- Aged, Aged, 80 and over, Aortic Aneurysm, Abdominal diagnostic imaging, Aortic Aneurysm, Abdominal mortality, Aortic Aneurysm, Thoracic diagnostic imaging, Aortic Aneurysm, Thoracic mortality, Blood Vessel Prosthesis Implantation adverse effects, Blood Vessel Prosthesis Implantation mortality, Endoleak etiology, Endoleak therapy, Endovascular Procedures adverse effects, Endovascular Procedures mortality, Female, Humans, Male, Middle Aged, Prosthesis Design, Retreatment, Retrospective Studies, Time Factors, Treatment Outcome, Aortic Aneurysm, Abdominal surgery, Aortic Aneurysm, Thoracic surgery, Blood Vessel Prosthesis, Blood Vessel Prosthesis Implantation instrumentation, Endovascular Procedures instrumentation, Stents
- Abstract
Objective: Until today, no dedicated bridging stent graft (BSG) has been available for use in fenestrated and branched endovascular aneurysm repair (F/BEVAR). The purpose of this study was to evaluate the clinical performance of the well-known Advanta/iCast V12 (Getinge Maquet, Rastatt, Germany) and the new Viabahn VBX (W. L. Gore & Associates, Flagstaff, Ariz) balloon-expandable stent graft in F/BEVAR., Methods: Retrospective analysis of prospectively collected data was performed. Inclusion criteria were treatment with fenestrated or branched endografts for complex aortic diseases, implantation of at least one VBX stent graft as a BSG in one of the target vessels, and clinical or radiologic follow-up of 6 months. The primary end point of the study was technical success of all BSGs, defined as placement of the BSG in the desired position with absence of endoleak on final angiography. Secondary end points were freedom from perioperative major adverse events and freedom from reinterventions and mortality at 6 months. Procedural and postoperative data were analyzed., Results: Between December 2017 and July 2018, there were 50 patients (40 male; mean age, 71 years) included. A total of 145 VBX stent grafts were implanted, followed by 57 Advanta V12, 29 Viabahn, and 28 bare-metal stents. There were 126 branches (celiac trunk, 27; superior mesenteric artery, 25; renal arteries, 74) sealed exclusively with VBX. Technical success rate was 98.6%. There were six device-related reinterventions due to type IC endoleaks (n = 4), target vessel stenosis distal to the BSG, and stent graft occlusion in a left renal artery in one case. The perioperative and aneurysm-related mortality was 0%; the 6-month all-cause mortality was 2%., Conclusions: The used BSGs demonstrated promising preliminary results in F/BEVAR. Further evaluation is mandatory to determine durability of the VBX., (Copyright © 2019 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.)
- Published
- 2020
- Full Text
- View/download PDF