13 results on '"Niatsetski, Y"'
Search Results
2. Design and characterization of a new high‐dose‐rate brachytherapy Valencia applicator for larger skin lesions
- Author
-
Candela‐Juan, C., primary, Niatsetski, Y., additional, van der Laarse, R., additional, Granero, D., additional, Ballester, F., additional, Perez‐Calatayud, J., additional, and Vijande, J., additional
- Published
- 2016
- Full Text
- View/download PDF
3. Comparison and uncertainty evaluation of different calibration protocols and ionization chambers for low-energy surface brachytherapy dosimetry
- Author
-
Candela-Juan, C., primary, Vijande, J., additional, García-Martínez, T., additional, Niatsetski, Y., additional, Nauta, G., additional, Schuurman, J., additional, Ouhib, Z., additional, Ballester, F., additional, and Perez-Calatayud, J., additional
- Published
- 2015
- Full Text
- View/download PDF
4. SU‐E‐T‐720: Surface Electronic Brachytherapy Dosimetry: Comparison and Uncertainty Evaluation of Different Calibration Protocols and Ionization Chambers
- Author
-
Candela‐Juan, C, primary, Garcia‐Martinez, T, additional, Niatsetski, Y, additional, Schuurman, J, additional, Nauta, G, additional, Vijande, J, additional, Ouhib, Z, additional, Ballester, F, additional, and Perez‐Calatayud, J, additional
- Published
- 2015
- Full Text
- View/download PDF
5. Comment on "Comparison and uncertainty evaluation of different calibration protocols and ionization chambers for low-energy surface brachytherapy dosimetry".
- Author
-
Fulkerson, Regina, Candela-Juana, C., Vijande, J., García-Martínez, T., Niatsetski, Y., Nauta, G., Schuurman, J., Ouhib, Z., Ballester, F., and Perez-Calatayud, J.
- Subjects
IONIZATION chambers ,RADIOISOTOPE brachytherapy ,RADIATION dosimetry ,CALIBRATION ,MEDICAL physics - Published
- 2016
- Full Text
- View/download PDF
6. A Monte Carlo study of the relative biological effectiveness in surface brachytherapy.
- Author
-
Valdes-Cortez C, Niatsetski Y, Perez-Calatayud J, Ballester F, and Vijande J
- Subjects
- DNA Damage radiation effects, Electronics, Humans, Monte Carlo Method, Radioisotopes, Brachytherapy adverse effects, Brachytherapy methods, Relative Biological Effectiveness
- Abstract
Purpose: This work aims to simulate clustered DNA damage from ionizing radiation and estimate the relative biological effectiveness (RBE) for radionuclide (rBT)- and electronic (eBT)-based surface brachytherapy through a hybrid Monte Carlo (MC) approach, using realistic models of the sources and applicators., Methods: Damage from ionizing radiation has been studied using the Monte Carlo Damage Simulation algorithm using as input the primary electron fluence simulated using a state-of-the-art MC code, PENELOPE-2018. Two
192 Ir rBT applicators, Valencia and Leipzig, one60 Co source with a Freiburg Flap applicator (reference source), and two eBT systems, Esteya and INTRABEAM, have been included in this study implementing full realizations of their geometries as disclosed by the manufacturer. The role played by filtration and tube kilovoltage has also been addressed., Results: For rBT, an RBE value of about 1.01 has been found for the applicators and phantoms considered. In the case of eBT, RBE values for the Esteya system show an almost constant RBE value of about 1.06 for all depths and materials. For INTRABEAM, variations in the range of 1.12-1.06 are reported depending on phantom composition and depth. Modifications in the Esteya system, filtration, and tube kilovoltage give rise to variations in the same range., Conclusions: Current clinical practice does not incorporate biological effects in surface brachytherapy. Therefore, the same absorbed dose is administered to the patients independently on the particularities of the rBT or eBT system considered. The almost constant RBE values reported for rBT support that assumption regardless of the details of the patient geometry, the presence of a flattening filter in the applicator design, or even significant modifications in the photon energy spectra above 300 keV. That is not the case for eBT, where a clear dependence on the eBT system and the characteristics of the patient geometry are reported. A complete study specific for each eBT system, including detailed applicator characteristics (size, shape, filtering, among others) and common anatomical locations, should be performed before adopting an existing RBE value., (© 2022 American Association of Physicists in Medicine.)- Published
