1. Environmentally friendly screen-printed electrodes for the selective detection of 4-bromo-2,5-dimethoxyphenethylamine (2C-B) in forensic analysis.
- Author
-
Macedo AA, Pimentel DM, Melo LMA, Rocha CM, de Fátima Â, Souza KAO, Costa JL, Arantes LC, and Dos Santos WTP
- Subjects
- Humans, Graphite chemistry, Limit of Detection, Chitosan chemistry, Substance Abuse Detection methods, Substance Abuse Detection instrumentation, Electrodes, Electrochemical Techniques methods, Electrochemical Techniques instrumentation, Dimethoxyphenylethylamine analogs & derivatives, Dimethoxyphenylethylamine analysis, Dimethoxyphenylethylamine chemistry
- Abstract
In response to the growing need for sustainable analytical methods, this study explores the repurposing of screen-printed electrodes (SPEs) that would otherwise be discarded. This involves recoating the working electrode surface with a graphite (Gr) and chitosan (CTS) dispersion, creating a reusable SPE (SPE-Gr/CTS). Demonstrating its utility, SPE-Gr/CTS was employed for the detection of 4-bromo-2,5-dimethoxyphenethylamine (2C-B), a phenylethylamine commonly used for recreational proposes. Identifying 2C-B in fluid oral and seized samples is of great interest for forensic and toxicological applications. The 2C-B detection using SPE-Gr/CTS was optimized in Britton-Robinson buffer solution (0.1 mol L
-1 ) at pH 2.0, employing square-wave adsorptive stripping voltammetry. The electrochemical behavior of 2C-B on SPE-Gr/CTS exhibited one irreversible oxidation and a reversible redox process. The proposed method presented a dynamic linear range for 2C-B determination (0.05 to 7.5 μmol L-1 ) with a low LOD (0.015 μmol L-1 ). Moreover, the stability of 2C-B electrochemical responses on SPE-Gr/CTS was confirmed using the same or different electrodes ( N = 3), with a relative standard deviation of less than 5.0%. Interference studies with seventeen other illicit drugs and adulterants demonstrated that the proposed method is selective for 2C-B detection even in the presence of these substances. Real seized and oral fluid samples containing 2C-B were analyzed using this method, and the results were confirmed by LC-MS. The proposed device demonstrates to be an environmentally friendly and selective sensor for 2C-B detection in forensic analysis, offering a rapid and straightforward screening method for seized and biological samples. In addition, a portable and sensitive determination of 2C-B in forensic samples is presented with minimal sample consumption (50 μL).- Published
- 2024
- Full Text
- View/download PDF