1. Numerical modeling of pulsatile blood flow through a mini-oxygenator in artificial lungs.
- Author
-
Tang TQ, Hsu SY, Dahiya A, Soh CH, and Lin KC
- Subjects
- Equipment Design, Humans, Hydrodynamics, Lung, Pulsatile Flow, Oxygen, Oxygenators, Membrane
- Abstract
While previous in vitro studies showed divergent results concerning the influence of pulsatile blood flow on oxygen advection in oxygenators, no study was done to investigate the uncertainty affected by blood flow dynamics. The aim of this study is to utilize a computational fluid dynamics model to clarify the debate concerning the influence of pulsatile blood flow on the oxygen transport. The computer model is based on a validated 2D finite volume approach that predicts oxygen transfer in pulsatile blood flow passing through a 300-micron hollow-fiber membrane bundle with a length of 254 mm, a building block for an artificial lung device. In this study, the flow parameters include the steady Reynolds number (Re = 2, 5, 10 and 20), Womersley parameter (Wo = 0.29, 0.38 and 0.53) and sinusoidal amplitude (A = 0.25, 0.5 and 0.75). Specifically, the computer model is extended to verify, for the first time, the previously measured O
2 transport that was observed to be hindered by pulsating flow in the Biolung, developed by Michigan Critical Care Consultants. A comprehensive analysis is carried out on computed profiles and fields of oxygen partial pressure (PO2 ) and oxygen saturation (SO2 ) as a function of Re, Wo and A. Based on the present results, we observe the positive and negative effects of pulsatile flow on PO2 at different blood flow rates. Besides, the SO2 variation is not much influenced by the pulsatile flow conditions investigated. While being consistent with a recent experimental study, the computed O2 volume flow rate is found to be increased at high blood flow rates operated with low frequency and high amplitude. Furthermore, the present study qualitatively explains that divergent outcomes reported in previous in vitro experimental studies could be owing to the different blood flow rates adopted. Finally, the contour analysis reveals how the spatial distributions of PO2 and SO2 vary over time., Competing Interests: Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper., (Copyright © 2021. Published by Elsevier B.V.)- Published
- 2021
- Full Text
- View/download PDF