1. Development and Validation of a Low-Cost, High-Fidelity Simulation Model for Robotic Internal Mammary Artery Harvest Using the da Vinci Xi Robot.
- Author
-
Ashraf SF, Seese L, Hasan IS, Babu AN, Balkhy HH, Kiaii BB, Guy TS, Kaczorowski DJ, and Bonatti J
- Subjects
- Humans, Animals, Tissue and Organ Harvesting education, Tissue and Organ Harvesting methods, Tissue and Organ Harvesting instrumentation, Tissue and Organ Harvesting economics, Coronary Artery Bypass education, Coronary Artery Bypass methods, Coronary Artery Bypass economics, Coronary Artery Bypass instrumentation, Cattle, Simulation Training methods, Simulation Training economics, Models, Anatomic, Robotic Surgical Procedures education, Robotic Surgical Procedures economics, Robotic Surgical Procedures methods, Mammary Arteries surgery
- Abstract
Objective: We created and validated a low-cost simulation model for robotic internal mammary artery (IMA) takedown., Methods: The simulation model utilized a calf fetus thorax cavity stented open internally and secured to a table. The simulation model was validated at a 2-day robotic cardiac surgery workshop. Each participant harvested one IMA using the da Vinci Xi robot (Intuitive Surgical, Sunnyvale, CA, USA). We compared participant self-reported confidence at robotic IMA harvest before and after using the simulator., Results: Our novel thorax-securing strategy resulted in a stable structure and allowed access to both IMAs from the same 3 ports. The cost to set up the first simulation model was $176 and $133 for every subsequent model. Fifty participants used the simulation model: 42 cardiothoracic surgery attendings and 8 fellows or residents. The feedback form response rate was 78% ( n = 39). On the Likert scale, participants rated realism of the calf model to simulate robotic IMA harvesting (0 = not realistic , 10 = highly realistic ) with a median of 8 out of 10 (interquartile range [IQR] 7 to 9). Participant confidence (0 = not at all confident , 10 = very confident ) in robotic IMA harvesting before and after using the simulator increased ( P = 0.001) from a median of 5 (IQR 1 to 7) to 9 (IQR 7 to 10)., Conclusions: This robotic IMA harvest simulation model is affordable, realistic, and improved participant confidence in robotic IMA harvest. It may provide a valuable training tool for surgeons learning robotic coronary bypass surgery and allows for training frequency necessary to pass basic learning curves., Competing Interests: Declaration of Conflicting InterestsThe authors declared the following potential conflicts of interest with respect to the research, authorship, and/or publication of this article: T.S.G. is a consultant for Edwards Lifesciences and Medtronic and case observation site and proctor for Intuitive Surgical.
- Published
- 2024
- Full Text
- View/download PDF