6 results on '"Edward W. Holt"'
Search Results
2. Su1441 Later Queue Position in the Endoscopy Schedule Is Independently Associated With Lower Detection of Right-Sided Polyps and Adenomas
- Author
-
Richard Sundberg, Hanley Ma, Michael S. Verhille, Kidist K. Yimam, Edward W. Holt, and Richard E. Shaw
- Subjects
Schedule ,medicine.medical_specialty ,medicine.diagnostic_test ,business.industry ,Gastroenterology ,Right-Sided ,Endoscopy ,Surgery ,Position (obstetrics) ,medicine ,Radiology, Nuclear Medicine and imaging ,Radiology ,business ,Queue - Published
- 2012
3. Sa1503 EUS-Based ERCP Reduces Risk Exposure in Pregnant Patients With Suspected Choledocholithiasis
- Author
-
Yasser M. Bhat, Steve Kane, Kenneth F. Binmoeller, Janak N. Shah, Sheba Vohra, and Edward W. Holt
- Subjects
Endoscopic ultrasound ,medicine.medical_specialty ,Common bile duct ,medicine.diagnostic_test ,Bile duct ,business.industry ,medicine.medical_treatment ,Gastroenterology ,Stent ,medicine.disease ,digestive system diseases ,Endoscopy ,medicine.anatomical_structure ,Fine-needle aspiration ,Biopsy ,medicine ,Pancreatitis ,Radiology, Nuclear Medicine and imaging ,Radiology ,business - Abstract
EUS-Based ERCP Reduces Risk Exposure in Pregnant Patients With Suspected Choledocholithiasis Sheba Vohra*, Edward W. Holt, Yasser M. Bhat, Janak N. Shah, Steve Kane, Kenneth F. Binmoeller Internal Medicine, California Pacific Medical Center, San Francisco, CA; Gastroenterology, California Pacific Medical Center, San Francisco, CA; Interventional Endoscopy Service, California Pacific Medical Center, San Francisco, CA Background: ERCP is routinely used to evaluate and treat suspected choledocholithiasis (CDL). However, in the pregnant patient, radiation exposure during ERCP poses a risk to the fetus. Endoscopic ultrasound (EUS) is highly sensitive in the detection of CDL, and is able to determine the size and number of stones. We evaluated the utility of EUS prior to ERCP in pregnant patients with suspected CDL. Aim: To determine if same-session EUS-based ERCP in pregnant patients with suspected CDL is associated with a reduction in ERCPrelated complications. Methods: We retrospectively identified pregnant patients referred to our center for suspected CDL between 2008 and 2011. EUS, using a curved linear array echoendoscope, was performed in all patients to confirm CDL and to determine the size and number of stones. Patients with confirmed CDL underwent ERCP, without fluoroscopy when possible. Deep selective bile duct cannulation was confirmed by aspiration of yellow bile and stone extraction was accomplished after sphincterotomy was performed. The number of extracted stones was counted and compared to the number of stones identified by EUS. Cholangioscopy was performed at the discretion of the endoscopist to confirm CBD clearance. Patient charts were reviewed to determine indications, procedure times, radiation use, clinical course and complications. Results: Ten pregnant women with suspected CDL were included in the study. The mean age was 30.7 years (range 20-40) and the mean gestation was 24 weeks (range 11-31). All 10 patients were symptomatic (acute abdominal pain 10, elevated transaminases 9, gallstone pancreatitis 3). Four patients had no evidence of stones at EUS and were managed conservatively with uneventful outcomes. Five patients with CDL and one patient with a pancreatic duct stone at EUS went on to same-session ERCP. In 4 of 5 patients with CDL, the number of stones extracted matched the number of stones seen at EUS. Cholangioscopy was used to clear the common bile duct in the patient with mismatched stone counts. The sixth patient with a pancreatic duct stone underwent stent placement with a 5 French stent. No fluoroscopy