1. Assessing the precision of posttraumatic orbital reconstruction through 'mirror' orbital superimposition: A novel approach for testing the anatomical accuracy
- Author
-
Annalisa Cappella, Alberto Tagliaferri, Davide Sozzi, Alberto Bozzetti, Gabriele Canzi, Daniele Gibelli, Chiarella Sforza, Lorenzo Monticelli, Sozzi, D, Gibelli, D, Canzi, G, Tagliaferri, A, Monticelli, L, Cappella, A, Bozzetti, A, and Sforza, C
- Subjects
Adult ,Male ,Surface (mathematics) ,genetic structures ,Orbital fracture ,Maxillofacial surgery ,Geometry ,Root mean square ,Young Adult ,03 medical and health sciences ,Imaging, Three-Dimensional ,0302 clinical medicine ,Humans ,Medicine ,Superimposition ,RMS (root mean square) ,Asymmetry Index ,Orbital Fracture ,Orbital Fractures ,Aged ,Retrospective Studies ,3D segmentation ,business.industry ,Otorhinolaryngology2734 Pathology and Forensic Medicine ,030206 dentistry ,Middle Aged ,Plastic Surgery Procedures ,eye diseases ,Sagittal plane ,Titanium mesh ,Orbit ,medicine.anatomical_structure ,Otorhinolaryngology ,Orbital reconstruction ,030220 oncology & carcinogenesis ,Female ,Surgery ,Oral Surgery ,Tomography, X-Ray Computed ,business ,Mirroring - Abstract
Orbital reconstruction in cases of trauma is usually performed using the unaffected side orbital volume as a reference, but this measurement does not fully consider the anatomical characteristics of orbital surfaces. We propose a novel procedure based on the registration of 3D orbital segmented surfaces. Reconstructed orbits from 20 patients and healthy orbits from 13 control subjects were segmented from the post-operative CT-scans. The 3D orbital model from the unaffected orbit was “mirrored” according to the sagittal plane and superimposed onto the reconstructed one, with calculation of volumes, asymmetry index and point-to-point RMS (root mean square) distances. Inter- and intra-observer errors were tested through Bland–Altman plot. Differences in volume, asymmetry index and RMS value between the control group and the treated patients were assessed through two-way ANOVA and Student's t-test (p < 0.05). According to Bland–Altman test, intra- and inter-operator repeatability was respectively 87% and 89%. No significant differences in volume or asymmetry index between the control group and the treated patients were observed (p > 0.05), but the RMS value was significantly larger in the latter ones (on average, 0.90 ± 0.26 mm vs. 0.67 ± 0.17 mm, p < 0.05). Results show that the reconstructed orbits present a morphologically different surface from the unaffected ones.
- Published
- 2018
- Full Text
- View/download PDF