1. Visualization of wrist ligaments with 3D and 2D magnetic resonance imaging at 3 Tesla
- Author
-
Rana Ab-Fawaz, Ingvar Kristiansson, Isabella M. Björkman-Burtscher, Björn Lundin, Mats Geijer, Simon Götestrand, and Anders Björkman
- Subjects
Adult ,Male ,Triangular Fibrocartilage ,Wrist Joint ,Wrist ,030218 nuclear medicine & medical imaging ,Young Adult ,03 medical and health sciences ,Imaging, Three-Dimensional ,0302 clinical medicine ,medicine ,Humans ,Radiology, Nuclear Medicine and imaging ,Prospective Studies ,030222 orthopedics ,Radiological and Ultrasound Technology ,medicine.diagnostic_test ,business.industry ,Magnetic resonance imaging ,General Medicine ,Anatomy ,Middle Aged ,Scapholunate ligament ,Lunotriquetral ligament ,Magnetic Resonance Imaging ,Visualization ,medicine.anatomical_structure ,Ligaments, Articular ,Female ,business ,Triangular Fibrocartilage Complex - Abstract
Background Wrist ligaments are challenging to visualize using magnetic resonance imaging (MRI). Injuries involving the scapholunate ligament (SLL), the lunotriquetral ligament (LTL), and the triangular fibrocartilage complex (TFCC) are common and difficult to diagnose, often requiring diagnostic arthroscopy. Purpose To compare the visualization of wrist ligaments on a three-dimensional (3D) sequence with two-dimensional (2D) sequences on 3-T MRI. Material and Methods Eighteen healthy volunteers were examined with a 3D SPACE (sampling perfection with application optimized contrasts using different flip angle evolution) sequence and 2D coronal, axial, and sagittal proton density-weighted (PD) sequences. Four musculoskeletal radiologists graded the anatomical visibility of the SLL, LTL, TFCC, and the image quality, using five grades in a visual grading characteristics (VGC) evaluation. After Bonferroni correction, a P value ≤0.005 was considered statistically significant. Results The 3D images were graded significantly better than the 2D images in the visualization of the dorsal and palmar parts of the SLL and the LTL. Regarding the TFCC, the 3D images were graded significantly better for visualization of the foveal attachment. 2D imaging was not found significantly superior to 3D imaging in any aspect. Conclusion The 3D SPACE sequence was scored as superior to the 2D sequences at 3 T in the assessment of the SLL, the LTL, and the foveal attachment of the TFCC. Thus, 3D SPACE can replace 2D PD sequences when these ligaments need to be assessed.
- Published
- 2021
- Full Text
- View/download PDF