1. In-Hospital Outcomes and Predictors of Paravalvular Leak and Deep Implantation With the Evolut R 34-mm Device: A Comparison With Smaller Evolut R Sizes
- Author
-
Andrea Garatti, Elena Acerbi, Omar Alessandro Oliva, Andrea Arneri, Nedy Brambilla, Francesco Bedogni, Maurizio Tusa, Luca Testa, Mauro Agnifili, Giovanni Bianchi, Riccardo Gorla, and Federico De Marco
- Subjects
Male ,Transcatheter aortic ,medicine.medical_treatment ,030204 cardiovascular system & hematology ,Prosthesis Design ,Body weight ,Transcatheter Aortic Valve Replacement ,03 medical and health sciences ,Postoperative Complications ,0302 clinical medicine ,Valve replacement ,Risk Factors ,medicine.artery ,Humans ,Medicine ,Ventricular outflow tract ,030212 general & internal medicine ,Paravalvular leak ,Retrospective Studies ,Aorta ,Ejection fraction ,business.industry ,Aortic Valve Stenosis ,General Medicine ,Hospitals ,Treatment Outcome ,Hospital outcomes ,Aortic Valve ,Heart Valve Prosthesis ,Cardiology and Cardiovascular Medicine ,business ,Nuclear medicine - Abstract
To compare in-hospital outcome of Evolut-R 34 mm vs. smaller Evolut-R devices and to identify predictors of paravalvular leak (PVL) and deep implantation specific for Evolut-R 34 mm.This single-center retrospective study included 359 consecutive patients undergoing transcatheter aortic valve replacement (TAVR) with Evolut-R 34 mm (N = 84,23.4%) and Evolut-R 23/26/29 mm (N = 275,76.6%) between 2016 and 2019.Patients in Evolut-R 34 mm group were more frequently males, had lower STS score, ejection fraction, and mean aortic gradient compared to the Evolut-R 23/26/29 mm group. Horizontal aorta and large LVOT were more frequent findings in the Evolut-R 34 mm group, whereas calcium volume was comparable among the groups. During TAVR, mean implantation depth and contrast volume were greater in the Evolut-R 34 mm group, compared to the Evolut 23/26/29 mm group. Post-procedurally, 30-day mortality, ≥moderate PVL, device success and pacemaker implantation (PM) rates were comparable between groups. Among independent predictors of ≥moderate PVL, calcium volume (OR:1.04; p0.001) was predictive with different thresholds in both groups, whereas aortic angulation (OR:1.40; p = 0.005) was predictive only in Evolut-R 34 mm group at a cutoff of 60° (AUC:0.73; p = 0.043). Body weight (OR:1.03; p = 0.027), left ventricular outflow tract (LVOT) diameter (OR:1.34; p = 0.001), and mean aortic gradient (OR:0.96; p = 0.006) were independent predictors of deep implantation (mean depth ≥ 6 mm), with LVOT27 mm being predictive specifically for Evolut-R 34 mm (AUC:0.66; p = 0.024).TAVR with Evolut-R 34 mm and Evolut-R 23/26/29 mm showed comparable in-hospital outcome. Aortic angulation60° and LVOT27 mm were predictive respectively of ≥moderate PVL and deep implantation specifically in Evolut-R 34 mm patients.
- Published
- 2022