1. Comparison of 3D cellular imaging techniques based on scanned electron probes: Serial block face SEM vs. Axial bright-field STEM tomography
- Author
-
Jake D. Hoyne, Andrew A. Prince, Amith Rao, Irina D. Pokrovskaya, Alioscka A. Sousa, Maria A. Aronova, E.L. McBride, Qianping He, Guofeng Zhang, Gina N. Calco, Brian Storrie, Richard D. Leapman, and B.C. Kuo
- Subjects
0301 basic medicine ,Serial block-face scanning electron microscopy ,Blood Platelets ,Microscopy, Electron, Scanning Transmission ,Electron Microscope Tomography ,Materials science ,Cellular architecture ,Image processing ,Signal ,Article ,03 medical and health sciences ,030104 developmental biology ,Imaging, Three-Dimensional ,Electron tomography ,Structural Biology ,Scanning transmission electron microscopy ,Ultrastructure ,Image Processing, Computer-Assisted ,Humans ,Tomography ,Biomedical engineering - Abstract
Microscopies based on focused electron probes allow the cell biologist to image the 3D ultrastructure of eukaryotic cells and tissues extending over large volumes, thus providing new insight into the relationship between cellular architecture and function of organelles. Here we compare two such techniques: electron tomography in conjunction with axial bright-field scanning transmission electron microscopy (BF-STEM), and serial block face scanning electron microscopy (SBF-SEM). The advantages and limitations of each technique are illustrated by their application to determining the 3D ultrastructure of human blood platelets, by considering specimen geometry, specimen preparation, beam damage and image processing methods. Many features of the complex membranes composing the platelet organelles can be determined from both approaches, although STEM tomography offers a higher ∼3 nm isotropic pixel size, compared with ∼5 nm for SBF-SEM in the plane of the block face and ∼30 nm in the perpendicular direction. In this regard, we demonstrate that STEM tomography is advantageous for visualizing the platelet canalicular system, which consists of an interconnected network of narrow (∼50–100 nm) membranous cisternae. In contrast, SBF-SEM enables visualization of complete platelets, each of which extends ∼2 µm in minimum dimension, whereas BF-STEM tomography can typically only visualize approximately half of the platelet volume due to a rapid non-linear loss of signal in specimens of thickness greater than ∼1.5 µm. We also show that the limitations of each approach can be ameliorated by combining 3D and 2D measurements using a stereological approach.
- Published
- 2017