1. TCT-107 The DISCOVER Registry: 1 Year outcomes of a fully re-positionable and retrievable non-metallic transcatheter aortic valve in a real-world population
- Author
-
Fernando Gatto, Thierry Lefèvre, Ulrich Hink, Martine Gilard, Karl-Heinz Kuck, Antonio Colombo, Christoph Naber, Federico De Marco, Jan Van der Heyden, Christian Butter, Didier Tchetche, Guus R. G. Brueren, Smita Scholtz, Peter den Heijer, Dimitar Divchev, Wolfgang Schillinger, Azeem Latib, Federico M. Asch, Hüseyin Ince, Joachim Schofer, Peter Frambach, Giuseppe Bruschi, Stephan Kische, Daniel R. Wagner, Hervé Le Breton, Georg Nickenig, Laboratory of Cardiovascular Research, Centre de Recherche Public de la Santé, Division of Cardiology, Hôpital Minicipal et Clinique D'Eich-Centre Hospitalier du Luxembourg (CHL), Optimisation des régulations physiologiques (ORPHY (EA 4324)), Université de Brest (UBO)-Centre Hospitalier Régional Universitaire de Brest (CHRU Brest)-Institut Brestois Santé Agro Matière (IBSAM), Université de Brest (UBO)-Université de Brest (UBO), Département Electronique et Physique (TSP - EPH), Institut Mines-Télécom [Paris] (IMT)-Télécom SudParis (TSP), Laboratoire Traitement du Signal et de l'Image (LTSI), Université de Rennes (UR)-Institut National de la Santé et de la Recherche Médicale (INSERM), CHU Pontchaillou [Rennes], Département Electronique et Physique (EPH), Université de Rennes 1 (UR1), Université de Rennes (UNIV-RENNES)-Université de Rennes (UNIV-RENNES)-Institut National de la Santé et de la Recherche Médicale (INSERM), and Jonchère, Laurent
- Subjects
[SDV.IB] Life Sciences [q-bio]/Bioengineering ,Aortic valve ,medicine.medical_specialty ,Transcatheter aortic ,business.industry ,030204 cardiovascular system & hematology ,Direct flow ,03 medical and health sciences ,0302 clinical medicine ,medicine.anatomical_structure ,Internal medicine ,medicine ,Cardiology ,[SDV.IB]Life Sciences [q-bio]/Bioengineering ,030212 general & internal medicine ,Radiology ,Cardiology and Cardiovascular Medicine ,business ,ComputingMilieux_MISCELLANEOUS - Abstract
The Direct Flow Medical Trans-catheter Aortic Valve System has a non-metallic design with a pressurized support structure, which allows precise positioning, retrieval and full hemodynamic assessment of valve performance prior to permanent implantation. The DISCOVER registry is a European prospective
- Full Text
- View/download PDF