1. The Immunoglobulin M-Shed Acute Phase Antigen (SAPA)-test for the Early Diagnosis of Congenital Chagas Disease in the Time of the Elimination Goal of Mother-to-Child Transmission.
- Author
-
Castro-Sesquen YE, Tinajeros F, Bern C, Galdos-Cardenas G, Malaga ES, Valencia Ayala E, Hjerrild K, Clipman SJ, Lescano AG, Bayangos T, Castillo W, Menduiña MC, Talaat KR, and Gilman RH
- Subjects
- Antibodies, Protozoan, Bolivia, Early Diagnosis, Female, Goals, Humans, Immunoglobulin M, Infant, Infant, Newborn, Infectious Disease Transmission, Vertical, Pregnancy, Chagas Disease diagnosis, Trypanosoma cruzi
- Abstract
Background: Diagnosis of congenital Chagas disease (CChD) in most endemic areas is based on low-sensitive microscopy at birth and 9-month immunoglobulin G (IgG), which has poor adherence. We aim to evaluate the accuracy of the Immunoglobulin M (IgM)-Shed Acute Phase Antigen (SAPA) test in the diagnosis of CChD at birth., Methods: Two cohort studies (training and validation cohorts) were conducted in 3 hospitals in the department of Santa Cruz, Bolivia. Pregnant women were screened for Chagas disease, and all infants born to seropositive mothers were followed for up to 9 months to diagnose CChD. A composite reference standard was used to determine congenital infection and was based on the parallel use of microscopy, quantitative polymerase chain reaction (qPCR), and IgM-trypomastigote excreted-secreted antigen (TESA) blot at birth and/or 1 month, and/or the detection of anti-Trypanosoma cruzi IgG at 6 or 9 months. The diagnostic accuracy of the IgM-SAPA test was calculated at birth against the composite reference standard., Results: Adherence to the 6- or 9-month follow-up ranged from 25.3% to 59.7%. Most cases of CChD (training and validation cohort: 76.5% and 83.7%, respectively) were detected during the first month of life using the combination of microscopy, qPCR, and/or IgM-TESA blot. Results from the validation cohort showed that when only 1 infant sample obtained at birth was evaluated, the qPCR and the IgM-SAPA test have similar accuracy (sensitivity: range, 79.1%-97.1% and 76.7%-94.3%, respectively, and specificity: 99.5% and 92.6%, respectively)., Conclusions: The IgM-SAPA test has the potential to be implemented as an early diagnostic tool in areas that currently rely only on microscopy., (© The Author(s) 2020. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.)
- Published
- 2021
- Full Text
- View/download PDF