1. Dual Isotope SPECT Study With Epilepsy Patients Using Semiconductor SPECT System
- Author
-
Takuya Toyonaga, Kotarou Sakurai, Tsugiko Kurita, Wataru Takeuchi, Tohru Shiga, Atsuro Suzuki, Naoki Kubo, Kenji Hirata, Chietsugu Katoh, Keiji Kobashi, and Nagara Tamaki
- Subjects
Adult ,Male ,Organotechnetium Compounds ,030218 nuclear medicine & medical imaging ,law.invention ,Iodine Radioisotopes ,03 medical and health sciences ,Epilepsy ,0302 clinical medicine ,law ,Dual isotope ,Medicine ,Humans ,Radiology, Nuclear Medicine and imaging ,Gamma Cameras ,Cysteine ,Tomography, Emission-Computed, Single-Photon ,business.industry ,Brain ,Collimator ,General Medicine ,medicine.disease ,Semiconductors ,Female ,business ,Nuclear medicine ,030217 neurology & neurosurgery - Abstract
We developed a prototype CdTe SPECT system with 4-pixel matched collimator for brain study. This system provides high-energy-resolution (6.6%), high-sensitivity (220 cps/MBq/head), and high-spatial-resolution images. The aim of this study was to evaluate dual-isotope study of CBF and central benzodiazepine receptor (BZR) images using Tc-ECD and I-IMZ with the new SPECT system in patients with epilepsy comparing with single-isotope study using the conventional scintillation gamma camera.This study included 13 patients with partial epilepsy. The BZR images were acquired at 3 hours after I-IMZ injection for 20 minutes. The images of IMZ were acquired with a conventional 3-head scintillation gamma camera. After BZR image acquisition with the conventional camera, Tc-ECD was injected, and CBF and BZR images were acquired simultaneously 5 minutes after ECD injection with the new SPECT system. The CBF images were also acquired with the conventional camera on separate days. The findings were visually analyzed, and 3D-SSP maximum Z scores of lesions were compared between the 2 studies.There were 47 abnormal lesions on BZR images and 60 abnormal lesions on CBF images in the single-isotope study with the conventional camera. Dual-isotope study with the new system showed concordant abnormal findings of 46 of 47 lesions on BZR and 54 of 60 lesions on CBF images with the single-isotope study with the conventional camera. There was high agreement between the 2 studies in both BZR and CBF findings (Cohen κ values = 0.96 for BZR and 0.78 for CBF). In semiquantitative analysis, maximum Z scores of dual-isotope study with the new system strongly correlated with those of single-isotope study with the conventional camera (BZR: r = 0.82, P0.05, CBF: r = 0.87, P0.05).Our new SPECT system permits dual-isotope study for pixel-by-pixel analysis of CBF and BZR information with the same pathophysiological condition in patients with epilepsy.
- Published
- 2017