was used in 5 patients and a 1-second fluoroscopic image without radiograph was required in the patient with a pancreatic duct stone to confirm wire position prior to stent insertion. The average endoscopy time was 43 minutes for the ERCP group vs. 11 minutes for the EUS group (p 0.01). There were no complications in any of the cases. Conclusion: EUS prior to ERCP eliminated the need for ERCP and its attendant risks in 4 of 10 pregnant patients with suspected CDL. ERCP with stone extraction was successful without the use of fluoroscopy in all patients with bile duct stones. When available, same-session EUS should precede ERCP in the treatment of pregnant patients with suspected CDL. Sa1504 Endoscopic Ultrasound-Guided Fine Needle Aspiration and Biopsy (EUS-FNAB) Using a Novel 25-Gauge Core Biopsy Needle: Optimizing the Yield of Both Cytology and Histology Takuji Iwashita*, Yousuke Nakai, Jason B. Samarasena, Do Hyun Park, John G. Lee, Kenneth J. Chang H.H. Chao Comprehensive Digestive Disease Center, University of California, Irvine, Orange, CA Background: Novel 19 and 22-gauge core biopsy needles which feature a hollowed-out reverse bevel to trap core are now available. Based on initial publications on the 19-gauge core biopsy needle, the current “best practice” for high core acquisition is to utilize only 3-5 to-and-fro needle movements along with high suction (10cc). A new 25-gauge core biopsy needle (CBN25) has been developed. Whether this same FNAB technique is most effective for CBN25 is unknown. Aim: To determine the optimal FNAB technique to obtain core specimen and increase histological and cytological yields using CBN25. Patients and Methods: CBN25 was used for consecutive patients presenting with a solid lesion for EUS-FNA between May and October 2011. After EUS evaluation, the lesion was punctured using CBN25 with either one of two FNA techniques. In the first 3 months, 3-5 to-and-fro movements with 10cc-syringe suction (ST, standard technique) was used and in the latter 5 months 10-20 to-and-fro movements with minimal negative pressure by pulling the stylet slowly (MT, modified technique) was used. The specimen was expelled onto a glass slide and all visible core were placed in formalin after measurement of core specimen lengths. The remainder of the non-core specimen was submitted for cytology. Per protocol there was a 4-pass stopping rule which was salvaged using a standard 25 gauge FNA needle. Data was analyzed retrospectively. Results: 60 patients (21 female; median age 67.5 (range 35-90)) underwent EUS-FNAB using CBN25 with ST in 20 and MT in 40. Punctured lesions and final diagnoses are summarized in table 1 and 2. FNAB with CBN25 was successful in all cases. Median number of FNAB passes was 4 (range 3-4). A total of 236 passes using CBN25 was performed with ST in 80 passes and MT in 156 passes. The yield of visible core was 24% (19/80) in ST compared to 79% (123/156) in MT (P 0.001, t-test). The mean core length was 1.6 mm (SD, 1.7) in ST and 8.0 mm (SD, 9.0) in MT. (P 0.001). Among patients with a final diagnosis of a neoplastic lesion (59 patients), the yield of histological diagnosis was 55% (11/20) in ST as compared to 90% (35/39) in MT (P 0.01, Chi-squared test). The cytological yield showed a positive diagnosis in 70% (14/20) in ST as compared to 92% (36/39) in MT (P 0.05). Overall diagnostic yields were 75% (15/20) and 95% (37/39) in ST and MT, respectively (P 0.05). 7 patients had salvage FNA (4 positive, 3 false negative). No complications were seen in any of the patients. Conclusion: After technique modification, EUS-FNAB using CBN25 had a histologic yield of 90% and an overall diagnostic yield of 95%. This needle and technique appear optimum for EUS tissue acquisition.