- 2022
- Full Text
- View/download PDF
7. Bi-objective optimization of catheter positions for high-dose-rate prostate brachytherapy.
- Author
-
van der Meer MC, Bosman PAN, Niatsetski Y, Alderliesten T, van Wieringen N, Pieters BR, and Bel A
- Subjects
- Catheters, Humans, Male, Radiotherapy Dosage, Radiotherapy Planning, Computer-Assisted, Retrospective Studies, Brachytherapy, Prostatic Neoplasms radiotherapy
- Abstract
Purpose: Bi-objective simultaneous optimization of catheter positions and dwell times for high-dose-rate (HDR) prostate brachytherapy, based directly on dose-volume indices, has shown promising results. However, optimization with the state-of-the-art evolutionary algorithm MO-RV-GOMEA so far required several hours of runtime, and resulting catheter positions were not always clinically feasible. The aim of this study is to extend the optimization model and apply GPU parallelization to achieve clinically acceptable computation times. The resulting optimization procedure is compared with a previously introduced method based solely on geometric criteria, the adapted Centroidal Voronoi Tessellations (CVT) algorithm., Methods: Bi-objective simultaneous optimization was performed with a GPU-parallelized version of MO-RV-GOMEA. This optimization of catheter positions and dwell times was retrospectively applied to the data of 26 patients previously treated with HDR prostate brachytherapy for 8-16 catheters (steps of 2). Optimization of catheter positions using CVT was performed in seconds, after which optimization of only the dwell times using MO-RV-GOMEA was performed in 1 min., Results: Simultaneous optimization of catheter positions and dwell times using MO-RV-GOMEA was performed in 5 min. For 16 down to 8 catheters (steps of 2), MO-RV-GOMEA found plans satisfying the planning-aims for 20, 20, 18, 14, and 11 out of the 26 patients, respectively. CVT achieved this for 19, 17, 13, 9, and 2 patients, respectively. The P-value for the difference between MO-RV-GOMEA and CVT was 0.023 for 16 catheters, 0.005 for 14 catheters, and <0.001 for 12, 10, and 8 catheters., Conclusions: With bi-objective simultaneous optimization on a GPU, high-quality catheter positions can now be obtained within 5 min, which is clinically acceptable, but slower than CVT. For 16 catheters, the difference between MO-RV-GOMEA and CVT is clinically irrelevant. For 14 catheters and less, MO-RV-GOMEA outperforms CVT in finding plans satisfying all planning-aims., (© 2020 The Authors. Medical Physics published by Wiley Periodicals LLC on behalf of American Association of Physicists in Medicine.)
- Published
- 2020
- Full Text
- View/download PDF
8. Surface brachytherapy: Joint report of the AAPM and the GEC-ESTRO Task Group No. 253.
- Author
-
Fulkerson RK, Perez-Calatayud J, Ballester F, Buzurovic I, Kim Y, Niatsetski Y, Ouhib Z, Pai S, Rivard MJ, Rong Y, Siebert FA, Thomadsen BR, and Weigand F
- Subjects
- Calibration, Radiotherapy Dosage, Research Report, Brachytherapy
- Abstract
The surface brachytherapy Task Group report number 253 discusses the common treatment modalities and applicators typically used to treat lesions on the body surface. Details of commissioning and calibration of the applicators and systems are discussed and examples are given for a risk-based analysis approach to the quality assurance measures that are necessary to consider when establishing a surface brachytherapy program., (© 2020 American Association of Physicists in Medicine.)
- Published
- 2020
- Full Text
- View/download PDF
9. On the use of the absorbed depth-dose measurements in the beam calibration of a surface electronic high-dose-rate brachytherapy unit, a Monte Carlo-based study.
