1. Early markers of myocardial injury: cTnI is enough
- Author
-
Ilva, Tuomo, Lund, Juha, Porela, Pekka, Mustonen, Harri, Voipio-Pulkki, Liisa-Maria, Eriksson, Susann, Pettersson, Kim, Tanner, Pirjo, and Pulkki, Kari
- Subjects
- *
MYOCARDIUM , *FATTY acid-binding proteins , *MYOCARDIAL infarction , *ADVERSE health care events , *HEART disease prognosis , *BIOMARKERS , *PATIENTS , *WOUNDS & injuries ,MYOCARDIAL infarction diagnosis - Abstract
Abstract: Background: We compared the early diagnostic and prognostic performance of a highly sensitive cardiac troponin I (cTnI) assay with heart-type fatty acid binding protein (H-FABP), in the early hours of acute coronary syndrome. Methods: Serum samples of 293 patients were studied using the Abbott Architect cTnI assay and the H-FABP assay. Special attention was paid to the diagnostic and prognostic value of admission blood samples taken <24 h after symptom onset. The prognostic endpoint was total mortality and reinfarction at 6 months. Results: To detect forthcoming myocardial injury, admission samples gave receiver operating curve (ROC) areas (AUC) of 0.908 for cTnI and 0.855 for H-FABP (p =0.068) when the delay from symptom onset was <6 h (60.4% of all patients). When the delay was 6–24 h, the corresponding AUC values were 0.995 for cTnI and 0.849 for H-FABP (p =0.002). In multivariate analysis cTnI but not H-FABP predicted adverse events in all 293 patients (RR 3.02, 95% CI 1.62–5.63) and in those with delays <6 h (RR 2.92, 95% CI 1.47–5.81). Conclusion: In the era of highly sensitive cTnI assays, H-FABP appears to give no additional information even in patients who present within the first 6 h after acute MI. [Copyright &y& Elsevier]
- Published
- 2009
- Full Text
- View/download PDF