1. Improving the Diagnostic Performance of
- Author
-
Laurens E, Swart, Anna, Gomes, Asbjørn M, Scholtens, Bhanu, Sinha, Wilco, Tanis, Marnix G E H, Lam, Maureen J, van der Vlugt, Sebastian A F, Streukens, Erik H J G, Aarntzen, Jan, Bucerius, Sander, van Assen, Chantal P, Bleeker-Rovers, Peter Paul, van Geel, Gabriel P, Krestin, Joost P, van Melle, Jolien W, Roos-Hesselink, Riemer H J A, Slart, Andor W J M, Glaudemans, and Ricardo P J, Budde
- Subjects
Adult ,Heart Valve Prosthesis Implantation ,Male ,Observer Variation ,Prosthesis-Related Infections ,Reproducibility of Results ,Endocarditis, Bacterial ,Middle Aged ,Heart Valves ,Severity of Illness Index ,Treatment Outcome ,Fluorodeoxyglucose F18 ,Predictive Value of Tests ,Risk Factors ,Heart Valve Prosthesis ,Positron Emission Tomography Computed Tomography ,Humans ,Female ,Radiopharmaceuticals ,Aged ,Netherlands ,Retrospective Studies - Abstract
In this multicenter study, 160 patients with a prosthetic heart valve (median age, 62 years [43-73]; 68% male; 82 mechanical valves; 62 biological; 9 transcatheter aortic valve replacements; 7 other) who underwent FDG PET/CT for suspicion of PVE, and 77 patients with a PV (median age, 73 years [65-77]; 71% male; 26 mechanical valves; 45 biological; 6 transcatheter aortic valve replacements) who underwent FDG PET/CT for other indications (negative control group), were retrospectively included. Their scans were reassessed by 2 independent observers blinded to all clinical data, both visually and quantitatively on available European Association of Nuclear Medicine Research Ltd-standardized reconstructions. Confounders were identified by use of a logistic regression model and subsequently excluded.Visual assessment of FDG PET/CT had a sensitivity/specificity/positive predictive value/negative predictive value for PVE of 74%/91%/89%/78%, respectively. Low inflammatory activity (C-reactive protein40 mg/L) at the time of imaging and use of surgical adhesives during prosthetic heart valve implantation were significant confounders, whereas recent valve implantation was not. After the exclusion of patients with significant confounders, diagnostic performance values of the visual assessment increased to 91%/95%/95%/91%. As a semiquantitative measure of FDG uptake, a European Association of Nuclear Medicine Research Ltd-standardized uptake value ratio of ≥2.0 was a 100% sensitive and 91% specific predictor of PVE.Both visual and quantitative assessments of FDG PET/CT have a high diagnostic accuracy in patients in whom PVE is suspected. FDG PET/CT should be implemented early in the diagnostic workup to prevent the negative confounding effects of low inflammatory activity (eg, attributable to prolonged antibiotic therapy). Recent valve implantation was not a significant predictor of false-positive interpretations, but surgical adhesives used during implantation were.
- Published
- 2018