4 results on '"Hernández-Romero I"'
Search Results
2. Standardized 2D atrial mapping and its clinical applications.
- Author
-
Wang T, Karel J, Invers-Rubio E, Hernández-Romero I, Peeters R, Bonizzi P, and Guillem MS
- Subjects
- Humans, Heart Atria diagnostic imaging, Atrial Fibrillation diagnostic imaging, Atrial Fibrillation surgery, Atrial Appendage, Catheter Ablation methods
- Abstract
The visualization and comparison of electrophysiological information in the atrium among different patients could be facilitated by a standardized 2D atrial mapping. However, due to the complexity of the atrial anatomy, unfolding the 3D geometry into a 2D atrial mapping is challenging. In this study, we aim to develop a standardized approach to achieve a 2D atrial mapping that connects the left and right atria, while maintaining fixed positions and sizes of atrial segments across individuals. Atrial segmentation is a prerequisite for the process. Segmentation includes 19 different segments with 12 segments from the left atrium, 5 segments from the right atrium, and two segments for the atrial septum. To ensure consistent and physiologically meaningful segment connections, an automated procedure is applied to open up the atrial surfaces and project the 3D information into 2D. The corresponding 2D atrial mapping can then be utilized to visualize different electrophysiological information of a patient, such as activation time patterns or phase maps. This can in turn provide useful information for guiding catheter ablation. The proposed standardized 2D maps can also be used to compare more easily structural information like fibrosis distribution with rotor presence and location. We show several examples of visualization of different electrophysiological properties for both healthy subjects and patients affected by atrial fibrillation. These examples show that the proposed maps provide an easy way to visualize and interpret intra-subject information and perform inter-subject comparison, which may provide a reference framework for the analysis of the atrial fibrillation substrate before treatment, and during a catheter ablation procedure., Competing Interests: Declaration of competing interest The authors declare the following financial interests/personal relationships which may be considered as potential competing interests: Maria S Guillem and Ismael Hernández-Romero are the shareholders and have received honoraria from Corify Care., (Copyright © 2023 The Authors. Published by Elsevier Ltd.. All rights reserved.)
- Published
- 2024
- Full Text
- View/download PDF
3. Analysis of the response of human iPSC-derived cardiomyocyte tissue to I CaL block. A combined in vitro and in silico approach.
- Author
-
Dasí A, Hernández-Romero I, Gomez JF, Climent AM, Ferrero JM, and Trenor B
- Subjects
- Action Potentials, Anti-Arrhythmia Agents, Computer Simulation, Humans, Myocytes, Cardiac, Induced Pluripotent Stem Cells
- Abstract
The high incidence of cardiac arrythmias underlines the need for the assessment of pharmacological therapies. In this field of drug efficacy, as in the field of drug safety highlighted by the Comprehensive in Vitro Proarrhythmia Assay initiative, new pillars for research have become crucial: firstly, the integration of in-silico experiments, and secondly the evaluation of fully integrated biological systems, such as human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs). In this study, we therefore aimed to combine in-vitro experiments and in-silico simulations to evaluate the antiarrhythmic effect of L-type calcium current (I
CaL ) block in hiPSC-CMs. For this, hiPSC-CM preparations were cultured and an equivalent virtual tissue was modeled. Re-entry patterns of electrical activation were induced and several biomarkers were obtained before and after ICaL block. The virtual hiPSC-CM simulations were also reproduced using a tissue composed of adult ventricular cardiomyocytes (hAdultV-CMs). The analysis of phases, currents and safety factor for propagation showed an increased size of the re-entry core when ICaL was blocked as a result of depressed cellular excitability. The bigger wavefront curvature yielded reductions of 12.2%, 6.9%, and 4.2% in the frequency of the re-entry for hiPSC-CM cultures, virtual hiPSC-CM, and hAdultV-CM tissues, respectively. Furthermore, ICaL block led to a 47.8% shortening of the vulnerable window for re-entry in the virtual hiPSC-CM tissue and to re-entry vanishment in hAdultV-CM tissue. The consistent behavior between in-vitro and in-silico hiPSC-CMs and between in-silico hiPSC-CMs and hAdultV-CMs evidences that virtual hiPSC-CM tissues are suitable for assessing cardiac efficacy, as done in the present study through the analysis of ICaL block., (Copyright © 2021 The Author(s). Published by Elsevier Ltd.. All rights reserved.)- Published
- 2021
- Full Text
- View/download PDF
4. Automatic quality electrogram assessment improves phase-based reentrant activity identification in atrial fibrillation.
- Author
-
Costoya-Sánchez A, Climent AM, Hernández-Romero I, Liberos A, Fernández-Avilés F, Narayan SM, Atienza F, Guillem MS, and Rodrigo M
- Subjects
- Algorithms, Electrophysiologic Techniques, Cardiac, Humans, Atrial Fibrillation diagnosis
- Abstract
Identification of reentrant activity driving atrial fibrillation (AF) is increasingly important to ablative therapies. The goal of this work is to study how the automatically-classified quality of the electrograms (EGMs) affects reentrant AF driver localization. EGMs from 259 AF episodes obtained from 29 AF patients were recorded using 64-poles basket catheters and were manually classified according to their quality. An algorithm capable of identifying signal quality was developed using time and spectral domain parameters. Electrical reentries were identified in 3D phase maps using phase transform and were compared with those obtained with a 2D activation-based method. Effect of EGM quality was studied by discarding 3D phase reentries detected in regions with low-quality EGMs. Removal of reentries identified by 3D phase analysis in regions with low-quality EGMs improved its performance, increasing the area under the ROC curve (AUC) from 0.69 to 0.80. The EGMs quality classification algorithm showed an accurate performance for EGM classification (AUC 0.94) and reentry detection (AUC 0.80). Automatic classification of EGM quality based on time and spectral signal parameters is feasible and accurate, avoiding the manual labelling. Discard of reentries identified in regions with automatically-detected poor-quality EGMs improved the specificity of the 3D phase-based method for AF driver identification., (Copyright © 2019 Elsevier Ltd. All rights reserved.)
- Published
- 2020
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.