1. Interferon-beta bioactivity measurement in multiple sclerosis: feasibility for routine clinical practice.
- Author
-
van der Voort LF, Kok A, Visser A, Oudejans CB, Caldano M, Gilli F, Bertolotto A, Polman CH, and Killestein J
- Subjects
- Adult, Antibodies immunology, Antibodies pharmacology, Feasibility Studies, Female, GTP-Binding Proteins genetics, GTP-Binding Proteins immunology, Gene Expression Regulation, Viral drug effects, Gene Expression Regulation, Viral immunology, Humans, Immunoassay methods, Male, Middle Aged, Multiple Sclerosis, Relapsing-Remitting immunology, Myxovirus Resistance Proteins, Neutralization Tests, RNA, Messenger metabolism, Young Adult, Drug Monitoring methods, Immunologic Factors administration & dosage, Immunologic Factors immunology, Interferon-beta administration & dosage, Interferon-beta immunology, Multiple Sclerosis, Relapsing-Remitting drug therapy
- Abstract
Background: Neutralising antibodies (NAb) to interferon beta (IFN beta) are associated with a reduced bioactivity and efficacy of IFN beta in multiple sclerosis (MS). Unclear is how to apply IFN beta bioactivity measurements (quantification of Myxovirus resistance protein A (MxA) mRNA) in clinical practice., Objectives: To evaluate value and feasibility of IFN beta bioactivity measurement with a single MxA mRNA measurement for screening and a second measurement before and after IFN beta administration for definite confirmation of IFN beta bioactivity status., Methods: In 79 MS patients MxA mRNA expression was determined 4 hours after IFN beta administration. If inadequate, MxA mRNA expression testing was repeated 3 months afterwards, comparing post- and pre injection samples to determine whether IFNb bioactivity was persistently lacking. MxA mRNA expression was compared to NA beta titres, determined by the cytopathic effect assay (CPE)., Results: NAb titres correlated significantly with MxA mRNA expression and MxA mRNA induction. Of all screened patients, only one patient had adequate MxA mRNA expression and high NAb titres simultaneously. Of the biological non-responders at second measurement (21/55), 17 (81%) were high-titre NAb positive, 1 (5%) was low-titre NAb positive and 3 (14%) were NAb negative. Without considering the pre-injection measurement, two more NAb negative patients would have tested negative for IFN beta bioactivity, emphasizing the need of a pre-injection sample., Conclusions: Our data suggest that for IFN beta bioactivity screening a single post-injection measurement seems reasonable. However, MxA induction measurement based on both pre- and post-IFN beta injection samples at second measurement is somewhat more precise in determining ultimate IFN beta bioactivity status.
- Published
- 2009
- Full Text
- View/download PDF