1. Combined Vascular and Orthopaedic Approach for a Pseudotumor Causing Deep Vein Thrombosis after Metal-on-Metal Hip Resurfacing Arthroplasty
- Author
-
Abdel-Hamid, Hossam, Miles, Jonathan, Carrington, Richard W. J., Hart, Alister, Loh, Alex, and Skinner, John A.
- Subjects
Article Subject - Abstract
Introduction. Metal-on-metal (MoM) hip resurfacings have been associated with a variety of complications resulting from adverse reaction to metal debris. Pseudotumors have rarely been reported to cause deep venous thrombosis (DVT). Study Design. A case report and a review of the literature. Case Presentation. A 75-year-old female who had left metal-on-metal hip resurfacing 6 years ago presented with left groin pain associated with unilateral lower limb edema and swelling. By duplex and MRI studies, our patient had an extensive soft tissue necrosis associated with a large pelvic mass causing extensive DVT of the lower limb secondary to mechanical compression of the left iliac vein. Results. Our case was initially treated for DVT followed by dual surgical approach. The pseudotumor was excised through a separate iliofemoral approach and revision of the hip implant was undertaken through a posterior approach in the same setting. An inferior vena cava (IVC) filter was inserted to minimise the perioperative risks of handling the iliac veins. Conclusion. A combined approach with vascular surgeons is required. Combined resection of the pseudotumor and revision of the metal bearing surfaces is essential, in order to achieve a good surgical outcome in this rare complication.
- Published
- 2015
- Full Text
- View/download PDF