1. Performance Characteristics of the NeuroEXPLORER, a Next-Generation Human Brain PET/CT Imager.
- Author
-
Li, Hongdi, Li, Hongdi, Badawi, Ramsey, Cherry, Simon, Fontaine, Kathryn, He, Liuchun, Henry, Shannan, Hillmer, Ansel, Hu, Lingzhi, Khattar, Nikkita, Leung, Edwin, Li, Tiantian, Li, Yusheng, Liu, Chi, Liu, Peng, Lu, Zhenrui, Majewski, Stanislaw, Matuskey, David, Morris, Evan, Mulnix, Tim, Omidvari, Negar, Samanta, Suranjana, Selfridge, Aaron, Sun, Xishan, Toyonaga, Takuya, Volpi, Tommaso, Zeng, Tianyi, Jones, Terry, Qi, Jinyi, Carson, Richard, Li, Hongdi, Li, Hongdi, Badawi, Ramsey, Cherry, Simon, Fontaine, Kathryn, He, Liuchun, Henry, Shannan, Hillmer, Ansel, Hu, Lingzhi, Khattar, Nikkita, Leung, Edwin, Li, Tiantian, Li, Yusheng, Liu, Chi, Liu, Peng, Lu, Zhenrui, Majewski, Stanislaw, Matuskey, David, Morris, Evan, Mulnix, Tim, Omidvari, Negar, Samanta, Suranjana, Selfridge, Aaron, Sun, Xishan, Toyonaga, Takuya, Volpi, Tommaso, Zeng, Tianyi, Jones, Terry, Qi, Jinyi, and Carson, Richard
- Abstract
The collaboration of Yale, the University of California, Davis, and United Imaging Healthcare has successfully developed the NeuroEXPLORER, a dedicated human brain PET imager with high spatial resolution, high sensitivity, and a built-in 3-dimensional camera for markerless continuous motion tracking. It has high depth-of-interaction and time-of-flight resolutions, along with a 52.4-cm transverse field of view (FOV) and an extended axial FOV (49.5 cm) to enhance sensitivity. Here, we present the physical characterization, performance evaluation, and first human images of the NeuroEXPLORER. Methods: Measurements of spatial resolution, sensitivity, count rate performance, energy and timing resolution, and image quality were performed adhering to the National Electrical Manufacturers Association (NEMA) NU 2-2018 standard. The systems performance was demonstrated through imaging studies of the Hoffman 3-dimensional brain phantom and the mini-Derenzo phantom. Initial 18F-FDG images from a healthy volunteer are presented. Results: With filtered backprojection reconstruction, the radial and tangential spatial resolutions (full width at half maximum) averaged 1.64, 2.06, and 2.51 mm, with axial resolutions of 2.73, 2.89, and 2.93 mm for radial offsets of 1, 10, and 20 cm, respectively. The average time-of-flight resolution was 236 ps, and the energy resolution was 10.5%. NEMA sensitivities were 46.0 and 47.6 kcps/MBq at the center and 10-cm offset, respectively. A sensitivity of 11.8% was achieved at the FOV center. The peak noise-equivalent count rate was 1.31 Mcps at 58.0 kBq/mL, and the scatter fraction at 5.3 kBq/mL was 36.5%. The maximum count rate error at the peak noise-equivalent count rate was less than 5%. At 3 iterations, the NEMA image-quality contrast recovery coefficients varied from 74.5% (10-mm sphere) to 92.6% (37-mm sphere), and background variability ranged from 3.1% to 1.4% at a contrast of 4.0:1. An example human brain 18F-FDG image exhibited very high r
- Published
- 2024