1. Stepping-Table Gadolinium- enhanced Digital Subtraction MR Angiography of the Aorta and Lower Extremity Arteries: Preliminary Experience
- Author
-
James F. M. Meaney, David Kessel, Sam Chakraverty, Michael A. Smith, Iain K Robertson, Marc Kouwenhoven, Andrea Kassner, John P. Ridgway, and Aleksandra Radjenovic
- Subjects
Gadolinium DTPA ,Male ,medicine.medical_specialty ,Aortic Diseases ,Contrast Media ,Arterial Occlusive Diseases ,Sensitivity and Specificity ,Magnetic resonance angiography ,Predictive Value of Tests ,medicine.artery ,Occlusion ,Image Processing, Computer-Assisted ,Humans ,Medicine ,Radiology, Nuclear Medicine and imaging ,Aorta, Abdominal ,Aged ,Observer Variation ,Leg ,Aorta ,medicine.diagnostic_test ,business.industry ,Abdominal aorta ,Angiography, Digital Subtraction ,Magnetic resonance imaging ,medicine.disease ,Stenosis ,medicine.anatomical_structure ,Subtraction Technique ,Angiography ,cardiovascular system ,Female ,Radiology ,business ,Magnetic Resonance Angiography ,Artery - Abstract
To compare stepping-table digital subtraction gadolinium-enhanced magnetic resonance (MR) angiography of the distal aorta and lower extremity arteries with conventional catheter digital subtraction x-ray angiography in patients with arterio-occlusive disease.Twenty patients underwent both conventional catheter angiography and fast three-dimensional gadolinium-enhanced MR angiography of the aorta and outflow vessels at 1.5 T; the images were acquired in three consecutive imaging locations during a single infusion of a gadolinium chelate.Compared with catheter angiography, according to the findings of two blinded independent reviewers, MR angiography had sensitivities of 81% and 89% and specificities of 91% and 95%, respectively, for demonstration of insignificant (or = 50%) stenosis versus significant (51%-100%) stenosis. For demonstration of occlusion, the sensitivity and specificity were 94% and 97%, respectively, by consensus. There was good interobserver correlation between the two readers overall (kappa = 0.65 for reporting the degree of narrowing in all lesions; 0.86, for reporting of insignificant versus significant stenoses; and 0.928, for reporting of occluded versus patient segments).Stepping-table digital subtraction contrast material-enhanced MR angiography has high accuracy compared with catheter angiography in patients with arterio-occlusive disease of the aorta and outflow vessels. These preliminary study results suggest that this technique may ultimately provide a safe, noninvasive, and cost-effective alternative to catheter angiography.
- Published
- 1999