- Author
-
Valdes-Cortez C, Niatsetski Y, Ballester F, Vijande J, Candela-Juan C, and Perez-Calatayud J
- Subjects
- Air, Calibration, Equipment Design, Monte Carlo Method, Permeability, Reproducibility of Results, Uncertainty, Water, X-Rays, Brachytherapy instrumentation, Radiometry instrumentation, Radiotherapy Dosage, Radiotherapy Planning, Computer-Assisted instrumentation
- Abstract
Purpose: To evaluate the use of the absorbed depth-dose as a surrogate of the half-value layer in the calibration of a high-dose-rate electronic brachytherapy (eBT) equipment. The effect of the manufacturing tolerances and the absorbed depth-dose measurement uncertainties in the calibration process are also addressed., Methods: The eBT system Esteya
® (Elekta Brachytherapy, Veenendaal, The Netherlands) has been chosen as a proof-of-concept to illustrate the feasibility of the proposed method, using its 10 mm diameter applicator. Two calibration protocols recommended by the AAPM (TG-61) and the IAEA (TRS-398) for low-energy photon beams were evaluated. The required Monte Carlo (MC) simulations were carried out using PENELOPE2014. Several MC simulations were performed modifying the flattening filter thickness and the x-ray tube potential, generating one absorbed depth-dose curve and a complete set of parameters required in the beam calibration (i.e., HVL, backscatter factor (Bw ), and mass energy-absorption coefficient ratios (µen /ρ)water,air ), for each configuration. Fits between each parameter and some absorbed dose-ratios calculated from the absorbed depth-dose curves were established. The effect of the manufacturing tolerances and the absorbed dose-ratio uncertainties over the calibration process were evaluated by propagating their values over the fitting function, comparing the overall calibration uncertainties against reference values. We proposed four scenarios of uncertainty (from 0% to 10%) in the dose-ratio determination to evaluate its effect in the calibration process., Results: The manufacturing tolerance of the flattening filter (±0.035 mm) produces a change of 1.4% in the calculated HVL and a negligible effect over the Bw , (µen /ρ)water,air , and the overall calibration uncertainty. A potential variation of 14% of the electron energies due to manufacturing tolerances in the x-ray tube (69.5 ± ~10 keV) generates a variation of 10% in the HVL. However, this change has a negligible effect over the Bw and (µen /ρ)water,air , adding 0.1% to the overall calibration uncertainty. The fitting functions reproduce the data with an uncertainty (k = 2) below 1%, 0.5%, and 0.4% for the HVL, Bw , and (µen /ρ)water,air , respectively. The four studied absorbed dose-ratio uncertainty scenarios add, in the worst-case scenario, 0.2% to the overall uncertainty of the calibration process., Conclusions: This work shows the feasibility of using the absorbed depth-dose curve in the calibration of an eBT system with minimal loss of precision., (© 2019 American Association of Physicists in Medicine.)- Published
- 2020
- Full Text
- View/download PDF
10. GPU-accelerated bi-objective treatment planning for prostate high-dose-rate brachytherapy.
- Author
-
Bouter A, Alderliesten T, Pieters BR, Bel A, Niatsetski Y, and Bosman PAN
- Subjects
- Algorithms, Humans, Male, Radiotherapy Dosage, Brachytherapy, Computer Graphics, Prostatic Neoplasms radiotherapy, Radiation Dosage, Radiotherapy Planning, Computer-Assisted methods
- Abstract
Purpose: The purpose of this study is to improve upon a recently introduced bi-objective treatment planning method for prostate high-dose-rate (HDR) brachytherapy (BT), both in terms of resulting plan quality and runtime requirements, to the extent that its execution time is clinically acceptable., Methods: Bi-objective treatment planning is done using a state-of-the-art multiobjective evolutionary algorithm, which produces a large number of potential treatment plans with different trade-offs between coverage of the target volumes and sparing organs at risk. A graphics processing unit (GPU) is used for large-scale parallelization of dose calculations and the calculation of the dose-volume (DV) indices of potential treatment plans. Moreover, the objectives of the previously used bi-objective optimization model are modified to produce better results., Results: We applied the GPU-accelerated bi-objective treatment planning method to a set of 18 patients, resulting in a set containing a few hundred potential treatment plans with different trade-offs for each of these patients. Due to accelerations introduced in this article, results previously achieved after 1 hour are now achieved within 30 seconds of optimization. We found plans satisfying the clinical protocol for 15 of 18 patients, whereas this was the case for only 4 of 18 clinical plans. Higher quality treatment plans are obtained when the accuracy of DV index calculation is increased using more dose calculation points, requiring still no more than 3 minutes of optimization for 100 000 points., Conclusions: Large sets of high-quality treatment plans that trade-off coverage and sparing are now achievable within 30 seconds, due to the GPU-acceleration of a previously introduced bi-objective treatment planning method for prostate HDR brachytherapy. Higher quality plans can be achieved when optimizing for 3 minutes, which we still consider to be clinically acceptable. This allows for more insightful treatment plan selection in a clinical setting., (© 2019 American Association of Physicists in Medicine.)
