1. Development and validation of an UPLC-MS/MS assay for the simultaneous quantification of seven commonly used antibiotics in human plasma and its application in therapeutic drug monitoring.
- Author
-
Mekking XM, Velthoven-Graafland K, Teulen MJA, Brüggemann RJM, Te Brake LHM, and Jager NGL
- Subjects
- Humans, Ceftazidime, Chromatography, Liquid methods, Drug Monitoring methods, Reproducibility of Results, Liquid Chromatography-Mass Spectrometry, Tandem Mass Spectrometry methods, Piperacillin, Tazobactam, Ciprofloxacin, Trimethoprim, Sulfamethoxazole, Chromatography, High Pressure Liquid methods, Anti-Bacterial Agents, Floxacillin
- Abstract
Objective: To develop and validate an UPLC-MS/MS assay for simultaneous determination of the total concentration of ceftazidime, ciprofloxacin, flucloxacillin, piperacillin, tazobactam, sulfamethoxazole, N-acetyl sulfamethoxazole and trimethoprim, and the protein-unbound concentration of flucloxacillin, in human plasma to be used for research and clinical practice., Methods: Sample pretreatment included protein precipitation with methanol. For the measurement of protein-unbound flucloxacillin, ultrafiltration was performed at physiological temperature. For all compounds, a stable isotopically labelled internal standard was used. Reliability of the results was assessed by participation in an international quality control programme., Results: The assay was successfully validated according to the EMA guidelines over a concentration range of 0.5-100 mg/L for ceftazidime, 0.05-10 mg/L for ciprofloxacin, 0.4-125 mg/L for flucloxacillin, 0.2-60 mg/L for piperacillin, 0.15-30 mg/L for tazobactam, 1-200 mg/L for sulfamethoxazole and N-acetyl sulfamethoxazole, 0.05-10 mg/L for trimethoprim and 0.10-50 mg/L for unbound flucloxacillin. For measurement of total concentrations, the within- and between-day accuracy ranged from 90.0% to 109%, and 93.4% to 108%, respectively. Within- and between-day precision (variation coefficients, CVs) ranged from 1.70% to 11.2%, and 0.290% to 5.30%, respectively. For unbound flucloxacillin, within-day accuracy ranged from 103% to 106% and between-day accuracy from 102% to 105%. The within- and between-day CVs ranged from 1.92% to 7.11%. Results of the international quality control programme showed that the assay is reliable., Conclusions: The method provided reliable, precise and accurate measurement of seven commonly prescribed antibiotics, including the unbound concentration of flucloxacillin. This method is now routinely applied in research and clinical practice., (© The Author(s) 2024. Published by Oxford University Press on behalf of British Society for Antimicrobial Chemotherapy.)
- Published
- 2024
- Full Text
- View/download PDF