1. Which multi-attribute utility instruments are recommended for use in cost-utility analysis? A review of national health technology assessment (HTA) guidelines
- Author
-
Matthew Kennedy-Martin, Jan J. V. Busschbach, Tessa Kennedy-Martin, Kristina S. Boye, Michael Herdman, Wolfgang Greiner, Mandy van Reenen, Bernhard Slaap, and Psychiatry
- Subjects
Technology Assessment, Biomedical ,Computer science ,Cost-Benefit Analysis ,Health Status ,Economics, Econometrics and Finance (miscellaneous) ,Guidelines ,i11, i18 ,Technology assessment ,Pharmacoeconomics ,Utility ,Surveys and Questionnaires ,Humans ,Multi-attribute utility ,Economics, Pharmaceutical ,Health technology assessment ,Reimbursement ,Original Paper ,Cost–utility analysis ,Actuarial science ,Health economics ,Health Policy ,Cost-utility analysis ,Multi-attribute utility instruments ,Guideline ,Preference ,Quality of Life - Abstract
Background Several multi-attribute utility instruments (MAUIs) are available from which utilities can be derived for use in cost-utility analysis (CUA). This study provides a review of recommendations from national health technology assessment (HTA) agencies regarding the choice of MAUIs. Methods A list was compiled of HTA agencies that provide or refer to published official pharmacoeconomic (PE) guidelines for pricing, reimbursement or market access. The guidelines were reviewed for recommendations on the indirect calculation of utilities and categorized as: a preference for a specific MAUI; providing no MAUI preference, but providing examples of suitable MAUIs and/or recommending the use of national value sets; and recommending CUA, but not providing examples of MAUIs. Results Thirty-four PE guidelines were included for review. MAUIs named for use in CUA: EQ-5D (n = 29 guidelines), the SF-6D (n = 11), HUI (n = 10), QWB (n = 3), AQoL (n = 2), CHU9D (n = 1). EQ-5D was a preferred MAUI in 15 guidelines. Alongside the EQ-5D, the HUI was a preferred MAUI in one guideline, with DALY disability weights mentioned in another. Fourteen guidelines expressed no preference for a specific MAUI, but provided examples: EQ-5D (n = 14), SF-6D (n = 11), HUI (n = 9), QWB (n = 3), AQoL (n = 2), CHU9D (n = 1). Of those that did not specify a particular MAUI, 12 preferred calculating utilities using national preference weights. Conclusions The EQ-5D, HUI, and SF-6D were the three MAUIs most frequently mentioned in guidelines. The most commonly cited MAUI (in 85% of PE guidelines) was EQ-5D, either as a preferred MAUI or as an example of a suitable MAUI for use in CUA in HTA.
- Published
- 2020