- Published
- 2019
- Full Text
- View/download PDF
11. A Monte Carlo-based dosimetric characterization of Esteya ® , an electronic surface brachytherapy unit.
- Author
-
Valdes-Cortez C, Niatsetski Y, Perez-Calatayud J, Ballester F, and Vijande J
- Subjects
- Photons, Radiometry, Uncertainty, Brachytherapy, Monte Carlo Method
- Abstract
Purpose: The purpose of this work is threefold: First, to obtain the phase space of an electronic brachytherapy (eBT) system designed for surface skin treatments. Second, to explore the use of some efficiency enhancing (EFEN) strategies in the determination of the phase space. Third, to use the phase space previously obtained to perform a dosimetric characterization of the Esteya eBT system., Methods: The Monte Carlo study of the 69.5 kVp x-ray beam of the Esteya
® unit (Elekta Brachytherapy, Veenendaal, The Netherlands) was performed with PENELOPE2014. The EFEN strategies included the use of variance reduction techniques and mixed Class II simulations, where transport parameters were fine-tuned. Four source models were studied varying the most relevant parameters characterizing the electron beam impinging the target: the energy spectrum (mono-energetic or Gaussian shaped), and the electron distribution over the focal spot (uniform or Gaussian shaped). Phase spaces obtained were analyzed to detect differences in the calculated data due to the EFEN strategy or the source configuration. Depth dose curves and absorbed dose profiles were obtained for each source model and compared to experimental data previously published., Results: In our EFEN strategy, the interaction forcing variance reduction (VRIF) technique increases efficiency by a factor ~20. Tailoring the transport parameters values (C1 and C2) does not increase the efficiency in a significant way. Applying a universal cutoff energy EABS of 10 keV saves 84% of CPU time while showing negligible impact on the calculated results. Disabling the electron transport by imposing an electron energy cutoff of 70 keV (except for the target) saves an extra 8% (losing in the process 1.2% of the photons). The Gaussian energy source (FWHM = 10%, centered at the nominal kVp, homogeneous electron distribution) shows characteristic K-lines in its energy spectrum, not observed experimentally. The average photon energy using an ideal source (mono-energetic, homogeneous electron distribution) was 36.19 ± 0.09 keV, in agreement with the published measured data of 36.2 ± 0.2 keV. The use of a Gaussian-distributed electron source (mono-energetic) increases the penumbra by 50%, which is closer to the measurement results. The maximum discrepancy of the calculated percent depth dose with the corresponding measured values is 4.5% (at the phantom surface, less than 2% beyond 1 mm depth) and 5% (for the 80% of the field) in the dose profile. Our results agree with the findings published by other authors and are consistent within the expected Type A and B uncertainties., Conclusions: Our results agree with the published measurement results within the reported uncertainties. The observed differences in PDD, dose profiles, and photon spectrum come from three main sources of uncertainty: intermachine variations, measurements, and Monte Carlo calculations. It has been observed that a mono-energetic source with a Gaussian electron distribution over the focal spot is a suitable choice to reproduce the experimental data., (© 2018 American Association of Physicists in Medicine.)- Published
