1. Comparison of cyclic fatigue resistance between different NiTi instruments with 4% taper
- Author
-
Ahmet Demirhan Uygun, Fatih Seckin, Mehmet Tanriver, İbrahim Ersoy, and Elif Kol
- Subjects
Cyclic stress ,Histology ,business.industry ,0206 medical engineering ,030206 dentistry ,02 engineering and technology ,020601 biomedical engineering ,03 medical and health sciences ,Medical Laboratory Technology ,0302 clinical medicine ,Nickel titanium ,Medicine ,Anatomy ,Composite material ,business ,Instrumentation - Abstract
The aim of this study was to make a comparison between the cyclic fatigue (CF) resistance of F360, twisted files (TF), FlexMaster (FM) and RaCE instruments with 4% taper. A total of 40 instruments were evaluated 8 mm from the tip. A stainless steel block with a simulated canal of 1.5 mm diameter, and a 60° angle of curvature was tested using CF testing. One-way ANOVA and posthoc Tukey's test (P 0.05). F360 instruments with a double S cross-section had the highest CF resistance among the group. The TF led the NiTi rotary files to be more resistant to fatigue than the FM and RaCE instruments.