1. Thermal Performance Assessment of Insulated door by experiment
- Author
-
Hong Won-Hwa, Jang Cheol-Yong, Ahn Byung-Lip, and Kim Chi-Hoon
- Subjects
Glazing ,Energy loss ,Coating ,business.industry ,Thermal ,engineering ,Structural engineering ,engineering.material ,Air gap (plumbing) ,business ,Central region ,Building envelope ,Thermal break - Abstract
Currently, Exterior wall`s U-value about building envelope is 0.36 W/(Central Region), but window`s one is 2.1 W/ according to air gap of glazing, filling gas, coating and type of windows. The door"s one is 1.6~5.5 W/ depending on material and configuration of door. As such, energy loss per unit of door is considerably larger like windows. The door for the recognition was relatively low because energy loss through the door is relatively small compared to window area. In this paper, thermal performance was analyzed through simulation targeting the door which has thermal break that can improve the insulation performance and doesn`t have one. As a results of simulations, case1 was calculated as the average of 1.63 w/m2k and case 2 was calculated as the average of 4.14 w/m2k. The thermal performance of door depends on the type and condition of insulations. As a results of final simulations, Case1 was calculated as 1.06 w/m2k and Case2 was calculated as 1.27 w/m2k. As a results of the experiments, thermal performance of case 1 was measured as 1.28 w/m2k. Error between experiments and simulations is considered problems encountered when creating the samples. The effect of door frame on the overall thermal performance is slight because it`s a small proportion of the door frame.
- Published
- 2011