- 2019
- Full Text
- View/download PDF
12. Advanced Collapsed cone Engine dose calculations in tissue media for COMS eye plaques loaded with I-125 seeds.
- Author
-
Morrison H, Menon G, Larocque MP, van Veelen B, Niatsetski Y, Weis E, and Sloboda RS
- Subjects
- Algorithms, Computer Simulation, Eye Neoplasms diagnostic imaging, Female, Humans, Male, Models, Anatomic, Monte Carlo Method, Phantoms, Imaging, Radiometry, Tomography, X-Ray Computed, Water, Brachytherapy instrumentation, Brachytherapy methods, Eye diagnostic imaging, Eye radiation effects, Eye Neoplasms radiotherapy, Iodine Radioisotopes therapeutic use, Radiotherapy Dosage, Radiotherapy Planning, Computer-Assisted instrumentation, Radiotherapy Planning, Computer-Assisted methods
- Abstract
Purpose: To investigate the dose calculation accuracy of the Advanced Collapsed cone Engine (ACE) algorithm for ocular brachytherapy using a COMS plaque loaded with I-125 seeds for two heterogeneous patient tissue scenarios., Methods: The Oncura model 6711 I-125 seed and 16 mm COMS plaque were added to a research version (v4.6) of the Oncentra
® Brachy (OcB) treatment planning system (TPS) for dose calculations using ACE. Treatment plans were created for two heterogeneous cases: (a) a voxelized eye phantom comprising realistic eye materials and densities and (b) a patient CT dataset with variable densities throughout the dataset. ACE dose calculations were performed using a high accuracy mode, high-resolution calculation grid matching the imported CT datasets (0.5 × 0.5 × 0.5 mm3 ), and a user-defined CT calibration curve. The accuracy of ACE was evaluated by replicating the plan geometries and comparing to Monte Carlo (MC) calculated doses obtained using MCNP6. The effects of the heterogeneous patient tissues on the dose distributions were also evaluated by performing the ACE and MCNP6 calculations for the same scenarios but setting all tissues and air to water., Results: Average local percent dose differences between ACE and MC within contoured structures and at points of interest for both scenarios ranged from 1.2% to 20.9%, and along the plaque central axis (CAX) from 0.7% to 7.8%. The largest differences occurred in the plaque penumbra (up to 17%), and at contoured structure interfaces (up to 20%). Other regions in the eye agreed more closely, within the uncertainties of ACE dose calculations (~5%). Compared to that, dose differences between water-based and fully heterogeneous tissue simulations were up to 27%., Conclusions: Overall, ACE dosimetry agreed well with MC in the tumor volume and along the plaque CAX for the two heterogeneous tissue scenarios, indicating that ACE could potentially be used for clinical ocular brachytherapy dosimetry. In general, ACE data matched the fully heterogeneous MC data more closely than water-based data, even in regions where the ACE accuracy was relatively low. However, depending on the plaque position, doses to critical structures near the plaque penumbra or at tissue interfaces were less accurate, indicating that improvements may be necessary. More extensive knowledge of eye tissue compositions is still required., (© 2018 American Association of Physicists in Medicine.)- Published
- 2018
- Full Text
- View/download PDF
13. Initial evaluation of Advanced Collapsed cone Engine dose calculations in water medium for I-125 seeds and COMS eye plaques.
- Author
-
Morrison H, Menon G, Larocque MP, van Veelen B, Niatsetski Y, Weis E, and Sloboda RS
- Subjects
- Monte Carlo Method, Radiotherapy Dosage, Software, Eye Neoplasms radiotherapy, Iodine Radioisotopes therapeutic use, Melanoma radiotherapy, Radiation Dosage, Water
- Abstract
Purpose: To investigate the dose calculation accuracy in water medium of the Advanced Collapsed cone Engine (ACE) for three sizes of COMS eye plaques loaded with low-energy I-125 seeds., Methods: A model of the Oncura 6711 I-125 seed was created for use with ACE in Oncentra
® Brachy (OcB) using primary-scatter separated (PSS) point dose kernel and Task Group (TG) 43 datasets. COMS eye plaque models of diameters 12, 16, and 20 mm were introduced into the OcB applicator library based on 3D CAD drawings of the plaques and Silastic inserts. To perform TG-186 level 1 commissioning, treatment plans were created in OcB for a single source in water and for each COMS plaque in water for two scenarios: with only one centrally loaded seed, or with all seed positions loaded. ACE dose calculations were performed in high accuracy mode with a 0.5 × 0.5 × 0.5 mm3 calculation grid. The resulting dose data were evaluated against Monte Carlo (MC) calculated doses obtained with MCNP6, using both local and global percent differences., Results: ACE doses around the source for the single seed in water agreed with MC doses on average within < 5% inside a 6 × 6 × 6 cm3 region, and within < 1.5% inside a 2 × 2 × 2 cm3 region. The PSS data were generated at a higher resolution within 2 cm from the source, resulting in this improved agreement closer to the source due to fewer approximations in the ACE dose calculation. Average differences in both investigated plaque loading patterns in front of the plaques and on the plaque central axes were ≤ 2.5%, though larger differences (up to 12%) were found near the plaque lip., Conclusions: Overall, good agreement was found between ACE and MC dose calculations for a single I-125 seed and in front of the COMS plaques in water. More complex scenarios need to be investigated to determine how well ACE handles heterogeneous patient materials., (© 2018 American Association of Physicists in Medicine.)- Published