1. Safety, feasibility, and effectiveness of a CT-guided transthoracic lung and pleural biopsy - a single-centre experience with own low-dose protocol.
- Author
-
Guzinski M, Puła M, Zdanowicz A, Kacała A, Dudek K, Lipiński A, and Sąsiadek M
- Abstract
Purpose: To assess the efficacy and safety of a low-dose, computed tomography (CT)-guided transthoracic biopsy of lung and pleural lesions., Material and Methods: A total of 135 low-dose, CT-guided transthoracic lung and pleural lesions biopsies were performed. A cutting needle was utilized in 124 cases, and fine needle aspiration biopsy was performed in 14 cases. In all cases, 14- to 22-gauge biopsy needles were used., Results: Diagnostic material was obtained in 111 (82.2%) patients. In 97 (71.8%) cases neoplastic lesions were found, predominantly adenocarcinoma and non-small cell carcinoma. In 14 (12.6%) cases non atypical cells were reported. Biopsy failed to obtain material suitable for histopathological examination in 24 (17.7%) cases. Complications occurred in 31 patients, including pneumothorax in 28 patients and haematoma in 3 cases., Conclusions: Based on the obtained results, it can be stated that low-dose, CT-guided transthoracic biopsy of lung and pleural tissues is an accurate and safe procedure. Also, it is linked to a low risk of complications such as a small pneumothorax., Competing Interests: The authors report no conflict of interest., (© Pol J Radiol 2023.)
- Published
- 2023
- Full Text
- View/download PDF