1. Detecting the therapeutic drugs in blood samples through PDMS-printed paper spray mass spectrometry.
- Author
-
Xiong L, Sun S, Lu X, Wang X, Yu Q, and Qian X
- Subjects
- Humans, Limit of Detection, Clozapine blood, Risperidone blood, Quetiapine Fumarate blood, Paliperidone Palmitate blood, Olanzapine blood, Psychotropic Drugs blood, Printing, Paper, Dimethylpolysiloxanes chemistry, Mass Spectrometry methods
- Abstract
In this paper, paper microfluidic channel fabricated by directly screen-printing of polydimethylsiloxane (PDMS) is proposed for paper spray mass spectrometry analysis of therapeutic drugs in the blood samples. Compared with traditional paper spray, PDMS-printed paper spray (PP-PS) allows fluid to flow to the tip of paper with less sample loss which significantly improved the signal intensity of target compounds in blood samples. As paper can reduce the matrix effect, PP-PS also has a greater advantage than electro-spray Ionization (ESI) when directly analyzing complex biological sample in terms of the detection efficiency. Linearity and limits of detection (LOD) were evaluated for five psychotropic drugs: olanzapine, quetiapine, 9-hydroxyrisperidone, clozapine, risperidone. As a result, PP-PS improved the signal intensity of the psychotropic drugs at a concentration of 250 ng/ml in blood samples by a factor of 2-5 times and lowered the relative standard deviation (RSD) by a factor of 2-5.6 times compared with traditional paper spray. And PP-PS also improved signal intensity by a factor of 9-33 times compared with ESI. Quantitative experiments of PP-PS mass spectrometry indicated that the linear range was 5-500 ng/ml and the LOD were improved by a factor of 5-71 times for all these drugs compared with traditional paper spray. In addition, PP-PS was applied to the home-made miniaturized mass spectrometer and the precursor ions of all five psychotropic drugs (250 ng/ml) in the mass spectrometry results were obtained as well. These could prove that PP-PS has the potential to analyze complex biological samples in application on the miniaturized mass spectrometer which can be used outside the laboratory., Competing Interests: Declaration of competing interest The authors declare no conflict of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript, or in the decision to publish the results., (Copyright © 2024 Elsevier B.V. All rights reserved.)
- Published
- 2024
- Full Text
- View/download PDF