY , *TUMORS - Published
- 2024
- Full Text
- View/download PDF
6. Multi-criterial patient positioning based on dose recalculation on scatter-corrected CBCT images.
- Author
-
Hofmaier, Jan, Haehnle, Jonas, Kurz, Christopher, Landry, Guillaume, Maihoefer, Cornelius, Schüttrumpf, Lars, Süss, Philipp, Teichert, Katrin, Söhn, Matthias, Spahr, Nadine, Brachmann, Christoph, Weiler, Florian, Thieke, Christian, Küfer, Karl-Heinz, Belka, Claus, Parodi, Katia, and Kamp, Florian
- Subjects
- *
CONE beam computed tomography , *RADIATION doses , *PATIENT positioning , *RETROSPECTIVE studies , *TUMOR treatment ,PAROTID gland tumors - Abstract
Background and purpose Our aim was to evaluate the feasibility and potential advantages of dose guided patient positioning based on dose recalculation on scatter corrected cone beam computed tomography (CBCT) image data. Material and methods A scatter correction approach has been employed to enable dose calculations on CBCT images. A recently proposed tool for interactive multicriterial dose-guided patient positioning which uses interpolation between pre-calculated sample doses has been utilized. The workflow was retrospectively evaluated for two head and neck patients with a total of 39 CBCTs. Dose–volume histogram (DVH) parameters were compared to rigid image registration based isocenter corrections (clinical scenario). Results The accuracy of the dose interpolation was found sufficient, facilitating the implementation of dose guided patient positioning. Compared to the clinical scenario, the mean dose to the parotid glands could be improved for 2 out of 5 fractions for the first patient while other parameters were preserved. For the second patient, the mean coverage over all fractions of the high dose PTV could be improved by 4%. For this patient, coverage improvements had to be traded against organ at risk (OAR) doses within their clinical tolerance limits. Conclusions Dose guided patient positioning using in-room CBCT data is feasible and offers increased control over target coverage and doses to OARs. [ABSTRACT FROM AUTHOR]
- Published
- 2017
- Full Text
- View/download PDF
7. MRI-based ventilation and perfusion imaging to predict radiation-induced pneumonitis in lung tumor patients at a 0.35 T MR-Linac.
- Author
-
Klaar, Rabea, Rabe, Moritz, Stüber, Anna Theresa, Hering, Svenja, Corradini, Stefanie, Eze, Chukwuka, Marschner, Sebastian, Belka, Claus, Landry, Guillaume, Dinkel, Julien, and Kurz, Christopher
- Subjects
- *
STEREOTACTIC radiotherapy , *RADIATION pneumonitis , *RECEIVER operating characteristic curves , *MAGNETIC resonance imaging , *PERFUSION imaging - Abstract
Radiation-induced pneumonitis (RP), diagnosed 6–12 weeks after treatment, is a complication of lung tumor radiotherapy. So far, clinical and dosimetric parameters have not been reliable in predicting RP. We propose using non-contrast enhanced magnetic resonance imaging (MRI) based functional parameters acquired over the treatment course for patient stratification for improved follow-up. 23 lung tumor patients received MR-guided hypofractionated stereotactic body radiation therapy at a 0.35 T MR-Linac. Ventilation- and perfusion-maps were generated from 2D-cine MRI-scans acquired after the first and last treatment fraction (Fx) using non-uniform Fourier decomposition. The relative differences in ventilation and perfusion between last and first Fx in three regions (planning target volume (PTV), lung volume receiving more than 20 Gy (V20) excluding PTV, whole tumor-bearing lung excluding PTV) and three dosimetric parameters (mean lung dose, V20, mean dose to the gross tumor volume) were investigated. Univariate receiver operating characteristic curve - area under the curve (ROC–AUC) analysis was performed (endpoint RP grade ≥ 1) using 5000 bootstrapping samples. Differences between RP and non-RP patients were tested for statistical significance with the non-parametric Mann–Whitney U test (α = 0.05). 14/23 patients developed RP of grade ≥ 1 within 3 months. The dosimetric parameters showed no significant differences between RP and non-RP patients. In contrast, the functional parameters, especially the relative ventilation difference in the PTV, achieved a p -value < 0.05 and an AUC value of 0.84. MRI-based functional parameters extracted from 2D-cine MRI-scans were found to be predictive of RP development in lung tumor patients. [Display omitted] • Non-contrast enhanced functional imaging during lung SBRT at low-field MR-Linac. • Non-uniform Fourier decomposition to extract ventilation and perfusion over treatment. • Ventilation changes in high-dose region predictive of radiation-induced pneumonitis. • Higher predictive performance of functional than dosimetric parameters. [ABSTRACT FROM AUTHOR]
