1. Biomechanical analysis of a transiliac internal fixator.
- Author
-
Dienstknecht T, Berner A, Lenich A, Zellner J, Mueller M, Nerlich M, Fuechtmeier B, Dienstknecht, Thomas, Berner, Arne, Lenich, Andreas, Zellner, Johannes, Mueller, Michael, Nerlich, Michael, and Fuechtmeier, Bernd
- Abstract
Purpose: We evaluated the biomechanical characteristics of the transiliac internal fixator (TIFI) as compared to two well-established methods of internal posterior pelvic ring fixation.Methods: Six freshly frozen human pelves were used for simulated single-leg stance loading of an AO type C injury model (pubic symphysis diastasis and unilateral sacroiliac joint disruption). The symphysis rupture was stabilized with a dynamic compression plate. Afterwards the three internal stabilization systems (TIFI, iliosacral screws and ventral plate osteosynthesis) were analysed. Fragment movement was measured in a contact-free manner with a stereophotometric infrared system.Results: No significant differences in the three-dimensional deformation tolerated by the TIFI as compared to the other internal fixation systems were found.Conclusions: The transiliac internal fixator provides the same biomechanical stability as the other reference implants tested. We suggest the use of this device as a suitable alternative to the other implants. [ABSTRACT FROM AUTHOR]- Published
- 2011
- Full Text
- View/download PDF