- Published
- 2012
4. 440 Absolute Number of Adenomas Detected at Colonoscopy Represents the Preventive Capability of Colonoscopy More Accurately Than Adenoma Detection Rate
- Author
-
Hanley Ma, Edward W. Holt, Richard Sundberg, Kidist K. Yimam, Michael S. Verhille, and Richard E. Shaw
- Subjects
medicine.medical_specialty ,medicine.diagnostic_test ,Adenoma ,Absolute number ,business.industry ,General surgery ,Gastroenterology ,Colonoscopy ,medicine.disease ,Endoscopy ,Significant error ,medicine ,Radiology, Nuclear Medicine and imaging ,Radiology ,Detection rate ,business - Abstract
that could only have been obtained from ER. Overall, 65 % of significant findings were missed on the RR when the endoscopy report was not available in the EMR at the time of the RR, as compared to 25% when the ER was accessible at the time of the RR (OR 0.179, p 0.01). Conclusions: 1. Radiology interpretation of post ERCP spot films does not guide decision-making during this dynamic test and adds little to the endoscopists’ read of the study. 2. The significant error rate in RR is likely due to an interpretation based solely on spot films, whereas endoscopists have access to dynamic intraprocedural fluoroscopic and endoscopic images. 3. Radiologists have fewer discrepancies in their reads when the endoscopy report is accessible in the EMR at the time of their reads. Sensitiviy of Radiology Read Findings
- Published
- 2012
5. Tu1737 Patient Perception of Bowel Preparation for Colonoscopy Is Associated With the Quality of Preparation
- Author
-
Kidist K. Yimam, Richard Sundberg, Michael S. Verhille, Hanley Ma, Edward W. Holt, and Richard E. Shaw
- Subjects
medicine.medical_specialty ,medicine.diagnostic_test ,business.industry ,General surgery ,media_common.quotation_subject ,Gastroenterology ,Colonoscopy ,Patient perceptions ,Internal medicine ,medicine ,Bowel preparation ,Radiology, Nuclear Medicine and imaging ,Quality (business) ,business ,media_common - Published
- 2012
6. 910 A Prospective Study Evaluating the Association Between Timing and Quality of Bowel Preparation for Colonoscopy and Adenoma Detection Rate
- Author
-
Edward W. Holt, Michael S. Verhille, Richard Sundberg, Richard E. Shaw, Hanley Ma, and Kidist K. Yimam
- Subjects
medicine.medical_specialty ,medicine.diagnostic_test ,Adenoma ,business.industry ,Esophagogastroduodenoscopy ,General surgery ,medicine.medical_treatment ,Mortality rate ,Gastroenterology ,Colonoscopy ,medicine.disease ,Polypectomy ,Bowel preparation ,Medicine ,Pancreatitis ,Radiology, Nuclear Medicine and imaging ,business ,Prospective cohort study - Abstract
Complications of Gastrointestinal Endoscopy in 85,391 Procedures Alberto Espino*, Ximena Garcia, Macarena Mac-Namara, Hugo Richter, Fernando Pimentel, Francisco Biel, Camila Robles, Matias Callejas, Allan C. Sharp, Andres Donoso, Roberto Candia, Robinson G. Gonzalez, Nicolas Jarufe, Marco Arrese, Manuel Alvarez-Lobos, Oslando Padilla Gastroenterology, Pontifical Catholic University of Chile, Santiago, Chile; Digestive Surgery, Pontifical Catholic University of Chile, Santiago, Chile; The Digestive Endoscopy Center of University Clinical Hospital, Pontifical Catholic University of Chile, Santiago, Chile; Public Health, Pontifical Catholic University of Chile, Santiago, Chile Background: Complications are inherent to GI endoscopy (GIE) and do not necessarily imply endoscopist’s negligence. They may occur even using highest standards of practice. Objectives: To analyze the frequency and severity of complications occurring within 30 days after of the GIE at a single university hospital in Chile. Methods: We reviewed the records about patients who underwent GIE from January 2001 through May 2011. Results: A total of 85,391 GIE were evaluated. Procedures: 46,928 (55%) esophagogastroduodenoscopy (EGD); 27,993 (32.8%) diagnostic colonoscopies; 1427 (1.7%) polypectomies; and other procedures (hemostasis, variceal band ligation (VBL), foreign-body removal, dilation, stents, PEG, ERCP, EUS and double balloon endoscopy) 9043 (10.5%). A total of 299 complications were associated with GIE (59 % female, mean age 63 years, range 5 99). The overall complications rate was 0.35% (cardiopulmonary (CP) 0.1%, bleeding 0.07%, perforation 0.06%, infection 0.04%, pancreatitis 0.03% and other). The overall complication rate was higher in therapeutic procedures (TP) vs diagnostic procedures (DP) (2.7% v/s 0.16%, p 0.0001). The percentage of severe complications was higher in TP vs DP (52.3% vs 28.4%, p 0.0001). The overall complication rate for EGD was 0.14% (CP 0.07%, perforation 0.017%, bleeding 0.019%); diagnostic colonoscopy, 0.27% (CP 0.1%, perforation 0.06%, bleeding 0.02%); and polypectomy, 1.8% (CP 0.14%, perforation 0.28%, bleeding 0.98%). A total of 15 deaths occurred (overall rate 0.018%, 83% in TP). The overall mortality rate was higher in TP vs DP (0.2% v/s 0.003%, p 0.0001). The mortality rate for PEG was 0.7%; VBL 0.4%; ERCP 0.2%; diagnostic colonoscopy 0.004%; EGD 0.004%; and polypectomy 0%. Conclusions: GIE is associated with complications and mortality. The severity and risk of complications are higher in therapeutic procedures. These risks should be clearly explained to patients and their family before the procedure.
- Published
- 2012
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.