- Published
- 2024
- Full Text
- View/download PDF
8. Real-time motion management in MRI-guided radiotherapy: Current status and AI-enabled prospects.
- Author
-
Lombardo, Elia, Dhont, Jennifer, Page, Denis, Garibaldi, Cristina, Künzel, Luise A., Hurkmans, Coen, Tijssen, Rob H.N., Paganelli, Chiara, Liu, Paul Z.Y., Keall, Paul J., Riboldi, Marco, Kurz, Christopher, Landry, Guillaume, Cusumano, Davide, Fusella, Marco, and Placidi, Lorenzo
- Subjects
- *
WORKFLOW management , *RADIOTHERAPY , *ARTIFICIAL intelligence , *WORKFLOW - Abstract
• Description of intra-fractional motion management workflow in MRI-guided radiotherapy. • Envisioned workflow with both highest dosimetric accuracy and duty cycle efficiency. • Focus on real-time implementation based on artificial intelligence. MRI-guided radiotherapy (MRIgRT) is a highly complex treatment modality, allowing adaptation to anatomical changes occurring from one treatment day to the other (inter-fractional), but also to motion occurring during a treatment fraction (intra-fractional). In this vision paper, we describe the different steps of intra-fractional motion management during MRIgRT, from imaging to beam adaptation, and the solutions currently available both clinically and at a research level. Furthermore, considering the latest developments in the literature, a workflow is foreseen in which motion-induced over- and/or under-dosage is compensated in 3D, with minimal impact to the radiotherapy treatment time. Considering the time constraints of real-time adaptation, a particular focus is put on artificial intelligence (AI) solutions as a fast and accurate alternative to conventional algorithms. [ABSTRACT FROM AUTHOR]
- Published
- 2024
- Full Text
- View/download PDF
9. Evaluation of real-time tumor contour prediction using LSTM networks for MR-guided radiotherapy.
- Author
-
Lombardo, Elia, Rabe, Moritz, Xiong, Yuqing, Nierer, Lukas, Cusumano, Davide, Placidi, Lorenzo, Boldrini, Luca, Corradini, Stefanie, Niyazi, Maximilian, Reiner, Michael, Belka, Claus, Kurz, Christopher, Riboldi, Marco, and Landry, Guillaume
- Subjects
- *
MAGNETIC resonance imaging , *ARTIFICIAL intelligence - Abstract
• Comparison of three AI algorithms for real-time prediction of future tumor contours. • Usage of clinical cine MRI data from low-field MR-linacs from two institutions. • Prediction times compatible with reported MLC-tracking latencies on MR-linacs. Magnetic resonance imaging guided radiotherapy (MRgRT) with deformable multileaf collimator (MLC) tracking would allow to tackle both rigid displacement and tumor deformation without prolonging treatment. However, the system latency must be accounted for by predicting future tumor contours in real-time. We compared the performance of three artificial intelligence (AI) algorithms based on long short-term memory (LSTM) modules for the prediction of 2D-contours 500 ms into the future. Models were trained (52 patients, 3.1 h of motion), validated (18 patients, 0.6 h) and tested (18 patients, 1.1 h) with cine MRs from patients treated at one institution. Additionally, we used three patients (2.9 h) treated at another institution as second testing set. We implemented 1) a classical LSTM network (LSTM-shift) predicting tumor centroid positions in superior-inferior and anterior-posterior direction which are used to shift the last observed tumor contour. The LSTM-shift model was optimized both in an offline and online fashion. We also implemented 2) a convolutional LSTM model (ConvLSTM) to directly predict future tumor contours and 3) a convolutional LSTM combined with spatial transformer layers (ConvLSTM-STL) to predict displacement fields used to warp the last tumor contour. The online LSTM-shift model was found to perform slightly better than the offline LSTM-shift and significantly better than the ConvLSTM and ConvLSTM-STL. It achieved a 50% Hausdorff distance of 1.2 mm and 1.0 mm for the two testing sets, respectively. Larger motion ranges were found to lead to more substantial performance differences across the models. LSTM networks predicting future centroids and shifting the last tumor contour are the most suitable for tumor contour prediction. The obtained accuracy would allow to reduce residual tracking errors during MRgRT with deformable MLC-tracking. [ABSTRACT FROM AUTHOR]
- Published
- 2023
- Full Text
- View/download PDF
10. First clinical investigation of a 4D maximum likelihood reconstruction for 4D PET-based treatment verification in ion beam therapy.
- Author
-
Gianoli, Chiara, De Bernardi, Elisabetta, Ricotti, Rosalinda, Kurz, Christopher, Bauer, Julia, Riboldi, Marco, Baroni, Guido, Debus, Jürgen, and Parodi, Katia
- Subjects
- *
POSITRON emission tomography , *ION beams , *CARBON , *IMAGE quality analysis , *MAXIMUM likelihood statistics , *THERAPEUTICS - Abstract
Background and purpose In clinical applications of Positron Emission Tomography (PET)-based treatment verification in ion beam therapy (PT-PET), detection and interpretation of inconsistencies between Measured PET and Expected PET are mostly limited by Measured PET noise, due to low count statistics, and by Expected PET bias, especially due to inaccurate washout modelling in off-line implementations. In this work, a recently proposed 4D Maximum Likelihood (ML) reconstruction algorithm which considers Measured PET and Expected PET as two different motion phases of a 4D dataset is assessed on clinical 4D PET-CT datasets acquired after carbon ion therapy. Material and methods The 4D ML reconstruction algorithm estimates: (1) Measured PET of enhanced image quality with respect to the conventional Measured PET, thanks to the exploitation of Expected PET; (2) the deformation field mapping the Expected PET onto the Measured PET as a measure of the occurred displacements. Results Results demonstrate the desired sensitivity to inconsistencies due to breathing motion and/or setup modification, robustness to noise in different count statistics scenarios, but a limited sensitivity to Expected PET washout inaccuracy. Conclusions The 4D ML reconstruction algorithm supports clinical 4D PT-PET in ion beam therapy. The limited sensitivity to washout inaccuracy can be detected and potentially overcome. [ABSTRACT FROM AUTHOR]
- Published
- 2017
- Full Text
- View/download PDF
11. Implementation and initial clinical experience of offline PET/CT-based verification of scanned carbon ion treatment.
- Author
-
Bauer, Julia, Unholtz, Daniel, Sommerer, Florian, Kurz, Christopher, Haberer, Thomas, Herfarth, Klaus, Welzel, Thomas, Combs, Stephanie E., Debus, Jürgen, and Parodi, Katia
- Subjects
- *
POSITRON emission tomography , *COMPUTED tomography , *RADIOTHERAPY treatment planning , *ION beams , *PHYSIOLOGICAL effects of carbon , *RADIOISOTOPE therapy - Abstract
Abstract: Background and purpose: We report on the implementation of offline PET/CT-based treatment verification at the Heidelberg Ion Beam Therapy Centre (HIT) and present first clinical cases for post-activation measurements after scanned carbon ion irradiation. Key ingredient of this in-vivo treatment verification is the comparison of irradiation-induced patient activation measured by a PET scanner with a prediction simulated by means of Monte Carlo techniques. Material and methods: At HIT, a commercial full-ring PET/CT scanner has been installed in close vicinity to the treatment rooms. After selected irradiation fractions, the patient either walks to the scanner for acquisition of the activation data or is transported using a shuttle system. The expected activity distribution is obtained from the production of β+-active isotopes simulated by the FLUKA code on the basis of the patient-specific treatment plan, post-processed considering the time course of the respective treatment fraction, the estimated biological washout of the induced activity and a simplified model of the imaging process. Results: We present four patients with different indications of head, head/neck, liver and pelvic tumours. A clear correlation between the measured PET signal and the simulated activity pattern is observed for all patients, thus supporting a proper treatment delivery. In the case of a pelvic tumour patient it was possible to detect minor treatment delivery inaccuracies. Conclusions: The initial clinical experience proves the feasibility of the implemented strategy for offline confirmation of scanned carbon ion irradiation and therefore constitutes a first step towards a comprehensive PET/CT-based treatment verification in the clinical routine at HIT. [Copyright &y& Elsevier]
- Published
- 2013
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.